HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM CPU Provider Overview 83
Property Name Property Implementation
NetworkAddresses
Contains a list of all the IP addresses of the computer system
generating the indication.
OSType
On ESX, 39 (VM).
On Linux, 36 (Linux).
OSVersion
The operating system version of the computer system generating the
indication in the following format: <major>.<minor>.<build>
SystemFirmwareVersion
Array of firmware versions of the computer system generating the
indication.
SystemSerialNumber
Serial number of the computer system generating the indication.
SystemProductID
Product ID of the computer system generating the indication.
SystemModel
Model name of the computer system generating the indication.
SystemGUID
Platform GUID of the computer system generating the indication.
HP_DeviceIndication: Processor Failed POST
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
4 (Minor)
CIM_AlertIndication
Description CPU Failed Power on Self Test (POST)
AlertType
5 (Device Alert)
EventID 1
EventCategory
2 (Processor)
ProviderName HP Processor
RecommendedActions Replace the failed processor
HP_AlertIndication
Summary CPU Failed Power on Self Test (POST)
ProbableCause
1 (Other)
HP_DeviceIndication: Processor Disabled by BIOS or EFI
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
4 (Minor)
CIM_AlertIndication
Description CPU has been disabled by BIOS or EFI
AlertType
5 (Device Alert)
EventID 2