HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Manager WBEM System Fan Provider Overview 458
Property Name Property Implementation
HP_AlertIndication
Summary Cooling redundancy restored
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription Cooling Redundancy has been Restored
HP_DeviceIndication: Fan Redundancy Failed
Important:
This indication is not supported on HP ProLiant systems because redundancy set failure, which is failure
beyond redundancy lost, will cause system shutdown.
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description
Cooling redundancy for the system has failed.
(RedundancySetCaption)
Where: RedundancySetCaption is
SMX_FanRedundancySet.Caption of the cooling redundancy set
with failed redundancy.
AlertingManagedElement
WBEM Path of SMX_FanRedundancySet instance representing the
cooling redundancy set with failed redundancy.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 10
ProviderName HP Cooling
RecommendedActions
Check the fan configuration and check the status of the
cooling redundancy. Ensure the system is being cooled
adequately. Add or replace fans if necessary.
HP_AlertIndication
Summary Cooling redundancy set failed
EventCategory
23 (System Cooling)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription Cooling Redundancy Set has Failed