HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM CPU Provider Overview 82
Physical Location
The Processor Physical Location is a string representing the physical location of a physical CPU module or
chip. This string should represent the physical location of the device with which an end-user can uniquely
locate the device. Most of these strings will be represented in customer documentation, silkscreen labels, or
hood tags.
The following table lists the properties implemented. Any combination of the following applicable
descriptors could be used to better define the device location.
All Systems HP Integrity Cellular Servers
HP Blade Servers in
C3000/C7000 Enclosures
CPUSocket=<socket_num> on
System Mainboard
Cabinet=<cell_or_blade_cabi
net_num>
_
ProcessorBoard=<board_num>
Cell=<cell_num>
Blade=<blade_num>
System Mainboard(referring to
motherboard)
_ _
CPUSocket=<socket_num> on
ProcessorBoard=<board_num>
_ _
Provider Indications
Indications Generated by the
Provider
The SMX CPU Provider generates WBEM indications described in the
following sections.
Note
These Indications only apply to Proliant Servers.
Common Properties for Provider Indications
The following table describes the properties that are common to all of the SMX CPU Provider indications
that are implemented for HP server platforms where available:
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication.
IndicationTime
Time of indication.
CIM_AlertIndication
EventTime
Time of the event or time of the indication if event time unknown.
SystemName SMX_ComputerSystem.Name
SystemCreationClassName SMX_ComputerSystem.CreationClassName
HP_AlertIndication
ProviderVersion
Provider Version in the format VV.UU.FF.
For example:
01.05.00