HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 372
Property Name Property Implementation
ElementLocationTagDesc.
ElementLocationTagDesc
20 (Bay)– when firmware supports Bay numbering
HPSA_DiskDriveLocation
SMX_SAArrayControllerLocation Class
The SMX_SAArrayControllerLocation class implements the HPSA_ArrayControllerLocation class
and represents a location string for the array controller.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
Caption
Smart Array in <physical location>
Refer to “Physical Location” for more information.
Description
Same as Caption.
ElementName
Same as Caption.
CIM_Location
Name
Opaque key
PhysicalPosition
Opaque key
HP_Location
ElementLocationTag
For Internal HBA’s:
PCI Slot Number
For example:
3 – for adapter in PCI Slot 3
For example:
0 – for Embedded adapter
ElementLocationTagDesc
23 (Adapter) – for Internal HBA’s
LocationInformation[0]
Array of text values representing the location components
that describe this Ethernet Controller Physical location.
LocationInfoDesc[0] per LocationInfornation[0].
Refer to the LocationInfoDescription array to determine
what type of location information is represented.
LocationInfoDesc[0]
1(MezzanineSlot)—for internal HBA on a Mezzanine
Card
3 (PCI Slot) – for internal HBA in a PCI slot
17(Embedded Device) – for internal HBA embedded on
Motherboard
HPSA_ArrayControllerLocation