HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 394
Property Name Property Implementation
IndicationTime
Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Error.
AlertingManagedElement
WBEM Path of SMX_SADiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 202
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP Smart Array (
RecommendedActions Check for failed or removed physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary Physical drive status Error
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription Physical Drive Status Changed to Error
NetworkAddresses
Contains a list of all the IP addresses of the computer system
generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion
For example:
2.2.0.0
SystemFirmwareVersion
Firmware version of the computer system generating the
indication
SystemSerialNumber
Serial number of the computer system generating the
indication
SystemProductID
Product ID of the computer system generating the indication
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication