HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM System Memory Provider 464
Property Name Property Implementation
property is IsSpeedInMhz=TRUE.
MaxMemorySpeed
The maximum speed in MHz of PhysicalMemory
MemoryType
Enumerator indicating the type of memory module.
Refer to MOF file for details.
PositionInRow
Position of memory module in a row. This property is conditional; it is
populated if the data is available
FormFactor
Enumerator indicating the form factor of the memory module.
Refer to MOF file for details.
For example:
8 (DIMM)
BankLabel
String identifying the physically labeled bank where the memory is
located.
For examples:
'DIMM 0A' or 'PROC 1 DIMM 0A' or 'Board 1,0A' or 'Board 1,
DIMM 1A
(Upper Tray, Riser 1)'
This property is conditional; it is populated if the data is available.
SMX_MemoryModule
Spd
An array that contains raw Serial Presence Detect information for the
memory module. Each array element contains a byte of the Spd.
This property is conditional; it is populated if the data is available.
Properties for Memory Module Status
Condition
OperationalStatus[0] OperationalStatus[1]
StatusDescriptions[0
]
StatusDescriptions[1]
Memory module status is
unknown
0 (Unknown)
<not populated>
Unknown <not populated>
Memory module is
operating properly
2 (OK)
<not populated>
OK <not populated>
Memory module is
present but is not
currently used by the
operating system
2 (OK) 15 (Dormant)
OK
Memory module status: Memory present
but not in use
Memory module has
correctable errors
exceeding the condition
for pre-failure warranty
3 (Degraded) 5 (Predictive Failure)
Degraded
Memory module status: Correctable
error threshold for pre-failure
warranty has been exceeded