HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 374
Property Name Property Implementation
NoSinglePointOfFailureDefault
True - When number of drives > 1
(For example: Pool can be configured for redundancy)
False – When number of drives <= 1
PackageRedundancyDefault
0 (When number of drives <= 1)
1 (When number of drives = 2 or 3)
2 (When number of drives > 3)
PackageRedundancyMax
0 (When number of drives <= 1)
1 (When number of drives = 2 or 3)
2 (When number of drives > 3)
PackageRedundancyMin 0
HPSA_StorageCapabilities
SMX_SAProduct Class
The SMX_SAProduct class implements the HPSA_Product class and represents the top level marketing
information for the array system.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
ElementName
Controller name and <physical location>.
Refer to “Physical Location” for more information.
For example:
“Smart Array in Slot=3” for internal
For example:
“Smart Array Embedded Controller=7” for embedded
controller where 7 is the internal identifier for the embedded
controller.
CIM_Product
IdentifyingNumber
Opaque key
Name
String representing the Marketing name.
Vendor HP
Version
Firmware version of HBA or Storage System.
HPSA_Product