HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Manager WBEM System Fan Provider Overview 446
The following table lists the properties implemented.
Property Name Property Implementation
GroupComponent
References HP_ComputerSystem
PartComponent
References HP_Fan
SMX_FanLocation Class
The SMX_FanLocation class is used to model fan locations on servers.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
Caption
Short description of this fan location, including the name displayed by
the MP or iLO.
For example on HP ProLiant:
Fan 1 at CabinetFan=01
Description
Description of this fan location, including the name displayed by the
MP or iLO.
For example on HP ProLiant:
The location of the Fan 1. Please refer to the fan
position CabinetFan=01 printed on the system.
ElementName
User displayable name of this fan location, including the name
displayed by the MP or iLO.
For example on HP ProLiant:
Fan 1 at CabinetFan=01
CIM_Location
Name
Unique identifier for this fan location instance.
PhysicalPosition
Opaque identifier for the physical position of this fan
HP_Location
ElementLocationTag
Location string based on ElementLocationTagDesc.
For example, on HP ProLiant:
CabinetFan=01
ElementLocationTagDesc
On HP ProLiant: 0 (HoodTag)
LocationInfoDesc
Array of location descriptions: On ProLiant: 4 (Socket)
LocationInformation
Array of string descriptions of the location based on
LocationInfoDesc