HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Manager WBEM System Fan Provider Overview 448
Property Name Property Implementation
StatusDescriptions[0]
Description of the status of the fan corresponding to the
OperationalStatus.
For example:
Fan is operating properly – if OperationalStatus[0] is 2 (OK);
Fan is degraded – if OperationalStatus[0] is 3 (Degraded)
Fan has failed – if OperationalStatus is 6 (Error)
HealthState
5 (OK) – if fan is operating properly;
10 (Degraded) if fan is degraded
20 (Major Failure) – if fan has failed
Name
Name of this fan module.
For example:
Fan 1 at CabinetFan=01
CIM_PhysicalElement
CreationClassName SMX_FanModule
Tag
Unique identifier for this fan instance.
CIM_PhysicalPackage
RemovalConditions
0 (Unknown)
3 (Removable when off)
4 (Removable when on or off)
PackageType
7 (Fan)
SMX_SystemPhysicalFan Class
The SMX_SystemPhysicalFan class implements the HP_SystemPhysicalFan class and association the
HP_ComputerSystemChassis instance with HP_FanModule.
The following table lists the properties implemented.
Property Name Property Implementation
GroupComponent
References HP_ComputerSystemChassis
PartComponent
References HP_FanModule
SMX_RealizesFan Class
The SMX_RealizesFan class implements the HP_RealizesFan class and associates the HP_Fan instance
with HP_FanModule instances.
The following table lists the properties implemented.
Property Name Property Implementation