HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 362
SMX_SAStoragePool Class
The SMX_SAStoragePool class implements the HPSA_StoragePool class and represents any concrete
storage pools created on an array controller. There is one instance per array system.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
ElementName
Controller name and <physical location>.
Refer to “Physical Location” for more information.
For example:
“Smart Array in Slot=3” for internal
For example:
“Smart Array Embedded Controller=7” for embedded
controller where 7 is the internal identifier for the embedded
controller.
CIM_ManagedSystemElement
CIM_LogicalElement
CIM_StoragePool
InstanceID
Opaque key
PoolID
Controller serial number: <n> where n is the array
number as supplied from API.
Primordial
Always set to FALSE
RemainingManagedSpace
Remaining raw space in current pool
TotalManagedSpace
Total raw space managed by this pool
HPSA_StoragePool
SMX_SAMediaAccessStatData Class
The SMX_SAMediaAccessStatData class implements the HPSA_MediaAccessStatData and represents
the Monitoring and Performance data counters on HP Disk Drives.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
CIM_StatisticalData
InstanceID
Opaque key
SampleInterval
00000000000000.000000:000
CIM_MediaAccessStatData
HPSA_MediaAccessStatData