HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 391
AvailableSAP SMX_SATSASSCSIProtocolEndpoint
ManagedElement SMX_SADiskDrive
SMX_SASCSIInitiatorTargetLogicalUnitPath
The following table lists the associations implemented for this class.
Property Name Property Implementation
Initiator SMX_SAISASSCSIProtocolEndpoint
Target SMX_SATSASSCSIProtocolEndpoint
LogicalUnit SMX_SAStorageExtent
State
0 (Unknown) if path status cannot be ascertained
2 (active) if the path is active and healthy
5 (path error) if the path has an error
3 (passive) path is healthy but is not active or
is the standby path
SMX_SAPortControllerPCIDevice (Association)
The following table lists the associations implemented for this class.
Property Name Property Implementation
SystemElement SMX_PCIDevice
SameElement SMX_SAPortController
Provider Indications
Indications Generated
by the Provider
The following tables describe the SMX WBEM Smart Array Provider indications
that are implemented for HP ProLiant server platforms where available.
HP_DeviceIndication: Physical Drive Status Changed to OK
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2 (Informational)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive status has changed from a non-
OK state to OK.
AlertingManagedElement
WBEM Path of SMX_SADiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 201