HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 413
Property Name Property Implementation
VariableNames[]
FailureDescription
CacheSizeTotal
CacheSerialNumber
VariableTypes[]
String (1)
uint32 (5)
VariableValues[]
FailureDescription – short description of the failure
CacheSizeTotal
HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel
Array Controller Model string
HP_DeviceIndication: Controller Battery Status Changed to not
fully charged
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Smart Array controller Battery status has changed to
Not Fully Charged.
AlertingManagedElement
WBEM Path to SMX_SAArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 7
EventTime
Time of the event or time of the indication if event time unknown
ProviderName HP Smart Array
RecommendedActions
Check battery operation, allow time to the battery to
be fully charged.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary Controller Battery Status set to Not fully Charged.