HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Manager WBEM System Fan Provider Overview 456
Property Name Property Implementation
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 9
ProviderName HP Cooling
RecommendedActions Check the degraded fan and replace if necessary.
HP_AlertIndication
Summary Fan degraded
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription Fan Degraded
HP_DeviceIndication: Fan Redundancy Reduce
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description
A fault tolerant fan is no longer providing cooling for a cooling
redundancy set. <RedundancySetCaptio>)
Where: <RedundancySetCaption> represents the
SMX_FanRedundancySet.Caption for the redundancy set with
reduced redundancy.
AlertingManagedElement
WBEM Path of SMX_FanRedundancySet instance representing the
redundancy set with reduced redundancy.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 5
ProviderName HP Cooling
RecommendedActions No action is recommended.
HP_AlertIndication
Summary Cooling redundancy reduced
EventCategory
23 (System Cooling)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription Cooling Redundancy has been Reduced
DeviceIndication: Fan Redundancy Lost
Property Name Property Implementation
CIM_Indication