HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 393
Property Name Property Implementation
RackName *
Rack name if, one exists
RackUID *
Rack Unique Identifier, if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualUUID
Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion
Physical Disk firmware version string
HWLogicalLocation
Physical Disk Location string
For example:
Port:1E Box: 1 Bay 5
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
HWSerialNumber
Physical Disk Serial Number
HP_DeviceIndication
DeviceModel
Physical Disk Model string
DeviceControllerLogicalLocation
Controller Location
For example:
SmartArray 642 in Slot 2
VariableNames[]
FailureDescription
DriveInterface
LastFailureDescription
VariableTypes[]
String (1)
uint16 (4)
VariableValues[]
FailureDescription – short description of the failure
Drive interface HPSA_DiskDrive.DriveInterface
LastFailureDescription – last failure reason string
from the drive.
HPSA_DiskDrive.OperationalStatus[1]
HP_DeviceIndication: Physical Drive Status Changed to ERROR
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
Severity
5 (Major)