HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 368
Property Name Property Implementation
CIM_ManagedElement
ElementName
Controller name and <physical location>.
Refer to “Physical Location” for more information.
For example:
“Smart Array in Slot=3” for internal
For example:
“Smart Array Embedded Controller=7” for embedded
controller where 7 is the internal identifier for the embedded
controller.
CIM_ManagedSystemElement
OperationalStatus[0]
Operational status of the controller
0 (Unknown)
2 (OK)
6 (Error)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
CIM_LogicalDevice
CreationClassName SMX_SASCSIProtocolController
DeviceID
Opaque key
SystemCreationClassName SMX_SAArraySystem
SystemName SMX_SAArraySystem.Name
CIM_ProtocolController
MaxUnitsControlled 32
CIM_ SCSIProtocolController
HPSA_ SCSIProtocolController
SMX_SAStorageRedundancySet Class
The SMX_SAStorageRedundancySet class implements the HPSA_StorageRedundancySet class and
represents disk sparing aspect of a RAID configuration. There is an instance for every logical drive that has
spare drives configured.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement