HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Manager WBEM Base Server Provider Overview 37
Property Name Property Implementation
DeviceModel
Enclosure Model string
HP_DeviceIndication: Enclosure Power Supply Status changed
to OK (Redundant)
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2 (Info)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Power Subsystem has changed to
Fully Redundant.
AlertingManagedElement
WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 302
EventTime
Time of the event or time of the indication if event time unknown
ProviderName HP Smart Array
RecommendedActions No action is recommended.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary Redundant power supply status OK
EventCategory
17 (Primary Storage Power)
ProbableCause
1 (Other)
ProbableCauseDescription Redundant Power Supply Status Changed to OK
NetworkAddresses
Contains a list of all the IP addresses of the computer system
generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion
The operating system version of the computer system generating the
indication in the following format: <major>.<minor>.<build>
ProviderVersion
For example:
2.2.0.0
SystemFirmwareVersion
Firmware version of the computer system generating the indication
SystemSerialNumber
Serial number of the computer system generating the indication