HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM System Memory Provider 474
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
Caption Memory Redundancy Set
Description Memory Redundancy Set for Advanced Memory Protection
ElementName Memory Redundancy Set
CIM_SystemSpecificCollection
InstanceID HPQ:SMX_MemoryRedundancySet:001
CIM_RedundancySet
TypeOfSet
Represents the type of redundancy currently in operation for the
Advanced Memory Protection system. This property corresponds
functionally to the property CurrentConfiguration.
TypeOfSet[0] contains the current type of redundancy:
1 (Other), when the system is operating in Advanced ECC or Lockstep
mode
2 (N+1), when the system is operating in RAID (XOR) mode
3 (Load Balanced), when the system is operating in Mirrored mode
4 (Sparing), when the system is operating in Online Spare mode
OtherTypeOfSet
OtherTypeOfSet[0] contains the type of redundancy when the
property TypeOfSet[0] = 1 (Other). In this case, the property will
contain the value Advanced ECC or Lockstep, otherwise the property
is not populated.
LoadBalanceAlgorithm
2 (No Load Balancing)
RedundancyStatus
Represents the current memory redundancy status as follows:
2 (Fully Redundant)
System is operating properly in the Advanced Memory Protection
mode given in the TargetConfiguration property.
3 (Degraded Redundancy)
Degraded Redundancy can occur in either of the following conditions:
System is not operating in the TargetConfiguration mode (the
CurrentConfiguration mode does not match the
TargetConfiguration mode).
System is operating in the TargetConfiguration mode but
memory module(s) have correctable errors exceeding the condition for
pre-failure warranty.
HP_MemoryRedundancySet
OperatingSpeed
The current operating speed of the Advanced Memory Protection
subsystem in MHz
AvailableMemory
The size of the memory as seen by the operating system in MB