HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Manager WBEM System Fan Provider Overview 452
SMX_AssociatedFanSensor
SMX_AssociatedFanSensor is used to represent an association between HP_Fan and the
SMX_FanSpeedSensor that is reporting the speed of the fan.
Property Name Property Implementation
Antecedent
References SMX_FanSpeedSensor
Dependent
References SMX_Fan
Provider Indications
Indications Generated
by the Provider
The following tables describe the SMX WBEM System Fan Provider indications
that are implemented for HP ProLiant server platforms, where available.
Note: Some HP ProLiant servers do not support Fan Degraded or Fan Redundancy Failed indications.
Provider Indication Common Properties
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication.
IndicationTime
Time of indication.
CIM_AlertIndication
EventTime
Time of the event or time of the indication if event time
unknown.
SystemName SMX_ComputerSystem.Name
SystemCreationClassName SMX_ComputerSystem.CreationClassName
HP_AlertIndication
ProviderVersion
Provider Version in the format VV.UU.FF.
For example:
01.05.00
NetworkAddresses
Contains a list of all the IP addresses of the computer system
generating the indication.
OSType
On ESX, 39 (VM)
On Linux, 36 (Linux)
OSVersion
The operating system version of the computer system generating
the indication in the following format: major.minor.build
SystemFirmwareVersion
Array of firmware versions of the computer system generating
the indication.
SystemSerialNumber
Serial number of the computer system generating the indication.
SystemProductID
Product ID of the computer system generating the indication.
SystemModel