HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 397
Property Name Property Implementation
indication
SystemProductID
Product ID of the computer system generating the indication
SystemModel
Model name of the computer system generating the
indication
SystemGUID
Platform GUID of the computer system generating the
indication
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note:
When ImpactedDomain is 3 (Enclosure) the properties that
follow and are indicated with an asterisk (*) below will be
populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName *
Rack name, if one exists
RackUID *
Rack Unique Identifier, if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualUUID
Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion
Physical Disk firmware version string
HWLogicalLocation
Physical Disk Location string
For example:
Port:1E Box: 1 Bay 5
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
HWSerialNumber
Physical Disk Serial Number
VariableNames[]
FailureDescription
DriveInterface
LastFailureDescription
VariableTypes[]
String (1)
uint16 (4)