HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Manager WBEM System Fan Provider Overview 455
Property Name Property Implementation
ProbableCause
94 (Fan Failure)
ProbableCauseDescription Fan Failed
HP_DeviceIndication: Fan Repaired
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description
A fan has been repaired. The fan is now operating properly.
<FanCaption>
Where: <FanCaption> is the SMX_Fan.Caption for the fan that has
been repaired.
AlertingManagedElement
WBEM Path of SMX_Fan instance representing the failed fan.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 4
ProviderName HP Cooling
RecommendedActions No action is recommended.
HP_AlertIndication
Summary Fan repaired
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription Fan Repaired
HP_DeviceIndication: Fan Degraded
.
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
4 (Minor)
CIM_AlertIndication
Description
A fan has degraded. <FanCaption>
Where: <FanCaption> is the SMX_Fan.Caption for the fan that has
degraded.
AlertingManagedElement
WBEM Path of SMX_Fan instance representing the degraded fan.