HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM CPU Provider Overview 70
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
Caption
Level <x> Data Cache where <x> is the cache level number
Level <x> Instruction Cache where <x> is the cache level
number
Level <x> Unified Cache where <x> is the cache level number
For example:
Level 1 Data Cache
Level 2 Unified Cache
Description
Level <x> Data Cache where <x> is the cache level number
Level <x> Instruction Cache where <x> is the cache level
number
Level <x> Unified Cache where <x> is the cache level number
For example:
Level 1 Data Cache
Level 2 Unified Cache
ElementName
Level <x> Data Cache where <x> is the cache level number
Level <x> Instruction Cache where <x> is the cache level
number
Level <x> Unified Cache where <x> is the cache level number
For example:
Level 1 Data Cache
Level 2 Unified Cache
CIM_ManagedSystemElement
OperationalStatus
0 (Unknown)
2 (OK), when CPU is enabled and operational
5 (Predictive Failure), when IML error info logged for this CPU
6 (Error), when CPU is disabled via POST error
10 (Stopped), when CPU is disabled via RBSU
StatusDescriptions
StatusDescriptions[0] text per OperationalStatus[0]:
Unknown
OK
Stopped
Error
Predictive Failure
HealthState
0 (Unknown), when OperationalStatus[0]=0 (Unknown)
5 (OK), when OperationalStatus[0]=2 (OK)
15 (Minor Failure), when OperationalStatus[0]=10 (Stopped)
20 (Major Failure), when OperationalStatus[0]=5 (Predictive
Failure)
25 (Critical Failure), when OperationalStatus[0]=6 (Error)