HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Manager WBEM System Fan Provider Overview 441
SMX_FanSlot
SMX_FanInSlot
SMX_SystemFanSlot
SMX_FanSpeedSensor
SMX_AssociatedFanSensor
SMX_SystemFanSensor
The tables in the following sections describe the properties of the supported classes. The classes are
categorized by the class or superclass that defines the property, the first column is the Property Name
(including type and units) and the second column describes how the provider determines the properties
implementation. When the Property Implementation value is a number, the number given is the default
behavior and the Managed Object Format interpretation is within parenthesis. If other values are returned,
a problem is indicated.
Unless otherwise noted, all of the property implementation values given are for HP ProLiant and HP Integrity
(cellular and non-cellular) systems. The location related properties and implementation values are
determined based on the server type so they may differ.
SMX_Fan Class
The SMX_Fan class is used to model fans on servers. Fan numbers for existing instances do not change when
other fans are added and removed.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
Caption
Short description of this fan from the name displayed by the MP or
iLO and the location.
For example:
Fan 1 at CabinetFan=01
Description
Description of this fan, including ElementName, FanType and
StatusDescription[0].
For example:
elementname provides cooling for fantype. statusdescription.
Where: <elementname> represents the value of ElementName,
fantype represents the corresponding string value of the FanType
enumeration and statusdescription represents the value of
StatusDescriptions[0]
ElementName
Short description of this fan from the name displayed by the MP or
iLO and the location.
For example:
Fan 1 at CabinetFan=01
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) – if fan is operating properly;
3 (Degraded) – if fan is degraded
6 (Error) – if fan has failed