HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM System Memory Provider 470
Property Name Property Implementation
CIM_Container
HP_MemoryModuleSlotOnBoard
SMX_MemoryModuleSlotOnBoard
GroupComponent
References SMX_MemoryBoard
PartComponent
References SMX_MemoryModuleSlot
SMX_MemoryModuleSlotLocation Class
The SMX_MemoryModuleSlotLocation class extends the CIM_Location class and represents memory
module slot locations on HP servers. There is an instance of this class for each memory module slot in the
system (whether the slot is occupied or not).
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
Caption
Memory Module Socket Location <physical location>.
Refer to “Physical Location” for more information.
Description
Memory Module Socket Location <physical location>.
Refer to “Physical Location” for more information.
ElementName
Memory Module Socket Location <physical location>.
Refer to “Physical Location” for more information.
CIM_Location
Name
Opaque key of the format:
HPQ:SMX_MemoryModuyleSlotLocation:<Key 1>: <Key 2>: ...etc.
PhysicalPosition
Opaque key.
Example for memory socket number 2 on cpu, board, or cartridge
number 1:
FF-FF-FF-FF-01-02-FF-79
HP_Location
ElementLocationTag
Opaque key.
Example for memory socket number 2 on cpu, board, or cartridge
number 1:
FF-FF-FF-FF-01-02-FF-79
ElementLocationTagDesc
8 (Memory Module)
LocationInformation
Indexed array: LocationInformation[0] per
LocationInformationDesc[0].
Location information will contain a numeric string representing the
unique location identifier of each object type described by the
corresponding LocationInfoDesc index.