HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Manager WBEM System Fan Provider Overview 442
Property Name Property Implementation
StatusDescriptions[0]
Description of the status of the fan corresponding to the
OperationalStatus.
For example:
Fan is operating properly– if OperationalStatus[0] is 2
(OK);
Fan is degraded – if OperationalStatus[0] is 3 (Degraded)
Fan has failed – if OperationalStatus[0] is 6 (Error)
HealthState
5 (OK) – if fan is operating properly;
10 (Degraded) - if fan is degraded
20 (Major Failure) – if fan has failed
Name
Short description of this fan from the name displayed by the MP or
iLO and the location.
For example:
Fan 1 at CabinetFan=01
CIM_LogicalDevice
CreationClassName SMX_Fan
DeviceID
Unique identifier for this fan instance.
SystemCreationClassName SMX_ComputerSystem.CreationClassName
SystemName SMX_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
CIM_CoolingDevice
ActiveCooling TRUE
CIM_Fan
VariableSpeed
True – if fan supports variable speed
False – if fan does not support variable speed or is unknown
HP_Fan
FanType
Enumeration describing the type of fan. Please refer to the Managed
Object Format.
CurrentSpeed
Speed of the fan in CurrentSpeedUnits
CurrentSpeedUnits
Enumeration describing the units for CurrentSpeed. Please refer to
the Managed Object Format.
SMX_FanCollection Class
The SMX_FanCollection class is used to model fan collections on servers. There is one instance of this
class on systems modeling fans.