HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 423
Property Name Property Implementation
HWSerialNumber
Array Controller Serial Number
VariableNames[]
FailureDescription
CacheSizeTotal
CacheSerialNumber
VariableTypes[]
String (1)
uint32 (5)
VariableValues[]
FailureDescription – short description of the failure
CacheSizeTotal
HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel
Array Controller Model string
HP_DeviceIndication: Enclosure Power Supply Status changed
to Non Redundant
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Power Subsystem status has changed
to non-redundant.
AlertingManagedElement
WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 301
EventTime
Time of the event or time of the indication if event time unknown
ProviderName HP Smart Array
RecommendedActions
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication