HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 405
SMX_SAStorageVolumeIndication: Logical Drive Status
Changed to Degraded
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2 (Info)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A logical drive is in a degraded state. Device
is still servicing I/O but redundancy may be
degraded or lost.
AlertingManagedElement
WBEM Path of SMX_SAStorageVolume class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 103
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP Smart Array
RecommendedActions
Check status of physical drives. Degraded status
may be caused by failed or missing physical
drives, or a data recovery operation on one or
more physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary Logical drive in degraded state
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription Logical State Changed to Degraded
NetworkAddresses
Contains a list of all the IP addresses of the computer system
generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion
For example:
2.2.0.0
SystemFirmwareVersion
Firmware version of the computer system generating the
indication