HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.
1 HP Insight Manager WBEM Base Server Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Base Server provider implements and extends CIM classes described in this document to model the base server. These classes provide computational information and capabilities and serve as an aggregation point to associate one or more elements that make up a base server, such as: Fans, PowerSupplies, Processor and Memory (Volatile and/or NonVolatile Storage).
Release History Initial release with HP Insight Management WBEM Providers for Linux v2.0. 1-1 Setting Up the Provider Installing the Provider part of the HP Insight Management WBEM providers. Configuring the Provider This provider does not accept specific configuration adjustments beyond standard HP Insight Management WBEM support. 1-2 There are no special installation instructions for this provider.
Unless otherwise noted, all of the property implementation values given are for HP ProLiant and HP Integrity (cellular and non-cellular) systems. The location related properties and implementation values are determined based on the server type so they may differ. 1-2-1 SMX_ComputerSystem Class The SMX_ComputerSystem class implements the HP_ComputerSystem class to model the base server. There is only one instance of SMX_ComputerSystem instantiated on a server.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Computer system DNS name returned by uname. Description Computer system DNS name returned by uname. ElementName Computer system DNS name returned by uname. CIM_ManagedSystemElement Status Same as OperationalStatus[0]. OperationalStatus[0] contains the computer system consolidated status and indicates the worst status of any connected subsystem.
Property Name Property Implementation OperationalStatusClassNames[0] contains the computer system class name, SMX_ComputerSystem.CreationClassName. OperationalStatusClassNames The class name of the HP_GroupSystemSpecificCollection class for the subsystems that make up the overall operational status reported in OperationalStatus[1-n] are contained in OperationalStatusClassNames[1-n]. See the datasheets for each provider for the values of each class name.
Property Name Property Implementation These will be set to: Unknown OK Error Stopped Predictive Failure 0 (Unknown) 5 (OK) HealthState 10 (Degraded) 20 (Major Failure) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_System CreationClassName SMX_ComputerSystem HP Insight Manager WBEM Base Server Provider Overview 6
Property Name Roles Property Implementation Computer system roles string: initialized to not set. CIM_ComputerSystem OtherIdentifyingInfo[0]: Where: is the computer system physical GUID string. OtherIdentifyingInfo[1]: Where: is the computer system MAC address. OtherIdentifyingInfo[2]: : Where: is the computer system model string; and Serial_Number_String is the computer system physical serial number string.
Property Name Property Implementation IdentifyingDescriptions[0]: CIM:GUID IdentifyingDescriptions[1]: CIM:MAC IdentifyingDescriptions[2]: CIM:Model:SerialNumber IdentifyingDescriptions[3]: IdentifyingDescriptions CIM:Tag IdentifyingDescriptions[4] CIM:CorrelatableID IdentifyingDescriptions[5] HPQ:ProductID IdentifyingDescriptions[6] HPQ:SMXTarget Dedicated 0 (Not Dedicated) HP_ComputerSystem Name Computer system DNS name returned by uname.
Property Name Property Implementation SecondaryOwnerName Computer system secondary owner name string; initialized to not set. SecondaryOwnerPager Computer system secondary owner pager string; initialized to not set. State of the computer system Unit Identifier (UID) LED: 0 (Unknown) LocationIndicator 2 (On) 3 (Off) 5 (Alternating) SerialNumber The computer system physical serial number string. IdentifyingNumber The computer system physical GUID string.
Method Parameters: EventID, number of test event to send: 101 - Send Information Test Indication 102 - Send Warning Test Indication 103 - Send Critical Test Indication Return Values: SendTestIndication 0 - request to send indication successful 1 - method unsupported 2 - request to send indication failed 3 - provider is busy processing previously requested indication, try again 4 - EventID is not one of the defined values Exception: CIM_ERR_INVALID_PARAMETER - EventID is the wrong type, does not exist or
Property Name Property Implementation Manufacturer Computer manufacturer string. Model Computer system product name (model) string. SerialNumber Computer system physical serial number. UserTracking Computer system asset tag string (writable property; persistent across reboots). Name Computer system product name (model) string. Status OK StatusDescriptions Description of the state of the chassis, for example System is functional.
Property Name Property Implementation 0 (Unknown) RackMountable 1 (True) 2 (False) HP_ComputerSystemChassis Computer system product ID string ProductID For example: 123456-123. VirtualUUID[] If Synergy is enabled, this will contain the logical UUID for the system. VirtualSerialNumber[] If Synergy is enabled, this will contain the logical Serial Number for the system. Indicates the installed and enabled state of the Trusted Platform Module.
Property Name Property Implementation CIM_SystemPackaging CIM_ComputerSystemPackage PlatformGUID Computer system physical UUID value from SMBIOS. HP_ComputerSystemPackage Antecedent References SMX_ComputerSystemChassis Dependent References SMX_ComputerSystem SMX_ComputerSystemPackage 1-2-4 SMX_OperatingSystem Class The SMX_OperatingSystem class implements the CIM_OperatingSystem class to model the system operating system. There is only one instance of SMX_OperatingSystem instantiated on a server.
Property Name Property Implementation StatusDescriptions[0] will contain the value map string corresponding to OperationalStatus[0]: StatusDescriptions For example: OK Status OK HealthState 5 (OK) PrimaryStatus 1 (OK) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 0 (Unknown) EnabledDefault 2(Enabled) TransitioningToState 12 (Not Applicable) CIM_OperatingSystem CSName SMX_ComputerSystem.Name CSCreationClassName SMX_ComputerSystem.
Property Name Property Implementation On Linux, 36 (Linux) OSType On ESXi, 39 (VM) LocalDateTime Current time. LastBootUpTime Time when the operating system was last booted SMX_OperatingSystem 1-2-5 SMX_RunningOS Class The SMX_RunningOS class implements the CIM_RunningOS class and associates the SMX_ComputerSystem instance and an SMX_OperatingSystem instance. The following table lists the properties implemented.
GroupComponent References SMX_ComputerSystem SMX_InstalledOS 1-2-7 SMX_SMXSoftwareIdentity Class The SMX_SMXSoftwareIdentity implements the HP_SoftwareIdentity class to model the SMX software identification information. The following table lists the properties implemented.
Property Name Property Implementation SMX is installed properly Status OK HealthState 5 (OK) CIM_LogicalElement CIM_SoftwareIdentity Opaque string using HPQ as OrgID InstanceID For example: HPQ:SMX_SMXSoftwareIdentity-1. MajorVersion The first numeric value in the VersionString. MinorVersion The second numeric value in the VersionString. RevisionNumber The third numeric value in the VersionString. VersionString Version of SMX, for example: 02.00.00.
Property Name Property Implementation IdentityInfoValue[0] will contain the following for a full installation of the WBEM providers: HPQ:hp-smx IdentityInfoValue[0] will contain the following for a limited installation of IdentityInfoValue[] the WBEM providers: HPQ:hp-smx-limited IdentityInfoValue[1] will contain the following: System Management HP_SoftwareIdentity SMX_SMXSoftwareIdentity 1-2-8 SMX_SMXInstalledSoftwareIdentity Class The SMX_SMXInstalledSoftwareIdentity class implements the CIM_Install
Property Name Property Implementation CIM_ManagedElement A description of the firmware. For example, on HP ProLiant: System ROM Firmware-() () where family_code is the system ROM family code and state is either Caption Active or Redundant. For example: System ROM Firmware-P31 (Active) System ROM Firmware-P31 (Redundant) Description A description of the firmware. ElementName A description of the firmware. CIM_ManagedSystemElement Name A name for the firmware.
Property Name Property Implementation Where: is used to identify the instance. For example: HPQ:SMX_SystemFirmware:1 MajorVersion The firmware major version. MinorVersion The firmware minor version. VersionString The firmware version. Manufacturer HP Classifications 11 (Bios/FCode) ClassificationDescriptions System Firmware On HP ProLiant, this will contain: HPQ: Where: is the system ROM family code.
1-2-10 SMX_SystemInstalledFirmwareIdentity Class The HP_SystemInstalledFirmwareIdentity class extends the CIM_InstalledSoftwareIdentity class and associates the HP_ComputerSystem instance and a SMX_SystemFirmware instance. The following table lists the properties implemented.
The following table lists the properties implemented.
Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of the indication IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication ProviderVersion Provider Version in the format VV.UU.FF. For example: 01.05.
Property Name Property Implementation SystemGUID Platform GUID of the computer system generating the indication SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v.. 1-3-1 HP_DeviceIndication:WBEM Providers Started The following tables describe the SMX Base Server Provider indications that are implemented for all server platforms.
HP_DeviceIndication: WBEM Providers Informational Test Indication 1-3-2 Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Informational) CIM_AlertIndication Description This is an information test event. AlertType 5 (Device Alert) EventID 1 ProviderName HP Test RecommendedActions No action is recommended.
Property Name Property Implementation Description This is a warning test event. AlertType 5 (Device Alert) EventID 2 ProviderName HP Test RecommendedActions No action is recommended.
Property Name RecommendedActions Property Implementation No action is recommended. HP_AlertIndication Summary Test Event ProbableCause 1 (Other) ProbableCauseDescription Test Indication 1-3-5 HP_DeviceIndication: ASR Reboot Occurred Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description The system has rebooted from an Automatic Server Recovery (ASR) event.
Property Name Property Implementation ProbableCause 111 (Timeout) ProbableCauseDescription ASR reboot occurred 1-3-6 HP_DeviceIndication: Thermal Reboot Occurred Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description The system has rebooted from thernal shutdownevent. AlertType 5 (Device Alert) EventID 2 ProviderName HP Recovery RecommendedActions Replace any failed or removed fans.
1-3-7 HP_DeviceIndication: Fan Failure Reboot Occurred Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description The system has rebooted from fan failure shutdown event. AlertType 5 (Device Alert) EventID 3 ProviderName HP Recovery RecommendedActions Replace any failed or removed fans.
Property Name Property Implementation Description The system has rebooted from VRM failure shutdown event. AlertType 5 (Device Alert) EventID 4 ProviderName HP Recovery RecommendedActions Replace any failed or removed power supplies.
Property Name Property Implementation AlertType 5 (Device Alert) EventID 1 ProviderName HP Post RecommendedActions Determine the nature of the POST error and take corrective action.
1 HP Insight Management WBEM Blade System Lite Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Blade System Lite provider extends the management capability of referencing profiles by adding the capability to represent the Distributed Management Task Force (DMTF) Modular System Profile in HP specific ways. While this profile is based on the DMTF Modular System Profile, it does not conform to that profile.
Provider 1-2 Insight Management WBEM support. Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement A description of the class. For example, if enclosure name exists: Caption HP BladeSystem enclosure otherwise: HP BladeSystem enclosure A description of the class. For example, if enclosure name exists: Description HP BladeSystem enclosure otherwise: HP BladeSystem enclosure A description of the class.
Property Name Property Implementation StatusDescriptions[0] per OperationalStatus[0]: Server Blade Enclosure and Onboard Administrator status: Unknown StatusDescriptions Server Blade Enclosure and Onboard Administrator status: OK Server Blade Enclosure and Onboard Administrator status: Degraded Server Blade Enclosure and Onboard Administrator status: Error 0 (Unknown), enclosure status: Unknown 5 (OK), enclosure status: OK HealthState 10 (Degraded/Warning), enclosure status: Degraded 20 (Major Failure),
Property Name Property Implementation IdentifyingDescriptions[0]: HPQ:ProductID IdentifyingDescriptions IdentifyingDescriptions[1]: CIM:Model:SerialNumber OtherIdentifyingInfo[0]: Where: is the blade enclosure product ID. OtherIdentifyingInfo OtherIdentifyingInfo[1]: : Where: is the blade enclosure model string; and Serial_Number_String> is the blade enclosure serial number string.
1-2-2 SMX_BladeEnclosureCollection Class The SMX_BladeEnclosureCollection class implements the HP_BladeEnclosureCollection class to aggregate the enclosure’s group operational status. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Description A description of the class, for example: A collection of server blade enclosures with group aggregate status ElementName A name for the class, for example: Server Blade Enclosure Collection.
Property Name Property Implementation GroupStatusDescriptions[0] per GroupOperationalStatus[0]: Server Blade Enclosure and Onboard Administrator status: Unknown GroupStatusDescriptions Server Blade Enclosure and Onboard Administrator status: OK Server Blade Enclosure and Onboard Administrator status: Degraded Server Blade Enclosure and Onboard Administrator status: Error HP_BladeEnclosureCollection 1-2-3 SMX_BladeSystemComponent Class The SMX_BladeSystemComponent class implements the HP_BladeSystemCom
The following table lists the properties implemented. Property Name Property Implementation CIM_MemberOfCollection HP_MemberOfBladeEnclosureCollection Collection References HP_BladeEnclosureCollection Member References HP_BladeEnclosureCS 1-2-5 SMX_BladeEnclosureGroupHostedCollection Class The SMX_BladeEnclosureGroupHostedCollection class implements the HP_BladeEnclosureGroupHostedCollection class and associates the enclosure’s computer system instance to the blade enclosure collection instance.
Property Name Property Implementation CIM_ManagedElement Caption A caption for the class. For example: Server Blade Enclosure Firmware. Description A description for the class. For example: HP Server Blade Enclosure Firmware. ElementName OA CIM_ManagedSystemElement A description of the class.
Property Name Property Implementation VersionString String indicating the blade enclosure firmware version information. This property is the string translation of the content provided in the MajorVersion and MinorVersion properties.
The following table lists the properties implemented.
1-2-9 SMX_BladeCSLocation Class The SMX_BladeCSLocation class implements the HP_Location class and is used to model the server blade location within an enclosure.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement A description of the Blade location. For example: Caption Blade Computer System Bay Location Where: represents the blade bay slot position printed on the enclosure labeling. A description of the Blade location. For example: Description Blade Computer System Bay Location Where: represents the blade bay slot position printed on the enclosure labeling.
ElementLocationTag The computer system name. ElementLocationTagDesc 24 (Blade) LocationInformation[0]: LocationInformation The blade bay number within the enclosure. LocationInfoDesc[0]: LocationInfoDesc 14 (Blade Bay) 1-2-10 SMX_BladeCSElementLocation Class The SMX_BladeCSElementLocation class implements the HP_ElementLocation class and is used to represent an association between the CIM_Location and CIM_ManagedElement classes.
1 HP Insight Management WBEM Configuration Record Log Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Configuration (Config) Record Log provider implements the Configuration Snapshot Log on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Record Log Profile (P00109) HP WBEM TC 1.1.
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace. This provider supports the following classes: Schema Supported by the Provider • SMX_ConfigRecordLog • SMX_ConfigLogEntry • SMX_ConfigLogManagesRecord • SMX_ConfigUseOfLog The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation OperationalStatus[0] indicates the status of the Configuration Record OperationalStatus Log: 2 (OK) HealthState 5 (OK), when OperationalStatus[0]=2 (OK) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 12 (Not applicable) EnabledDefault 2 (Enabled) CIM_Log MaxNumberOfRecords 1 – Only the most recent snapshot of the configuration will be available.
ClearLog Refer to HP Record Log profile (P00109). UpdateConfig Refer to HP Record Log profile (P00109). 1-2-2 SMX_ConfigLogEntry Class The SMX_ConfigLogEntry class implements the HP_CommonLogEntry class to model logs records within the Configuration log. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Config record log entry. Description Config record log entry. ElementName Config record log entry.
Property Name Property Implementation MajorClass 21 (Config Snapshot) MinorClass 2 (None) 0 (Unknown) 36 (Linux) OSType 39 (VMware) SystemSerialNumber System serial number string from SMBIOS. SystemProductID System product ID string from SMBIOS. SystemModel System model number string from SMBIOS. SystemName Computer system name.
1-2-4 SMX_ConfigUseOfLog Class The SMX_ConfigUseOfLog class implements the HP_UseOfLog class and associates the instance of HP_ComputerSystem with the instance of HP_CommonRecordLog. The following table lists the properties implemented. Property Name Property Implementation CIM_Dependency CIM_UseOfLog HP_UseOfLog Antecedent Reference HP_CommonRecordLog. Dependent Reference HP_ComputerSystem. 1-3 Provider Indications Indications Generated by the Provider This provider generates no indications.
1 HP Insight Management WBEM CPU Provider Overview The HP Insight Management Web-Based Enterprise Management (WBEM) CPU provider implements and extends classes described in this document to model the system processors. Description This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP CPU Profile (P00106) HP WBEM TC 1.1.0 HP CPU Consolidated Status Profile (P00107) HP WBEM TC 1.0.
1-1 Setting Up the Provider Installing the Provider There are no special installation instructions for this provider. It is installed by default as part of the HP Insight Management WBEM providers. Configuring the Provider This provider does not accept specific configuration adjustments beyond standard HP Insight Management WBEM support. 1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
• SMX_SystemPhysicalProcessor • SMX_ProcessorLocation • SMX_ProcessorElementLocation The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name Property Implementation Manufacturer: Intel(R) Family: Xeon(TM) CPU 3.06GHz (x86 Family 15 Model 2 Stepping 7) Processor in ElementName For text representing the CPU location, refer to “Physical Location”. CIM_ManagedSystemElement Processor in Name For text representing the CPU location, refer to “Physical Location”.
Property Name Property Implementation 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), when OperationalStatus[0]=2 (OK) HealthState 15 (Minor Failure), when OperationalStatus[0]=10 (Stopped) 20 (Major Failure), when OperationalStatus[0]=5 (Predictive Failure) 25 (Critical Failure), when OperationalStatus[0]=6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice SystemCreationClassName
Property Name Property Implementation 1 (CPU Enabled) 2 (CPU Disabled by User using BIOS Setup) CPUStatus 3 (CPU Disabled By BIOS (POST Error)) 4 (CPU Idle) 7 (Other) Processor family number from SMBIOS Family For example, 179 for Intel(R) Xeon(TM) maximum clock speed in MHz MaxClockSpeed For example: 3600 current clock speed in MHz CurrentClockSpeed For example: 3066 32 – for x86 processors DataWidth 64 – for x64 processors 32 – for x86 processors AddressWidth 64 – for x64 processors external bus
Property Name Property Implementation For x86 processors: Characteristics[0] 3 (32-bit Capable) For x64 processors / x86_64 processors: Characteristics Characteristics[0] 3 (32-bit Capable) Characteristics[1] 2 (64-bit Capable) Number of enabled and operational cores for this processor NumberOfEnabledCores For example: 1, 2, 4 Stepping Stepping for processor Role Processor Role UniqueID Unique identifier for processor HP_Processor SMX_Processor 1-2-2 SMX_ProcessorCapabilities Class The SMX_Proc
Property Name Property Implementation Caption Processor Capabilities Description Processor Capabilities CIM_Capabilities HPQ:SMX_ProcessorCapabilities: InstanceID Where: is a unique number.
1-2-3 SMX_ProcessorCore Class The SMX_ProcessorCore class extends the CIM_ProcessorCore class to model the processor cores. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Processor:
Core: Caption Where: is the processor number and is the core number.
Property Name Property Implementation StatusDescriptions[0] text per OperationalStatus[0]: Unknown.
Property Name Property Implementation For x86 processors: Characteristics[0]: 3 (32-bit Capable) For x64 processors: Characteristics Characteristics[0]: 3 (32-bit Capable) Characteristics[1]: 2 (64-bit Capable) HP_ProcessorCore FALSE Bootstrap TRUE SMX_ProcessorCore 1-2-4 SMX_HardwareThread Class The SMX_HardwareThread class extends the CIM_HardwareThread class to model the hardware threads. The following table lists the properties implemented.
Property Name Property Implementation Stepping Processor: Core: Thread:) Where: is the processor brand string, ( is the cpu architecture type, is the processor family number, is the processor model number and is the processor stepping number, is the processor number, is the core number, and is the thread number. For example: Intel(R) Xeon(TM) CPU 3.06GHz (x86 Family 15 Model 2 Stepping 7) Manufacturer: Intel(R) Family: Xeon(TM) CPU 3.
Property Name Property Implementation Error, when OperationalStatus is 6 Stopped, when OperationalStatus is 10 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), when OperationalStatus[0]=2 (OK) HealthState 15 (Minor Failure), when OperationalStatus[0]=10 (Stopped) 20 (Major Failure), when OperationalStatus[0]=5 (Predictive Failure) 25 (Critical Failure), when OperationalStatus[0]=6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 12 (Not Applicabl
1-2-5 SMX_CacheMemory Class The SMX_CacheMemory class implements the HP_CacheMemory class, which extends CIM_Memory to model the processor caches. The following table lists the properties implemented.
Property Name Property Implementation 0 (Unknown) 2 (OK), when CPU is enabled and operational OperationalStatus 5 (Predictive Failure), when IML error info logged for this CPU 6 (Error), when CPU is disabled via POST error 10 (Stopped), when CPU is disabled via RBSU StatusDescriptions[0] text per OperationalStatus[0]: Unknown OK StatusDescriptions Stopped Error Predictive Failure 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), when OperationalStatus[0]=2 (OK) HealthState 15 (Minor Failure),
Property Name Property Implementation CIM_LogicalDevice SystemCreationClassName SMX_ComputerSystem SystemName Computer system name CreationClassName SMX_CacheMemory Proc
, Level Cache Where: is the processor number, is the cache level number, and is the cache type (Data, Instruction, or Unified) Proc , Core , Level Cache DeviceID Where: is the processor number, is the cache level number, and is the cache type (Data, Instruction, or Unified)
1-2-6 SMX_SystemProcessor Class The SMX_SystemProcessor class extends the CIM_SystemDevice class and associates the SMX_ComputerSystem instance and SMX_Processor instances. The following table lists the properties implemented.
1-2-8 SMX_ProcessorCoreComponent Class The SMX_ProcessorCoreComponent class extends the CIM_ConcreteComponent class and associates an SMX_Processor instance withSMXP_ProcessorCore instances. The following table lists the properties implemented.
1-2-10 SMX_AssociatedProcessorCacheMemory Class The SMX_AssociatedProcessorCacheMemory class extends the CIM_AssociatedCacheMemory class. The SMX_AssociatedProcessorCacheMemory class associates an SMX_Processor instance with an SMX_CacheMemory instance. The following table lists the properties implemented.
Property Name Property Implementation 0 (Unknown) 1 (Other) CacheType 2 (Instruction) 3 (Data) 4 (Unified) LineSize None 0 (Unknown) 1 (Other) 2 (Read) ReadPolicy 3 (Read-Ahead) 4 (Read and Read-Ahead) 5 (Determination Per I/O) 0 (Unknown) 1 (Other) 2 (Direct Mapped) 3 (2-way Set-Associative) Associativity 4 (4-way Set-Associative) 5 (Fully Associative) 6 (8-way Set-Associative) 7 (16-way Set-Associative) HP_AssociatedCacheMemory SMX_AssociatedProcessorCacheMemory HP Insight Management WBEM CPU Provid
Property Name Property Implementation Antecedent References SMX_CacheMemory Dependent References SMX_Processor 1-2-11 SMX_ProcessorCollection Class The SMX_ProcessorCollection class extends the HP_GroupSystemSpecificCollection class. The following table lists the properties implemented.
Property Name Property Implementation GroupOperationalStatus[0] contains the processors consolidated status. GroupOperationalStatus[0] will contain one of the following: 0 (Unknown) 1 (Other) 2 (OK) 3 (Degraded) GroupOperationalStatus 5 (Predictive Failure) 6 (Error) 10 (Stopped) The status values of the processors that make up the overall group operational status are contained in GroupOperationalStatus[1-n].
Property Name Property Implementation HP_ProcessorCollection SMX_ProcessorCollection 1-2-12 SMX_HostedProcessorCollection Class The SMX_HostedProcessorCollection class extends the HP_GroupHostedCollection class and associates the SMX_ComputerSystem instance with the SMX_ProcessorCollection instance. The following table lists the properties implemented.
Property Name Property Implementation SMX_MemberOfProcessorCollection Member References SMX_Processor Collection References SMX_ProcessorCollection 1-2-14 SMX_ProcessorChip Class The SMX_ProcessorChip class extends the CIM_Chip class to model the physical processor chip. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Processor in Caption For text representing the CPU location, refer to “Physical Location”.
Property Name Property Implementation StatusDescriptions[0] text per OperationalStatus[0]: Unknown.
Property Name Property Implementation (x86 Family 15 Model 2 Stepping 7) x86 Family 15 Model 2 Stepping 7 CreationClassName SMX_ProcessorChip Processor in ElementName For text representing the CPU location, refer to “Physical Location”.
Property Name RemovalConditions Property Implementation 3 (Removable When Off) CIM_Chip HP_ProcessorChip Stepping ProcessorChipRevision Where: is the processor stepping number SMX_ProcessorChip 1-2-15 SMX_RealizesProcessor Class The SMX_RealizesProcessor class extends the CIM_Realizes class and associates SMX_Processor instances with SMX_ProcessorChip instances. The following table lists the properties implemented.
Property Name Property Implementation CIM_Component CIM_Container HP_SystemPhysicalProcessor SMX_SystemPhysicalProcessor GroupComponent References SMX_ComputerSystemChassis PartComponent References SMX_ProcessorChip 1-2-17 SMX_ProcessorLocation Class The SMX_ProcessorLocation class implements the HP_Location class which extends the class CIM_Location. For ProLiant systems, processor location is denoted by the use of a slot number designator and a socket number designator.
Property Name Property Implementation ( Family Model Stepping ) Description Where : is the processor brand string, is the CPU architecture type, is the processor family number, is the processor model number and is the processor stepping number. For example: Intel(R) Xeon(TM) CPU 3.06GHz (x86 Family 15 Model 2 Stepping 7) Manufacturer: Intel(R) Family: Xeon(TM) CPU 3.
Property Name Property Implementation HP_Location ElementLocationTag For text representing the CPU location, refer to “Physical Location”.
Property Name Property Implementation HP_ProcessorLocation SMX_ProcessorLocation 1-2-18 SMX_ProcessorElementLocation Class The SMX_ProcessorElementLocation class extends the HP_ElementLocation class and associates SMX_ProcessorChip instances with SMX_ProcessorLocation instances. The following table lists the properties implemented.
ProcessorBoard= System Mainboard(referring to motherboard) CPUSocket= on ProcessorBoard= 1-4 Blade= Cell= _ _ _ _ Provider Indications Indications Generated by the Provider The SMX CPU Provider generates WBEM indications described in the following sections. Note These Indications only apply to Proliant Servers.
Property Name Property Implementation Provider Version in the format VV.UU.FF. ProviderVersion NetworkAddresses For example: 01.05.00 Contains a list of all the IP addresses of the computer system generating the indication. On ESX, 39 (VM). OSType On Linux, 36 (Linux). OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation CIM_AlertIndication Description CPU Failed Power on Self Test (POST) AlertType 5 (Device Alert) EventID 1 EventCategory 2 (Processor) ProviderName HP Processor RecommendedActions Replace the failed processor HP_AlertIndication Summary CPU Failed Power on Self Test (POST) ProbableCause 1 (Other) 1-4-3 HP_DeviceIndication: Processor Disabled by BIOS or EFI Property Name Property Implementation CIM_Indication PerceivedSeverity 4 (Minor) CIM_AlertIndic
Property Name Property Implementation ProviderName HP Processor RecommendedActions Enable processor via BIOS or EFI HP_AlertIndication Summary CPU has been disabled by BIOS or EFI ProbableCause 1 (Other) HP Insight Management WBEM CPU Provider Overview 35
1-4-4 HP_DeviceIndication: Processor Predicted to fail Property Name Property Implementation CIM_Indication PerceivedSeverity 4 (Minor) CIM_AlertIndication Description CPU Predictive Failure Notification AlertType 5 (Device Alert) EventID 3 EventCategory 2 (Processor) ProviderName HP Processor RecommendedActions Replace the failing processor.
1 HP Insight Manager WBEM Ethernet Description The HP Insight Management Web-Based Enterprise Management (WBEM) Ethernet Port provider implements and extends Common Information Model (CIM) classes described in this document to model the ethernet port. These classes reside in the local host OS CIM Object Manager (CIM OM) on each individual monitored system and describe the ethernet ports, associated controllers, and logical ethernet interfaces that are available in the system.
Release History 1-1 Initial release with HP Insight Management WBEM Providers for Linux v2.0. Setting Up the Provider Installing the Provider There are no special installation instructions for this provider. It is installed by default as part of the HP Insight Management WBEM providers. Configuring the Provider This provider does not accept specific configuration adjustments beyond standard HP Insight Management WBEM support.
• SMX_EthernetRemoteServiceAccessPoint • SMX_EthernetRemoteAccessAvailableToIPEndpoint • SMX_EthernetRemoteServiceHostedAccessPoint • SMX_EthernetStatistics • SMX_EthernetPortStatisticalData • SMX_EthernetPortControllerSoftwareIdentity • SMX_EthernetPortControllerFirmwareIdentity • SMX_EthernetElementSoftwareIdentity • SMX_EthernetElementFirmwareIdentity • SMX_EthernetCollection • SMX_EthernetMemberOfCollection • SMX_EthernetGroupHostedCollection • SMX_EthernetTeam, • SMX_Ethermet
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Text describing this port as advertised from PCI configuration/header information. Caption For example: Broadcom Corporation NetXtreme BCM5753M Gigabit Ethernet PCI Express (rev 21). A description of the instance with unique port number for each port on a particular controller. Description For example: Ethernet port on ethernet controller .
Property Name Property Implementation OK Degraded Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice CreationClassName SMX_EthernetPort DeviceID HPQ:SMX_EthernetPort: SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem Current bandwidth in bits per second if port has link (value is 0, MaxSpeed otherwise).
Property Name Property Implementation The logical MAC address of the Ethernet Port, typically for the format FFFFFFFFFFFF Permanent Address Where: each is a text representation of a hexadecimal digit 0x0 - 0xF. Unique number assigned to each Ethernet Port on a given ethernet PortNumber controller in the form of . These numbers are not unique across multiple controllers that exist on the same system. Current bandwidth in bits per second if port has link (value is 0, Speed otherwise).
Property Name Property Implementation 102 (1000Base-SX) 103 (1000Base-LX) 104 (1000Base-CX) 105 (10GBase-SR) 106 (10GBase-SW) 107 (10GBbase-LX4) 108 (10GBase-LR) 109 (10GBase-LW) 110 (10GBase-ER) 111 (10GBase-EW) Array of 16 bit unsiged integers advertising the capabilities of the EthernetPort: 0 (Unknown) Capabilities[] 1 (Other) 2 (AlertOnLan) 3 (WakeOnLan) Capability Descriptions[0] per Capabilities[0]. Text descriptions for the Capabilities array above.
Property Name NetworkAddresses[] Property Implementation Array of MAC addresses affiliated with port. Formatted like 001122334455 with no delimiting. HP_EthernetPort Non-Zero Virtual Port Number for FlexNICs that are partitioned. VirtualPortNumber 1-2-2 Value is 0 for non-Flex NICs and FlexNICs that are not partitioned.
Property Name Property Implementation For example: LAN Endpoint (instanceNum) for: 82546GB Gigabit Ethernet Controller port CIM_ManagedSystemElement 5 (OK), normal operation HealthState 20 (MajorFailure) Name Opaque key, of the format HPQ:SMX_EthernetLANEndpoint:instanceNumber 0 (Unknown) 2 (OK) OperationalStatus 3 (Degraded - indicating that there is no link for this port) 6 (Error - indicating a link that was active is now lost) StatusDescriptions[0] per OperationalStatus[0]: Unknown S
Property Name SystemCreationClassName Property Implementation SMX_ComputerSystem CIM_ProtocolEndpoint Text representing of what the operating system labels this endpoint. Description For example: eth3 LAN Endpoint information for OS Exposed Ethernet Port information.
Property Name Property Implementation CIM_HostedAccessPoint HP_EthernetLANHostedAccessPoint Antecedent Reference to SMX_ComputerSystem. Dependent Reference to SMX_EthernetLANEndpoint. 1-2-5 SMX_EthernetPortToLANEndpoint Class The SMX_EthernetPortToLANEndpoint class implements the HP_EthernetPortToLANEndpoint class and associates the Ethernet Port instance to its Ethernet LAN Endpoint instance. The following table lists the properties implemented.
Property Name Property Implementation For example: Ethernet Controller controller_id A description of the class. Description For example: Ethernet Controller A description of the class. ElementName For example: Ethernet Controller CIM_ManagedSystemElement HealthState 5 (OK - normal operation) A description of the class.
Property Name Property Implementation CIM_Controller CIM_PortController 2 (Ethernet) ControllerType Hardware revision number of the controller or None if unknown, ControllerVersion and None for non-numeric revisions ExtendedControllerVersion 1-2-7 Hardware revision number of the controller for non-numeric revisions SMX_EthernetPortControllerPCIDevice Class The SMX_EthernetPortControllerPCIDevice class implements the HP_EthernetPortControllerPCIDevice class and associates an Ethernet Port Controller
Property Name Property Implementation CIM_ControlledBy HP_EthernetPortControllerEthernetPort Antecedent Reference to SMX_EthernetPortController. Dependent Reference to SMX_EthernetPort 1-2-9 SMX_EthernetPortControllerPhysicalPackage Class The SMX_EthernetPortControllerPhysicalPackage class implements the HP_EthernetPortControllerPhysicalPackage class and describes an Ethernet Port Controller Physical Package.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Product name.
Property Name Property Implementation Text representing vendor information from PCI configuration space. Manufacturer For example: HP, Intel, Broadcom Tag Opaque key HPQ:SMX_EthernetPortControllerPhysicalPackage: controller_id Version Hardware version of the Package or N/A CIM_PhysicalPackage If PackageType is 1 (Other), then this text will further describe the package.
Property Name Property Implementation HP_EthernetControllerPhysicalPackageEthernetController Antecedent SMX_EthernetPortControllerPhysicalPackage. Reference to SMX_EthernetPortController. Dependent 1-2-11 Reference to SMX_EthernetControllerLocation Class The SMX_EthernetControllerLocation class implements the HP_EthernetControllerLocation class. It describes the location information of the Ethernet Controller Physical Package or card. The following table lists the properties implemented.
Property Name Property Implementation HP_Location 23 (PCI Adapter Slot) ElementLocationTagDesc 18 (Embedded Port) ElementLocationTag Refer to “Physical Location” for more information. Array of numerical enumerators describing values at comparable index in the LocationInformation array index 1, 2, 3, or 4.
SMX_EthernetControllerPhysicalPackageEthernetControlle rLocation Class 1-2-12 The SMX_EthernetControllerPhysicalPackageEthernetControllerLocation class implements the HP_EthernetControllerPhysicalPackageEthernetControllerLocation class and associates SMX_EthernetControllerPhysicalPackageto its logical SMX_EthernetControllerLocation. The following table lists the properties implemented.
Property Name Value Operating System ethernet device name. Description For example: eth1 For ESXi, management network logical interface name. For example: vmk0-ipv4-0 CIM_ManagedSystemElement HealthState Same as associated LAN Endpoint.
Property Name Value 3 (Degraded) 6 (Error) CIM_IPProtocolEndpoint How the Address was assigned to this IP Protocol Endpoint. 0 (Unknown) AddressOrigin 3 (Static) 4 (DHCP) IPv4Address Only initialized if IP interface advertises a valid IPv4 Address. IPv6Address Only initialized if IP interface advertises a valid IPv6 Address. If ProtocolIFType is 4097 or 4098, then this property will be implemented. IPv6AddressType 3 (Loopback) 5 (Link Local Unicast) 7 (Embedded IPv4 Address) Unsigned integer.
Property Name Value Opaque Key. Unique scoped instance information HPQ:SMX_IPProtocolEndpoint: concatenated with the class instance id number. 1 (Other) 4096 (IPv4) ProtocolIFType 4097 (IPv6) 4098 (IPv4/IPv6) SubnetMask Text representing the mask of the IPv4 address, if defined; otherwise, 0.0.0.
Property Name Reference to SMX_IPProtocolEndpoint. Dependent 1-2-15 Property Implementation SMX_EthIPHostedAccessPoint SMX_EthIPHostedAccessPoint implements the class HP_EthIPHostedAccessPoint and associates IP Protocol Endpoints to the Computer System.
Property Name Property Implementation CIM_LogicalElement CIM_EnabledLogicalElement CIM_ServiceAccessPoint CreationClassName SMX_RemoteServiceAccessPoint A unique description of the gateway. Name For example: RemoteServiceAccessPoint: Gateway for interface_name SystemCreationClassName SMX_ComputerSystem SystemName SMX_ComputerSystem.
NOTE: Currently not implemented on on VMware ESXi platform. The following table lists the properties implemented. Property Name Property Implementation CIM_Dependency CIM_RemoteAccessAvailableToElement Boolean true if only 1 default and only 1 gateway is present. In some systems, there may be order of access constraints if multiple gateways are present.
Property Name Property Implementation HP_EthernetLANHostedAccessPoint Antecedent Reference to SMX_ComputerSystem Dependent Reference to SMX_EthernetRemoteServiceAccessPoint 1-2-19 SMX_EthernetStatistics SMX_EthernetStatistics implements the class HP_EthernetStatistics. The following table lists the property implementation for SMX_EthernetStatistics. Property Name Property Implementation CIM_ManagedElement Caption For Ethernet Ports, same as associated EthernetPort.Caption.
Property Name Property Implementation BytesTransmitted Total number of bytes transmitted PacketsReceived Total number of packets received CIM_EthernetPortStatistics AlignmentErrors See CIM_EthernetPortStatistics mof. DeferredTransmissions See CIM_EthernetPortStatistics mof. ExcessiveCollisions See CIM_EthernetPortStatistics mof. FCSErrors See CIM_EthernetPortStatistics mof. InternalMACReceiveErrors See CIM_EthernetPortStatistics mof.
Property Name Property Implementation HP_EthernetPortStatisticalData 1-2-21 SMX_EthernetPortControllerSoftwareIdentity SMX_EthernetPortControllerSoftwareIdentity implements the class CIM_SoftwareIdentity. It represents the adapter driver software of the associated Ethernet Port. Property Name Property Implementation CIM_ManagedElement Caption Ethernet Port Controller Driver Description Device Driver Where: is the product name of the Ethernet Adapter.
1-2-22 SMX_EthernetPortControllerFirmwareIdentity SMX_EthernetPortControllerFirmwareIdentity implements the class CIM_SoftwareIdentity. It represents the adapter firmware of the associated Ethernet Port. Property Name Property Implementation CIM_ManagedElement Caption Ethernet Port Controller Firmware Description Ethernet Port Controler Firmware details for Where: is the Model name of the Ethernet Adapter.
Property Name Property Implementation [0]: 'HPQ:' [1]: 'NIC' TargetTypes An array of strings that describes the compatible installer(s). Currently a blank array in SMX : [''] Manufacturer Manufacturer VersionString Firmware Version 1-2-23 SMX_EthernetElementSoftwareIdentity SMX_EthernetElementSoftwareIdentity implements the class CIM_ElementSoftwareIdentity. It represents the association between SMX_EthernetPortController and SMX_EthernetPortControllerSoftwareIdentity.
Property Name Property Implementation CIM_ Dependency Antecedent ref:SMX_EthernetPortControllerFirmwareIdentity Dependent ref:SMX_EthernetPortController CIM_ElementSoftwareIdentity ElementSoftwareStatus 1-2-25 ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) SMX_EthernetCollection SMX_EthernetCollection implements the class HP_EthernetCollection. It represents the collection of all Ethernet Ports.
Property Name Property Implementation 3 (Degraded) 6 (Error) GroupStatusDescriptions GroupStatusDescriptions[0] per GroupOperationalStatus[0]: Unknown OK Degraded Error HP_EthernetCollection 1-2-26 SMX_EthernetMemberOfCollection SMX_EthernetMemberOfCollection associates Ethernet Ports to the Ethernet Collection.
Property Name Property Implementation HP_EthernetMemberOfCollection 1-2-27 SMX_EthernetGroupHostedCollection SMX_EthernetGroupHostedCollection associates the Ethernet Collection to the Computer System. Property Name Property Implementation CIM_Dependency Antecedent ref:SMX_ComputerSystem Dependent ref:SMX_EthernetCollection CIM_HostedDependency CIM_HostedCollection HP_EthernetGroupHostedCollection 1-2-28 SMX_EthernetTeam SMX_EthernetTeam models Ethernet Redundancy Sets (Ethernet Teams).
Property Name Property Implementation Local Area Connection #10 ElementName Same as caption. CIM_Collection CIM_SystemSpecificCollection Key:InstanceId System GUID for the team. CIM_RedundancySet LoadBalanceAlgorithm 0 (None) 1 (Other) 3 (Round Robin) MaxNumberSupported Number of ports configured in team. MinNumberNeeded 1 OtherLoadBalanceAlgorithm When LoadBalanceAlgorithm is 1 (Other), OtherLoadBalanceAlgorithm is set to configured Load Balance Algorithm.
Property Name GroupOperationalStatus Property Implementation 2 (OK) 3 (Degraded) 6 (Error) HP_EthernetTeam ActiveMaximumTransmissionUnit Current maximum transmission unit in bytes. Speed The current bandwidth of the team in bits per second. Capabilities of an Ethernet Team. Refer to Windows Ethernet Teaming mof, HP_WinEthRedundancySet.mof TeamCapabilities[] For example: Fast Path Failover Current operating mode of the Ethernet Team. TeamCurrentOperatingMode For example: 802.
Property Name Property Implementation CIM_MemberOfCollection Key:Collection ref:HP_EthernetTeam Key:Member ref:HP_EthernetPort HP_EthernetTeamMember MemberOperationalStatus 2 (OK) 3 (Degraded) 6 (Error) MemberStatusDescriptions Refer to HP Ethernet Teaming Profile.
Property Name Property Implementation Key:OwnedElement ref:HP_EthernetTeam Key:OwningElement ref:HP_ComputerSystem HP_HostedEthernetTeam 1-2-31 SMX_EthernetTeamToLANEndpoint SMX_EthernetTeamToLANEndpoint associates the Ethernet Teams to the Ethernet LAN Endpoints. NOTE: Currently not implemented on on VMware ESXi platform.
Property Name Property Implementation ElementName HP Ethernet Event Provider configurable settings InstanceId 0 HP_EthEventSettings SMX_EthEventSettings ActiveAdapterCountChanged If enabled, an event is generated when a change is detected in number of active adapter count of a team. Default, disabled. FloodThreshold Time, in seconds, used for indication flood control, default 10 seconds InterfaceAvailable If enabled, an event is generated when a network interface becomes available.
Property Name Property Implementation MonitorRedundancySets If enabled, events related to SMX_EthernetTeam are generated. Default, true. PolInterval The longest interval between network status polls, in seconds. Value 0 disables polling and is not recommended. Using very low values can increase CPU utilization. Default 200.
Property Name Property Implementation the indication On ESX, 39 (VM) OSType On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation transitioned from OK to Error. AlertingManagedElement WBEM Path of the SMX_EthernetPort instance AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) EventID 2 ProviderName HP Ethernet RecommendedActions View the Ethernet Port status in HP Systems Insight Manager (SIM). View the System Event Log for additional information. HP_AlertIndication Summary The Network interface has lost connectivity.
Property Name PerceivedSeverity Property Implementation 2 (Information) CIM_Alertindication Description If the Network Interface is an Ethernet Port, the Ethernet Port has transitioned from Error to OK.
HP_AlertIndication: Group System Specific Consolidated Status Policy Change 1-3-3 Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Informational) CIM_Alertindication Description HP_GroupSystemSpecificConsolidated operational status policy has been modified to monitor operational status from different set of managed elements.
Property Name Property Implementation HP_GroupSystemSpecificCollection. NOTE: Indications 1-3-4 thru 1-3-14 are currently not implemented on on VMware ESXi platform. 1-3-4 HP_AlertIndication:Ethernet Team Redundancy Lost Property Name Property Implementation CIM_Indication PerceivedSeverity 6 (Critical) CIM_Alertindication Description An Ethernet team's redundancy status changed to Redundancy Lost. All members of an Ethernet team, except one, are failed.
Property Name Property Implementation EventSubCategory 12 (Ethernet team) ProbableCause 88 (Loss of Redundancy) ProbableCauseDescription Ethernet Team Redundancy Lost 1-3-5 HP_AlertIndication: Ethernet Team Redundancy Increased Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_Alertindication Description An Ethernet team's redundancy has increased. A team member recovered from a failed or degraded state.
Property Name Property Implementation EventSubCategory 12 (Ethernet team)) ProbableCause 1 (Other) ProbableCauseDescription Ethernet Team Redundancy Increased 1-3-6 HP_AlertIndication: Ethernet Team Redundancy Decreased Property Name Property Implementation CIM_Indication PerceivedSeverity 3 (Warning) CIM_Alertindication Description An Ethernet team's redundancy has decreased. A team member has changed to failed or degraded state.
Property Name Property Implementation EventCategory 9 (Network Device) EventSubCategory 12 (Ethernet team) ProbableCause 88 (Loss of Redundancy) ProbableCauseDescription Ethernet Team Redundancy Decreased 1-3-7 HP_AlertIndication: Ethernet Team Redundancy Restored Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_Alertindication Description An Ethernet team's redundancy status changed to Fully Redundant.
Property Name Property Implementation EventCategory 9 (Network Device) EventSubCategory 12 (Ethernet team) ProbableCause 1 (Other) ProbableCauseDescription Ethernet Team Redundancy Status Changed to Fully Redundant 1-3-8 HP_AlertIndication: Ethernet Team Member Status Change Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_Alertindication Description An Ethernet team member's status has changed.
Property Name Property Implementation Summary Ethernet team member reported status change EventCategory 9 (Network Device) EventSubCategory 12 (Ethernet team) ProbableCause 1 (Other) ProbableCauseDescription Ethernet Team Member Status Change 1-3-9 HP_AlertIndication: Ethernet Team Member Role Change Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_Alertindication Description An Ethernet Team member's role has changed.
Property Name Property Implementation HP_AlertIndication Summary Ethernet Team Member Reported Role Change.
Property Name RecommendedActions Property Implementation Check the Ethernet Team and Ethernet Team Member status. View the System Event Log for additional information. HP_AlertIndication Summary Ethernet Team Member Dropped from Team.
Property Name Property Implementation ProviderName HP Ethernet RecommendedActions No action is recommended.
Property Name Property Implementation EventID 12 ProviderName HP Ethernet RecommendedActions Ensure the network interface was made unavailable intentionally.
Property Name Property Implementation AlertType 2 (Communications Alert) EventID 11 ProviderName HP Ethernet RecommendedActions No action is recommended.
Property Name Property Implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) EventID 13 ProviderName HP Ethernet RecommendedActions Check the Ethernet Team and Ethernet Team Member status. View the System Event Log for additional information. HP_AlertIndication Summary Ethernet team reported change in number of active members.
System Board) Controller= System Mainboard (referring to System Board/motherboard) Chassis= Mezzanine= (I/O Mezzanine slot num) HP Insight Manager WBEM Ethernet 56
1 HP Insight Manager WBEM Fibre Channel Host Bus Adapter Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Fibre Channel Host Bus Adapter Profile describes the behavior of Fibre Channel host adapters supporting the SCSI (Fibre Channel Protocol) command set. A Fibre Channel (FC) adapter used in a host system is called a Host Bus Adapter (HBA). An HBA is a physical device that contains one or more Fibre Channel ports. A single system can contain one or more HBAs.
1-1 Setting Up the Provider Installing the Provider There are no special installation instructions for this provider. It is installed by default as part of the HP Insight Management WBEM providers. Configuring the Provider This provider does not accept specific configuration adjustments beyond standard HP Insight Management WBEM support. 1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
• SMX_FCHBAFCPortFCPortStatistics • SMX_FCHBAFCPortLogicalPortGroup • SMX_FCHBAPortControllerFCPort • SMX_FCHBAPhysicalPackagePortController • SMX_FCHBASoftwareIdentityDrvPortController • SMX_FCHBAPortControllerFirmwareIdentityFW • SMX_FCHBAPortControllerFirmwareIdentityBIOS • SMX_FCHBAProductPhysicalComponent • SMX_FCHBASystemPackaging • SMX_FCHBAGroupHostedCollection • SMX_FCHBAFCPortGroupSystemSpecific • SMX_FCHBALocation • SMX_FCHBAPhysicalElementLocation The tables in the foll
Property Name ElementName Property Implementation Fibre Channel System CIM_ManagedSystemElement Name OperationalStatus[0] GUID 0 (Unknown) 2 (OK) 6 (Error) 10 (Stopped) StatusDescriptions[0] Unknown OK Stopped Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_Systems CreationClassName SMX_FCHBAComputerSystem NameFormat Other CIM_ComputerSystem HP Insight Manager WBEM Fibre Channel Host Bus Ada
Property Name Property Implementation Dedicated 0 IdentifyingDescriptions[0] HPQ:GUID OtherIdentifyingInfo[0] GUID 1-2-2 SMX_FCHBAFCPort Class The SMX_FCHBAFCPort class implements the HPFCHBA_FCPort class is used to represent a FC port device. The following table lists the properties implemented.
Property Name Value Unknown OK-Online Stopped Offline StatusDescriptions[0] Stopped Bypassed Stopped Diagnostics Stopped Link down Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_FCHBAFCPort DeviceID Opaque value. SystemName Opaque value.
Property Name Value 10000000000 Unknown Other Not present Fabric Public Loop OtherPortType FL Port Fabric Port Fabric expansion port Generic Fabric Port Private Loop Point to Point PortType 1 (Other) Typically one of the following (in Bits per Second): 0 Speed 1000000000 2000000000 10000000000 UsageRestriction 4 (not restricted) CIM_NetworkPort LinkTechnology 4 (FC) HP Insight Manager WBEM Fibre Channel Host Bus Adapter Provider 7
Property Name Value PermanentAddress Port WWN PortNumber Port number. SupportedMaximumTransmissionUnit Port maximum frame size. 1-2-3 SMX_FCHBAPortController Class The SMX_FCHBAPortController class represents a logical device corresponding to a hardware network port controller. The following table lists the properties implemented.
Property Name Value Where: is the port controller instance number for the same adapter. SystemCreationClassName SMX_FCHBAComputerSystem SystemName Opaque CIM_Controller CIM_PortController ControllerType 1-2-4 4 (FC) SMX_FCHBAFCPortStatistics Class The SMX_FCHBAFCPortStatistics class represents statistics for a FC port. . The following table lists the properties implemented and the HBAAPI_PORTSTATISTICS prefix refers to the HBA API HBA_PORTSTATISTICS structure.
Property Name Value PacketsTransmitted HBAAPI_PORTSTATISTICS.TxFrames PacketsReceived HBAAPI_PORTSTATISTICS.RxFrames CIM_FCPortStatistics CRCErrors HBAAPI_PORTSTATISTICS.InvalidCRCCount DumpedFrames HBAAPI_PORTSTATISTICS.DumpedFrames ErrorFrames HBAAPI_PORTSTATISTICS.ErrorFrames InvalidTransmissionWords HBAAPI_PORTSTATISTICS.InvalidTxWordCount LinkFailures HBAAPI_PORTSTATISTICS.LinkFailureCount LIPCount HBAAPI_PORTSTATISTICS.LIPCount LossOfSignalCounter HBAAPI_PORTSTATISTICS.
The following table lists the properties implemented. Property Name Value CIM_ManagedElement Description Grouping of all FC Ports for this HBA Caption Logical Port Group ElementName Logical Port Group CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque CIM_LogicalPortGroup Name NodeWWN NameFormat WWN 1-2-6 SMX_FCHBAPhysicalPackage Class The SMX_FCHBAPhysicalPackage class represents the physical elements of the associated FC port controller.
Property Name Value 1 (Other) 2 (OK) OperationalStatus[] 3 (Degraded) 6 (Error) CIM_PhysicalElement CreationClassName SMX_FCHBAPhysicalPackage Manufacturer Manufacturer Model Model Location; PCI Slot OtherIdentifyingInfo Where: is the PCI slot number OR PCI Mezzanine= where is the Mexannine slot number.
Property Name Value CIM_ManagedElement ElementName Product Name CIM_Product IdentifyingNumber HBAAPI_ADAPTERATTRIBUTES.VendorSpecificID NodeWWN: Name Where: is the port controller instance number for the same adapter Vendor Manufacturer Version F/W Version of HBA or N/A when not available 1-2-8 SMX_FCHBASoftwareIdentityDrv Class The SMX_FCHBASoftwareIdentityDrv class represents adapter software associated with the FC port controller.
Property Name Value CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions FCHBA Driver Classifications 2 (Driver) HPQ:NodeWWN: InstanceID Where: is the port controller instance number for the same adapter Manufacturer Manufacturer VersionString File version of the Driver. 1-2-9 SMX_FCHBAFirmwareIdentityFW Class The SMX_FCHBAFirmwareIdentityFW class represents adapter firmware associated with the FC port controller.
Property Name Value CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions FCHBA Firmware Classifications 10 (firmware) HPQ:NodeWWN: InstanceID Where: is the port controller instance number for the same adapter Manufacturer Manufacturer SerialNumber Serial number VersionString Firmware version 1-2-10 SMX_FCHBAFirmwareIdentityBIOS Class The SMX_FCHBAFirmwareIdentityBIOS class represents adapter BIOS associated with the FC port controller.
Property Name Value NodeWWN Name CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions FCHBA Option ROM Classifications 11 (bios/fc) HPQ:NodeWWN: InstanceID Where: is the port controller instance number for the same adapter Manufacturer Manufacturer VersionString BIOS Version as reported by HBA TargetTypes HBA BIOS UNKNOWN SerialNumber Serial Number MajorVersion BIOS MajorVersion as reported by HBA MinorVersion BIOS MinorVersion as reported by HBA
Property Name Value CIM_ManagedElement Caption FCHBA Consolidated Status Description Consolidated status for HP FC HBAs ElementName FCHBA Consolidated Status CIM_Collection CIM_SystemSpecificCollection Opaque InstanceID HP_GroupSystemSpecificCollection 0 (Unknown) 1 (Other) 2 (OK) GroupOperationalStatus[0] 3 (Degraded) 6 (Error) 10 (Stopped) Unknown Other OK GroupStatusDescriptions[0] Degraded Error Stopped 1-2-12 SMX_FCHBAComputerSystemFCPort Class The SMX_FCHBAComputerSystemFCPort class is us
The following table lists the properties implemented. Property Name Value CIM_Component CIM_SystemDevice SMX_FCHBAComputerSystemFCPort GroupComponent Refer to SMX_FCHBAComputerSystem class properties. PartComponent Refer to SMX_FCHBAFCPort class properties. 1-2-13 SMX_FCHBAComputerSystemPortController Class The SMX_FCHBAComputerSystemPortController class is used to represent an association between SMX_ComputerSystem and SMX_FCHBAPortController. The following table lists the properties implemented.
CIM_ConcreteIdentity SMX_FCHBAPortControllerPCIDevice SystemElement Refer to SMX_PCIDevice class properties. SameElement Refer to SMX_FCHBAPortController class properties. 1-2-15 SMX_FCHBAComputerSystemLogicalPortGroup Class The SMX_FCHBAComputerSystemLogicalPortGroup class is used to represent an association between SMX_ComputerSystem and SMX_FCHBALogicalPortGroup. The following table lists the properties implemented.
Property Name Value SMX_FCHBAComputerSystemSoftwareIdentityDrv InstalledSoftware Refer to SMX_FCHBASoftwareIdentityDrv class properties. System Refer to SMX_FCHBAComputerSystem class properties. 1-2-17 SMX_FCHBAFCPortFCPortStatistics Class The SMX_FCHBAFCPortFCPortStatistics class is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBAFCPortStatistics. The following table lists the properties implemented.
1-2-19 SMX_FCHBAPortControllerFCPort Class The SMX_FCHBAPortControllerFCPort is used to represent an association between SMX_FCHBAPortController and SMX_FCHBAFCPort. The following table lists the properties implemented. Property Name Value CIM_Dependency CIM_ControlledBy SMX_FCHBAPortControllerFCPort Antecedent Refer to SMX_FCHBAPortController class properties. Dependent Refer to SMX_FCHBAFCPort class properties.
The following table lists the properties implemented. Property Name Value CIM_Dependency CIM_ElementSoftwareIdentity SMX_FCHBASoftwareIdentityDrvPortController Antecedent Refer to SMX_FCHBASoftwareIdentityDrv class properties. Dependent Refer to SMX_FCHBAPortController class properties. 1-2-22 SMX_FCHBAPortControllerFirmwareIdentityFW Class The SMX_FCHBAPortControllerFirmwareIdentityFW class is used to represent an association between SMX_FCHBAPortController and SMX_FCHBAFirmwareIdentityFW.
CIM_Dependency CIM_ElementSoftwareIdentity SMX_FCHBAPortControllerFirmwareIdentityBIOS Antecedent Refer to SMX_FCHBAFirmwareIdentityBIOS class properties. Dependent Refer to SMX_FCHBAPortController class properties. 1-2-24 SMX_FCHBAProductPhysicalComponent Class The SMX_FCHBAProductPhysicalComponent class is used to represent an association between SMX_FCHBAProduct and SMX_FCHBAPhysicalPackage. The following table lists the properties implemented.
SMX_FCHBASystemPackaging Antecedent Refer to SMX_FCHBAPhysicalPackage class properties. Dependent Refer to SMX_FCHBAComputerSystem class properties. 1-2-26 SMX_FCHBAGroupHostedCollection Class The SMX_FCHBAGroupHostedCollection class is used to represent an association between SMX_ComputerSystem and SMX_FCHBAGroupSystemSpecificCollection. The following table lists the properties implemented.
SMX_FCHBAFCPortGroupSystemSpecific Collection Refer to SMX_FCHBAGroupSystemSpecificCollection class properties. Member Refer to SMX_FCHBAFCPort class properties. 1-2-28 SMX_FCHBALocation Class The SMX_FCHBALocation class is used to specify the location of the HBA, PCI Slot number. The following table lists the properties implemented.
Property Name Value CIM_ElementLocation SMX_FCHBAPhysicalElementLocation Element Refer to SMX_FCHBAPhysicalPackage class properties. PhysicalLocation Refer to SMX_FCHBALocation class properties. 1-2-30 SMX_FCHBASCSIProtocolController SMX_FCHBASCSIProtocolController represents a protocol controller that manages a SCSI interface. This class is used for backward compatibility with SMI-S 1.0.
Property Name RequestedState Value 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_FCHBASCSIProtocolController DeviceID PortWWN SystemName Opaque value SystemCreationClassName SMX_FCHBAComputerSystem CIM_ProtocolController MaxUnitsControlled 255 CIM_SCSIProtocolController 1-2-31 SMX_FCHBASCSIProtocolEndpoint SMX_FCHBASCSIProtocolEndpoint represents a SCSI protocol controller running through a part.
Property Name Value 12 (Not Applicable) RequestedState CIM_ServiceAccessPoint CreationClassName SMX_FCHBASCSIProtocolEndpoint SystemName Opaque value SystemCreationClassName SMX_FCHBAComputerSystem CIM_ProtocolEndpoint 57 (HIPPI Interface) ProtocolIFType CIM_SCSIProtocolController ConnectionType 2 (fibre channel) Role 2 (initiator) 1-2-32 SMX_FCHBAComputerSystemSCSIProtocolController SMX_FCHBAComputerSystemSCSIProtocolController is used to represent an association between SMX_FCHBAComputer
1-2-33 SMX_FCHBAFCPortSCSIProtocolEndpoint SMX_FCHBAFCPortSCSIProtocolEndpoint is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBASCSIProtocolEndpoint.
1-2-35 SMX_FCHBASystemServiceAccessPoint SMX_FCHBASystremServiceAccessPoint is used to represent an association between SMX_FCHBAComputerSystem and SMX_FCHBASCSIProtocolEndpoint.
user can uniquely locate the device. Most of these strings will be represented in customer documentation, silkscreen labels, or hood tags. The following table lists the properties implemented. Any combination of the following applicable descriptors could be used to better define the device location.
1 HP Insight Manager WBEM Host File System Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Host Filesystem provider and extends CIM classes described in this document to model the filesystems hosted by a managed node. These classes provide computational information and capabilities that serve as an aggregation point to associate one or more elements that make up hosted filesystems and logical disks.
Provider 1-2 Insight Management WBEM support. Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace. Schema Supported by the Provider This provider supports the following classes: • SMX_LocalFileSystem • SMX_HostedLocalFileSystem • SMX_LocalLogicalDisk • SMX_LocalFSResidesOnExtent The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation CIM_EnabledLogicalElement CIM_FileSystem CSName SMX_ComputerSystem.Name CSCreationClassName SMX_ComputerSystem.CreationClassName CreationClassName SMX_LocalFileSystem Name Same as Root property. OS path name to filesystem root location. Root For example: /home/users AvailableSpace Total amount of free space for the filesystem in bytes. Unknown = 0. BlockSize Read/write data block size in bytes. FileSystemSize Total size of the filesystem in bytes.
Property Name Property Implementation CIM_HostedFileSystem SMX_HostedLocalFileSystem PartComponent References SMX_LocalFileSystem GroupComponent References SMX_ComputerSystem 1-2-3 SMX_LocalLogicalDisk Class The SMX_LocalLogicalDisk class implements the CIM_LogicalDisk class and presents a contiguous range of logical blocks hosted locally on the managed node. These LogicalDisks are identifiable by applications through the Name field, which contains the access path to the logical disk.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement CIM_LogicalDevice SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName CreationClassName SMX_LocalLogicalDisk Path to logical disk. DeviceID For example: /dev/cdrom1 CIM_StorageExtent BlockSize Read/write data block size in bytes.
Property Name Property Implementation CIM_LogicalDisk 1 (Other) NameFormat 12 (OS Device Name) 1 (Other) NameNamespace 8 (OS Device Namespace) SMX_LogicalDisk 1-2-4 SMX_LocalFSResidesOnExtent Class The SMX_LocalFSResidesOnExtent class implements the CIM_ResidesOnExtent class and associates the SMX_LocalFileSystem and SMX_LocalLogicalDisk instances. The following table lists the properties implemented.
1 HP Insight Management WBEM IML Record Log Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Integrated Management Log (IML) provider implements the server management record log. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Record Log Profile (P00109) HP WBEM TC 1.1.
• SMX_IMLRecordLog • SMX_IMLLogEntry • SMX_IMLLogManagesRecord • SMX_IMLUseOfLog The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name Property Implementation OperationalStatus[0] indicates the highest severity of IML log entries and will contain one of the following: OperationalStatus 2 (OK), only informational or repaired events exist in the IML log 3 (Degraded), at least one degraded event exists in the IML log 6 (Error), at least one critical event exists in the IML log StatusDescriptions[0] will contain one of the following corresponding to OperationalStatus[0]: StatusDescriptions IML log has no critical or degraded
Property Name LogState Property Implementation 2 (Normal) 2 (Wraps When Full) The IML entries will fill up available IML non-volatile OverwritePolicy memory space until no room is left. The oldest log entries will then be deleted as needed to create room for new log entries. CIM_RecordLog InstanceID HPQ:SMX_IMLRecordLog:1 HP_CommonRecordLog TimeOfLastChange Time of last log change. The following table lists the methods implemented for the SMX_IMLRecordLog class.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement IML record log entry Caption Where: is the SMX_IMLLogEntry.RecordID for the event. Description Description based on specific IML log event. IML record log entry ElementName Where: RecordID is the SMX_IMLLogEntry.RecordID for the event. CIM_RecordForLog CIM_LogEntry HPQ:SMX_IMLLogEntry: InstanceID Where: is the IML event number.
Property Name Property Implementation UpdateTimestamp IML log event update time stamp. OccurrenceCount Number of occurrences of this same IML event type. 0 (Unknown) 2 (Information) Severity 3 (Repaired) 4 (Degraded/Warning) 7 (Critical) 0 (Unknown) OSType 36 (Linux) 39 (VMware) SystemSerialNumber System serial number string from SMBIOS. SystemProductID System product ID string from SMBIOS. SystemModel System model number string from SMBIOS.
Method Name Refer to HP Record Log profile (P00109). Repair 1-2-3 Method Implementation SMX_IMLLogManagesRecord Class The SMX_IMLLogManagesRecord class implements the HP_LogManagesRecord class and associates instances of SMX_IMLRecordLog and SMX_IMLLogEntry. The following table lists the properties implemented.
1-3 Supported indications There are no indications specific to the profile registration implementation.
1 HP Insight Management WBEM IPMI Record Log Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Intelligent Platform Management Interface (IPMI) Record Log provider supports system logs available on HP servers. These logs are called the System Event Log (SEL) and the Forward Progress Log (FPL) and contain informational, warning, and critical event information about a server’s performance and sensors.
Provider Insight Management WBEM support.
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace. Schema Supported by the Provider This provider supports the following classes: • SMX_FPLRecordLog • SMX_FPLLogEntry • SMX_FPLLogManagesRecord • SMX_FPLUseOfLog • SMX_SELRecordLog • SMX_SELLogEntry • SMX_SELLogManagesRecord • SMX_SELRecordLogIndication • SMX_SELUseOfLog The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation CIM_ManagedElement Caption FPL record log Description Forward Progress Log ElementName FPL record log CIM_ManagedSystemElement Name FPL record log OperationalStatus[0] indicates whether the FPL log is in good health OperationalStatus and accepting new FPL entries.
Property Name Property Implementation CurrentNumberOfRecords Number of records in the FPL log (SMX_FPLLogEntry instances) LogState 2 (Normal) 2 (Wraps When Full) The FPL entries fill up available FPL non-volatile memory OverwritePolicy space until no room is left. The oldest log entries are then be deleted as needed to create room for new log entries.
Property Name Property Implementation Description Same as Caption. ElementName Same as Caption. CIM_RecordForLog CIM_LogEntry InstanceID HPQ: LogInstanceID SMX_FPLRecordLog.InstanceID LogName SMX_FPLRecordLog.Name RecordID FPL event number HP_CommonLogEntry RawData FPL log event raw data array MajorClass 11 (FPL) MinorClass 2 (None) System serial number string from SMBIOS. SystemSerialNumber For example: USE4822L0H System model number string from SMBIOS.
The following table lists implemented methods for the SMX_FPLLogEntry class. Method Name Method Implementation See the HP Record Log profile. Repair SMX_FPLLogManagesRecord Class 1-2-3 The SMX_FPLLogManagesRecord class implements the HP_LogManagesRecord class and associates instances of HP_RecordLog and HP_LogEntry. The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Property Implementation CIM_Dependency CIM_UseOfLog HP_UseOfLog Antecedent References SMX_FPLRecordLog Dependent References SMX_ComputerSystem 1-2-5 SMX_SELRecordLog Class The SMX_SELRecordLog class implements the HP_CommonRecordLog class to model the server management record log. The following table lists the properties implemented.
Property Name Property Implementation StatusDescriptions[0] will contain the following value corresponding to StatusDescriptions OperationalStatus[0]: OK HealthState 5 (OK), when OperationalStatus[0]=2 (OK) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 5 (Not Applicable) EnabledDefault 2 (Enabled) CIM_Log MaxNumberOfRecords Number of records available in NVRAM.
Property Name TimeOfLastChange Property Implementation Time of last log change. The following table lists implemented methods for the SMX_SELRecordLog class. Method Name Method Implementation ClearLog See the HP Record Log profile. RepairAll See the HP Record Log profile. 1-2-6 SMX_SELLogEntry Class The SMX_SELLogEntry class implements the HP_CommonLogEntry class to model logs records within the SEL log.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement SEL record log entry Caption Where: RecordID is the SMX_SELLogEntry.RecordID for the event. Description Same as Caption. ElementName Same as Caption. CIM_RecordForLog CIM_LogEntry InstanceID HPQ: LogInstanceID SMX_SELRecordLog.InstanceID LogName SMX_SELRecordLog.Name RecordID SEL event number.
Property Name Property Implementation System model number string from SMBIOS. SystemModel For example: server rx6600 SystemName Computer system name.
The following table lists implemented methods for the SMX_SELLogEntry class. Method Name Method Implementation See the HP Record Log Profile. Repair SMX_SELLogManagesRecord Class 1-2-7 The SMX_SELLogManagesRecord class implements the HP_LogManagesRecord class and associates instances of HP_RecordLog and HP_LogEntry. The following table lists the properties implemented.
Dependent 1-3 References SMX_ComputerSystem Provider Indications 1-3-1 SMX_SELRecordLogIndication Class The SMX_SELRecordLogIndication class implements and extends the HP_CommonRecordLogIndication class to Alert Clients to to new WBEM events found in the SEL Record log.
Property Name Property Implementation Any of 30 Supported WBEM Event Categories: EventCategory 0-9, 11,14,16,18, 20-21, 23,25,28, 33-34, 39, 40-43, 45-46 EventID Valid specific WBEM Event Number. ProviderName FPL_IndicationProvider Provider Version in the format VV.UU.FF. ProviderVersion For example: 02.03.10 NetworkAddresses Contains a list of all the IP addresses or hostname of the computer system generating the indication.
Property Name Property Implementation SystemModel Model name of the computer system generating the indication. SystemGUID Platform GUID of the computer system generating the indication. SystemVirtualUUID[] If Synergy is enabled, this will contain the logical UUID for the system. SystemVirtualSerialNumber[] If Synergy is enabled, this will contain the logical Serial Number for the system. EnclosureName HP_BladeEnclosureCS.
Property Name Property Implementation Indexed arrays VariableNames[0] per VariableValues[0] per VariableTypes[0], any or all of the following values: “IPMIEventHex” “DataFieldTypeName” VariableNames “DecodedDataFiled” “ReportingEntityID” “ReportingEntityFullName” “IPMIEventID” “SWID” VariableTypes 1 For VariableNames “IPMIEventHex”: This will be hex string representing the IPMIEvent For VariableNames “DataFieldTypeName”: This will contain text Physical Location For VariableNames “DecodedDataFiled”: “Ph
Property Name Property Implementation Value will contain hex string representation of SystemGUID 8-Byte Physical Location blob represented as a string HWPhysicalLocation For example: “00-ff-ff-ff-ff-05-ff-64” HP Insight Management WBEM IPMI Record Log Provider Overview 18
1 HP Insight Management WBEM Management Processor Lite Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Management Processor Lite provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization HP Management Processor (MP) Lite HP WBEM TC Profile Version 2.1.
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
Property Name Property Implementation CIM_ManagedElement Short Description of the Management Processor, including the product name and the enabled state of the MP. For example: Product name of the management processor in the format: (X) Where: is the name of the MP product and (X) indicates whether the MP is Active or Inactive/Disabled.
Property Name Property Implementation Name of the Management Processor, including the product name and the enabled state of the MP. For example: Product name of the management processor in format: (X) Where: is the name of the MP product.
Property Name Property Implementation Enumerators indicating the Management Processor operational status (refer to OperationalStatus mapping table in HP Management Processor Lite Profile for specific descriptions of when each value is populated).
Property Name Property Implementation Descriptive text per OperationalStatus.
Property Name Property Implementation CIM_EnabledLogicalElement 2 (Enabled) for active MP 3 (Disabled) for inactive/disabled MP EnabledState Note: The Active MP may be enabled or disabled (the user can manually disable the MP via RBSU settings). The Inactive MP is always disabled. RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_System CreationClassName SMX_ManagementProcessor Name Opaque instance identifier using HPQ as the OrgID.
Property Name Property Implementation Enumerator indicating the model or type of management processor.
Property Name Property Implementation The IP address of the MP-resident network interface. Note: IPAddress When a Management Processor is disabled (refer to property EnabledState) IP Address will always be reported as 0.0.0.0. Network communication with the MP is not possible when the MP is disabled. The Uniform Resource Locator of the management processor controller’s web-based user interface.
Property Name Property Implementation the MP is disabled. Enumerator indicating the license type of the Management Processor. 0 (Unknown) 1 (None) 2 (iLO Advanced) ActiveLicense 3 (iLO Light) 4 (iLO Advanced for Blade System) 5 (iLO standard for Blade System) Note: When communication failure with MP occurs then ActiveLicense is Unknown. If no license present then ActiveLicense is None.
Property Name Property Implementation a valid IPv6 subnet IPv4Address The IPv4 address of the management processorcontroller’s NIC if one is defined IPv4SubnetMask The mask for the IPv4 address of the management processorcontroller’s NIC if an IPv4 address is defined PermanentAddress The permanent network address or MAC that is hard-coded for the management processor controller’s NIC GatewayIPAddresses[] The IPv4 and IPv6 addresses which define the default IPv4 and/orIPv6 gateways for the managemen
Property Name Property Implementation RI9 for iLO 3 RI10 for iLO 4 Lights Out 100 (LO100) CIM_ManagedSystemElement Product name of the management processor.
Property Name Property Implementation Manufacturer Hewlett-Packard Classifications 10 (Firmware) ClassificationDescriptions HP Management Processor Firmware Indexed array that provides the values described by the type information stored in the corresponding component of the IdentityInfoType array.
Property Name Property Implementation CIM_ManagedElement Description Description of the class, for example: HP Management Processor Collection ElementName for the class ElementName For example: Management Processor Collection CIM_Collection CIM_SystemSpecificCollection Opaque instance identifier using HPQ as the OrgID.
Property Name Property Implementation GroupStatusDescriptions[0] text per GroupOperationalStatus[0]: Aggregate Management Processor Collection Status: Unknown GroupStatusDescriptions Aggregate Management Processor Collection Status: OK Aggregate Management Processor Collection Status: Degraded Aggregate Management Processor Collection Status: Error SMX_MPCollection 1-2-4 SMX_MPHostedCollection Class The SMX_MPHostedCollection class implements the HP_MPHostedCollection class, which associates a manageme
The following table lists the properties implemented. Property Name Property Implementation CIM_Component CIM_SystemComponent CIM_ComponentCS HP_MPComponentCS GroupComponent References SMX_ComputerSystem PartComponent References SMX_ManagementProcessor SMX_MPMemberOfCollection Class 1-2-6 The SMX_MPMemberOfCollection class implements the HP_MPMemberOfCollection class to associate a management processor to the collection to which it belongs. The following table lists the properties implemented.
SMX_MPElementFirmwareIdentity Class 1-2-7 The SMX_MPElementFirmwareIdentity class implements the HP_MPElementFirmwareIdentity class to associate a management processor to its corresponding firmware. The following table lists the properties implemented.
InstalledSoftware 1-2-9 References SMX_MPFirmware SMX_MPConsolidatedStatusView Class HP_ConsolidatedStatusView extends the class CIM_View instances are used to aggregate and model all Consolidated Status information into a instances related to a single subsystem. If consolidated View Classes are implemented, there shall be one instance of HP_ConsolidatedStatusView for each instance of HP_GroupSystemSpecificCollection.
CIM_ManagedSystemElement Included MemberObjectPaths[] 1-2-10 Object path references to each CIM_ManagedSystemElement member of this collection SMX_MPScopedConsolidatedStatusView Class HP_ScopedConsolidatedStatusView extends the class CIM_ScopedView for use with HP_ComputerSystem and HP_ConsolidatedStatusView. There shall be one instance of HP_ScopedConsolidatedStatusView implemented for each HP_ConsolidatedStatusView instance. .
Property Name Property Implementation Short Description of the Management Controller, including the product name and the enabled state of the MP. For example: Product name of the management controller in the format: (X) Where: is the name of the MP product and (X) indicates whether the MP is Active or Inactive/Disabled.
Property Name Property Implementation Integrated Lights Out 2 (iLO 2) (Inactive) Integrated Lights Out 2 (iLO 2) (Inactive) Integrated Lights Out 3 (iLO 3) (Active) Integrated Lights Out 4 (iLO 4) (Active) Remote Insight Board Lights Out Edition II (RILOE-II) Light Out 100 (LO100) (Active) CIM_ManagedSystemElement Enumerators indicating the Management Controller operational status (refer to OperationalStatus mapping table in HP Management Processor Lite Profile for specific descriptions of when each value
Property Name Property Implementation Descriptive text per OperationalStatus.
Property Name Property Implementation 2 (Enabled) for active MP 3 (Disabled) for inactive/disabled MP EnabledState Note: The Active MP may be enabled or disabled (the user can manually disable the MP via RBSU settings). The Inactive MP is always disabled. RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice CreationClassName SMX_ManagementController SystemCreationClassName SMX_ComputerSystem SystemName Value of SMX_ComputerSystem.
SMX_MPControllerMP GroupComponent References SMX_ManagementProcessor PartComponent References SMX_ManagementController 1-2-13 SMX_MPControllerPCIDevice Class The SMX_MPControllerPCIDevice class implements the CIM_ConcreteIdentity class to associate a management controller to its corresponding PCI Devices. The following table lists the properties implemented.
Property Name Property Implementation CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown. SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication Provider Version in the format VV.UU.FF. ProviderVersion NetworkAddresses For example: 01.05.00 Contains a list of all the IP addresses of the computer system generating the indication.
Property Name Property Implementation system. SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v.. EnclosureName HP_BladeEnclosureCS.Name RackName Rack name if one exists RackUUID Rack Unique Identifier if one exists BladeName HP_ComputerSystem.Name BladeBay HP_BladeCSLocation.
Property Name Property Implementation Description HP_GroupSystemSpecificConsolidated operational status policy has been modified to monitor operational status from different set of managed elements.
1-3-3 OK HP_AlertStatusIndication: Consolidated Status Changed- The following table describes one of the conditional Consolidated Status Changed indications. These Consolidated Status Changed indications shall be implemented if not all managed elements associated to an HP_GroupSystemSpecificCollection support the device status changed indications.
Property Name Property Implementation EventCategory 1 (Other) OtherEventCategory “View Class Status Changed” ProbableCause 1 (Other) “Operational Status of participating members in this collection have transitioned to OK from Degraded or Error state. These Operational Status ProbableCauseDescription changes could have also affected the HP_GroupSystemSpecificCollection’s operational status.
Property Name Property Implementation of the HP_GroupSystemSpecificCollection.. AlertingElementFormat 2 (CIMObjectPath) AlertType 7 (Model Alert) EventID “3” ProviderName “HP MP” RecommendedActions “Inspect this View Class MemberOperationalStatus, MemberStatusIncluded and MemberObjectPath arrays to indict degraded or failing collection members.” HP_AlertIndication Summary “Consolidated View Class Collection operational status has transitioned to Degraded.
should not be implemented. If HP_ConsolidatedStatusView is not implemented, then AlertingManagedElement shall represent the CIM Object Path of the HP_GroupSystemSpecificCollection instance. Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description Consolidated View Class Collection operational status has transitioned to error. AlertingManagedElement CIM Object Path of the HP_ConsolidatedStatusView instance if implemented.
Property Name Property Implementation “Operational Status of participating members in this collection have transitioned to Error state ProbableCauseDescription and caused operational status for the for the collection to transition to Error.
1 HP Insight Management WBEM PCI Device Provider Overview Description Implemented Profiles 1-1 The HP Insight Management Web-Based Enterprise Management (WBEM) PCI Device provider implements the profiles listed to support PCI devices installed on HP servers. The following table details the profiles implemented and files installed by this provider. • DMTF: PCI Device Profile (DSP1075) 1.0.0a 09/2007 • DMTF: Physical Asset Profile • HP: Location Profile 1.2.
Property Name Name Property Implementation A hardware ID for this PCI device provided by the operating system. CIM_LogicalDevice CreationClassName “SMX_PCIDevice” DeviceID Unique identifier for this PCI device instance. SystemCreationClassName SMX_ComputerSystem.CreationClassName SystemName SMX_ComputerSystem.
Property Name Property Implementation DeviceNumber The device number assigned to this PCI device for the bus. FunctionNumber The function number for this PCI device. PCIDeviceID PCI device ID as described in the configuration registers for this PCI device. Revision ID as described in the configuration registers for this PCI device.
Property Name Property Implementation “PCI Card ” Name CIM_PhysicalElement CreationClassName “SMX_PCICard” Tag “PCI Card ” Description “PCI Card ” ElementName “PCI Card ” CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) PackageType 9 (Module/Card) VendorCompatibilityStrings “HPQ:PCICard” CIM_Card HostingBoard False HP_PCICard 1-2-3 SMX_PCISlot Property Name Property Implementation CIM_ManagedElement Caption Same as Name.
Property Name Property Implementation Refer to “Physical Location” for more information. CIM_PhysicalElement CreationClassName “SMX_PCISlot” Tag Opaque Key. HPQ:SMX_PCISlot: Description Same as Name. ElementName Same as Name.
Property Name Property Implementation Only initialized if ConnectorType == 1 (Other): ConnectorDescription “PCI Express” – if this is a PCI Express slot or “PCI Express Mezzanine” if mezzanine slot in a blade, otherwise this property is not set OtherTypeDescription Deprecated in favor of ConnectorDescription CIM_Slot The physical PCI slot number Number True – if slot supports PCI hot plug operations SupportsHotPlug False – if slot does not support PCI hot plug operations VendorCompatibilityStrings
1-2-6 SMX_SystemPCISlot Property Name Property Implementation GroupComponent References SMX_ComputerSystemChassis PartComponent References SMX_PCISlot 1-2-7 SMX_SystemPCIDevice Property Name Property Implementation GroupComponent References SMX_ComputerSystem PartComponent References SMX_PCIDevice 1-2-8 SMX_PCISlotLocation Property Name Property Implementation CIM_ManagedElement Caption Same as ElementLocationTag. Description Same as ElementLocationTag.
Property Name Property Implementation HP_Location ElementLocationTagDesc 0 (Hood Tag) "PCI Slot Location" . ElementLocationTag Refer to “Physical Location” for more information.
Array of numerical enumerators describing values at comparable index in the LocationInformation array index 1,2, 3, or 4. LocationInfoDesc[0] per LocationInformation[0] 3 (PCI Slot). Additional enumerators for Cellular servers LocationInfoDesc 7 (Cabinet) 6 (Chassis) Additional enumerators for HP BladeSystem servers 14 (Blade) 1 (Mezzanine) LocationInformation Array of text values representing the location components that describe this PCI Slot location. LocationInfoDesc[0] per LocationInfornation[0].
All Systems Slot= HP Integrity Cellular Servers HP BladeServers in C3000 / C7000 Enclosures Cabinet= Blade= Embedded Controller= Bay= RootPort= (if embedded on System Board) Mezzanine= Chassis= Mezzanine= (I/O Mezzanine slot num) 1-4 Provider Indications Indications Generated by the Provider This provider generates no indications.
1 HP Insight Management Power Supply Provider Overview The HP Insight Management Web-Based Enterprise Management (WBEM) Power Supply provider implements the HP Power Supply profile to model power supplies in servers. Description This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Power Supply Profile HP WBEM TC 1.3 (P103) HP Location Profile HP WBEM TC 1.2.0 (P124) HP Power Supply Physical Asset Profile HP WBEM TC 1.0.
Configuring the Provider 1-2 This provider does not accept specific configuration adjustments beyond standard HP Insight Management WBEM support. Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the property name (including type and units) and the second column describes how the provider determines the properties implementation. When the property implementation value is a number, the number given is the default behavior and the Managed Object Format interpretation is within parenthesis.
Property Name Property Implementation For example: Power Supply1 at PowerSupplySlot=2, Power Supply 1a at PowerSupplySlot=2 CIM_ManagedSystemElement 2 (OK) – if power supply is operating properly; OperationalStatus[0] 3 (Degraded) – if power supply is degraded; 6 (Error) – if power supply has failed OperationalStatus[1] Extended Warning and Error status. See the MOF and Profile Description of the status of the power supply corresponding to the OperationalStatus.
Property Name TimeOfLastStateChange Property Implementation Time that state last changed for power supply. 0 if it has not changed since provider startup. CIM_LogicalDevice CreationClassName SMX_PowerSupply DeviceID Unique identifier for this power supply instance. SystemCreationClassName SMX_ComputerSystem.CreationClassName SystemName SMX_ComputerSystem.
Property Name Property Implementation CIM_ManagedElement Power Collection Caption This is a collection of all devices including power supplies that provide power. GroupStatusDescription. Description Where: GroupStatusDescription represents the value of the GroupStatusDescriptions[0] property.
Property Name Property Implementation Unknown status for power supplies - if GroupOperationalStatus[0] is 0 (Unknown); Power supplies are operating properly if GroupOperationalStatus[0] is 2 (OK); GroupStatusDescriptions[0] Power supplies are degraded if GroupOperationalStatus[0] is 3 (Degraded); Power supplies have failed if GroupOperationalStatus[0] is 6 (Error) 1-2-3 SMX_PowerRedundancySet Class The SMX_PowerRedundancySet class is used to model power supply redundancy sets on servers.
Property Name Property Implementation CIM_SystemSpecificCollection InstanceID Unique identifier for this power redundancy instance. CIM_RedundancySet MaxNumberSupported Represents the maximum number of power supplies supported for this redundancy set. MinNumberNeeded Represents the minimum number of power supplies needed to function.
The following table lists the properties implemented. Property Name Property Implementation Collection References HP_PowerRedundancySet Included Writable Boolean property indicating if the power supply instance referenced by Member will contribute status to the HP_PowerCollection. Property can be modified using the ModifyInstance() intrinsic method.
True: Include member status in collection status False: Do not include member status in collection status Member References HP_PowerSupply 1-2-7 SMX_HostedPowerCollection Class The SMX_HostedPowerCollection class is used to represent an association between the HP_PowerCollection class and the computer system that contains this collection. The following table lists the properties implemented.
Property Name Property Implementation Name of this power supply from the name displayed by the MP or iLO and its location. Caption For example: Power Supply1 at PowerSupplySlot=2 Description of this power supply location, including the location. Description For example on HP Proliant: The location of the power supply . Please refer to power supply position printed on the system. Where: presents the power supply position printed on the system labeling.
Property Name LocationInformation Property Implementation An array of string values describing the location path of a managed element containment hierarchy. 1-2-10 SMX_PowerSupplyElementLocation Class The SMX_PowerSupplyElementLocation class is used to represent an association between the CIM_Location and CIM_ManagedElement classes. The following table lists the properties implemented.
Property Name Property Implementation Description of this power supply module, including ElementName, Type and Status. Description For example: ElementName provides power for PowerSupplyType. StatusDescription Where: ElementName represents the value of ElementName, PowerSupplyType represents the corresponding string value of the PowerSupplyType enumeration and StatusDescription represents the value of StatusDescriptions[0].
Property Name Property Implementation 20 (Major Failure) – if power supply has failed Short description of this power supply for the name displayed by the MP or iLO and its location. Name For example: Power Supply1 at PowerSupplySlot=2, Power Supply 1a at PowerSupplySlot=2 CIM_PhysicalElement CreationClassName SMX_PowerSupplyModule PartNumber The part number assigned by the organization that is responsible for producing or manufacturing the PhysicalElement.
GroupComponent References HP_ComputerSystemChassis PartComponent References HP_PowerSupplyModule 1-2-13 SMX_RealizesPowerSupply Class The SMX_RealizesPowerSupply class extends the CIM_Realizes class and associates the HP_PowerSupply instance with HP_PowerSupplyModule instances.
The following table lists the properties implemented. Property Name Property Implementation Antecedent References HP_PowerSupplyModule Dependent References HP_PowerSupply 1-2-14 SMX_PowerSupplySlot Class The SMX_PowerSupplySlot class is used to model physical power supply slots on servers. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Short description of this power supply slot.
Property Name Property Implementation For example: PowerSupplySlot=2 CIM_PhysicalElement CreationClassName SMX_PowerSupplySlot Tag Unique identifier for this power supply slot. CIM_PhysicalPackage ConnectorLayout 6 (Slot) Number Where: represents the number of the power supply slot. 1-2-15 SMX_SystemPowerSupplySlot Class The SMX_SystemPowerSupplySlot class extends the CIM_Container class and association of the HP_ComputerSystemChassis instance with HP_PowerSupplySlot.
Dependent References HP_PowerSupplyModule 1-2-17 SMX_Power Meter SMX_PowerMeter is used to model power utilization on Servers. Please note: power supply numbers for existing instances do not change when other power supplies are added and removed. Not all systems support reporting power utilization . Property Name Property Implementation CIM_ManagedElement Short description of this power utilization sensor using the name of the power supply displayed by the MP or iLO and its location.
Property Name Property Implementation Description of the status of the power utilization sensor corresponding to the OperationalStatus. StatusDescriptions[0] For example: Power Supply is operating properly – if OperationalStatus[0] is 2 (OK); HealthState 5 (OK) – if power utilization sensor is operating properly; Short description of this power utilization sensor using the name of the power supply displayed by the MP or iLO and location.
Property Name Property Implementation Array may contain the following value: PossibleStates PossibleStates[0] = “Normal” CIM_NumericSensor CurrentReading Current reading of the power meter BaseUnits 7 (Watts) RateUnits 0 (None) UnitModifier 0 1-2-18 SMX_SystemPowerMeter SMX_SystemPowerMeter class and associates the HP_ComputerSystem instance with HP_PowerMeter.
Property Name Property Implementation CIM_ManagedElement Caption Power controller firmware Description of this power utilization sensor including the Caption and StatusDescriptions. Description For example: Power controller firmware.
Property Name Property Implementation ClassificationDescriptions Power controller firmware IsEntity TRUE VersionString The firmware version string MajorVersion The firmware major version number, if any MinorVersion The firmware minor version number, if any RevisionNumber The firmware revision number number, if any 1-2-21 SMX_PowerControllerElementFirmwareIdentity The SMX_PowerControllerElementFirmwareIdentity class associates the HP_ComputerSystem instance with HP_PowerControllerFirmware.
1-3 Provider Indications Indications Generated by the Provider The following tables describe the SMX WBEM Power Supply Provider indications that are implemented for HP ProLiant server platforms where available. HP Integrity server platforms implement power supply related indications in the SMX IPMI Record Log provider. 1-3-1 Provider Indication Common Properties Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication.
Property Name Property Implementation SystemFirmwareVersion Array of firmware versions of the computer system generating the indication. SystemSerialNumber Serial number of the computer system generating the indication. SystemProductID Product ID of the computer system generating the indication. SystemModel Model name of the computer system generating the indication. SystemGUID Platform GUID of the computer system generating the indication.
Property Name Property Implementation CIM_AlertIndication A power supply has failed – input power lost. PowerSupplyCaption Description Where: PowerSupplyCaption is the SMX_PowerSupply.
Property Name Property Implementation CIM_AlertIndication A power supply has been removed. PowerSupply Description Where: PowerSupply is the system power supply that was removed. AlertingManagedElement WBEM Path of the SMX_PowerSupply instance. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 1 ProviderName HP Power RecommendedActions Check the system power supply configuration. Verify that this power supply was removed intentionally.
Property Name Property Implementation A power supply has been inserted. PowerSupplyCaption Description Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for the power supply that has been inserted. AlertingManagedElement WBEM Path of SMX_PowerSupply instance representing the inserted power supply. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 2 ProviderName HP Power RecommendedActions No action is recommended.
Property Name Property Implementation A power supply has failed. PowerSupplyCaption Description Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for the power supply that has failed. AlertingManagedElement WBEM Path of SMX_PowerSupply instance representing the failed power supply. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 3 ProviderName HP Power RecommendedActions Check the failed power supply and replace if necessary.
Property Name Property Implementation A power supply has failed. PowerSupplyCaption Description Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for the power supply that has degraded. AlertingManagedElement WBEM Path of SMX_PowerSupply instance representing the degraded power supply. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 20 ProviderName HP Power RecommendedActions Check the degraded power supply and replace if necessary.
Property Name Property Implementation power supply has been repaired. PowerSupplyCaption Description Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for the power supply that has been repaired. AlertingManagedElement WBEM Path of SMX_PowerSupply instance representing the repaired power supply. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 4 ProviderName HP Power RecommendedActions No action is recommended.
Property Name Property Implementation A fault tolerant power supply is no longer providing power for a power redundancy set. RedundancySetCaption Description Where: RedundancySetCaption represents the SMX_PowerRedundancySet.Caption for the redundancy set with reduced redundancy. AlertingManagedElement WBEM Path of SMX_PowerRedundancySet instance representing the redundancy set with reduced redundancy.
Property Name Property Implementation Power redundancy has been lost. RedundancySetCaption Description Where: RedundancySetCaption represents the SMX_PowerRedundancySet.Caption for the redundancy set that lost redundancy. AlertingManagedElement WBEM Path of SMX_PowerRedundancySet.Caption instance representing the redundancy set where redundancy was lost.
Property Name PerceivedSeverity Property Implementation 5 (Major) CIM_AlertIndication Power redundancy has been lost. RedundancySetCaption Description Where: RedundancySetCaption represents the SMX_PowerRedundancySet.Caption for the redundancy set that failed redundancy. AlertingManagedElement WBEM Path of SMX_PowerRedundancySet instance representing the redundancy set where redundancy failed.
1-3-11 HP_DeviceIndication: Power Supply Redundancy Restored Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Power redundancy for the system has been restored. RedundancySetCaption Description Where: RedundancySetCaption is SMX_PowerRedundancySet.Caption of the redundancy set the power redundancy set with restored redundancy.
1 HP Insight Management WBEM Profile Registration Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Management Profile Registration provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Profile Registration Profile (P00100) HP WBEM TC 2.0.
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace. Schema Supported by the Provider This provider supports the following classes: • SMX_RegisteredProfile • SMX_ExtendsProfile • SMX_ReferencedProfile • SMX_PRPBaseServerECTP • SMX_FCPBaseServerECTP The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation 3 (SLP) AdvertiseTypes HPQ: InstanceID Where: : is a unique number. None for DMTF profiles OtherRegisteredOrganization None for SNIA SMI-S storage profiles. "HP WBEM TC" for HP extension profiles. RegisteredName The DMTF Profile table lists the property values for this class.
OS Status 1.0.0 DMTF OS Status Profile Record Log 1.0.0 DMTF Record Log Profile Ethernet Port 1.1.0 DMTF Ethernet Port Profile IP Interface 1.0.1 DMTF IP Interface Profile Sensors 1.0.1 DMTF Sensors Profile PCI Device 1.0.0 DMTF PCI Device Profile Software Inventory 1.0.0 DMTF Software Inventory Profile Profile Registration 1.0.0 DMTF Profile Registration Profile The following table lists all possible SNIA Profiles.
The following table lists all possible HP WBEM TC Profiles. Some implementations only support a subset of these profiles so only the subset is reported. RegisteredName Registered Version Caption/Description/ElementName HP Base Server 2.0.0 HP Base Server Profile HP CPU 1.1.0 HP CPU Profile HP Fan 1.3.0 HP Fan Profile HP Power Supply 1.3.0 HP Power Supply Profile HP System Memory 1.0.0 HP Memory Profile HP Base Server Physical Asset 1.4.
RegisteredName Registered Version Caption/Description/ElementName HP Storage Enclosure 1.0.2 HP Storage Enclosure Profile HP Profile Registration 2.0.0 HP Profile Registration Profile HP Smart Array 2.6.0 HP Smart Array Profile HP SAS HBA 2.0.0 HP SAS HBA Profile 1-2-2 SMX_ExtendsProfile Class The SMX_ExtendsProfile class extends the CIM_Dependency class and associates an extension profile registration and the parent profile it extends. The following table lists the properties implemented.
Dependent 1-2-4 References CIM_RegisteredProfile (referenced) SMX_PRPBaseServerECTP Class The SMX_PRPBaseServerECTP class extends the CIM_ElementConformsToProfile class and associates the Base Server registered profile with the HP specific central class that defined the implementation of the profile. The following table lists the properties implemented.
1-3 Provider Indications Indications Generated by the Provider This provider generates no indications.
SAS HBA Provider Datasheet version 1.05 The following chapters define the supported properties for the SAS HBA provider. For details of each property, see the HP SAS HBA profile (P00122) and associated MOF file. 1-1-1 SMX_SASArraySystem SMX_SASArraySystem represents the top level system. There is one instance per HBA.
SMX_SASArrayController represents the controller. There is one per HBA.
Table 16-3 Class: SMX_SASStorageVolume (CIM_StorageVolume) Property name Property implementation Name Concatenation of Vendor + Model + SerialNumber+Logical Drive number For example, HP+HP 8 INT Port SAS/SATA HBA+C007760405+LD1 CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASStorageVolume DeviceID Opaque Key SystemCreationClassName SMX_SASArraySystem SystemNa
Table 16-3 Class: SMX_SASStorageVolume (CIM_StorageVolume) Property name Property implementation OperationalStatus[0] Volume status • 0 (Unknown) • 2 (OK) • 3 (Degraded) - RAID redundancy lost or rebuilding data • 6 (Error) OSName 1-1-4 Corresponding OS name for this volume SMX_SASDiskDrive SMX_SASDiskDrive represents the hard drives connected to SAS HBA controllers.
Table 16-4 Class: SMX_SASDiskDrive (CIM_DiskDrive) Property name Property implementation SMX_SASDiskDrive DriveConfiguration See HP SAS HBA Profile DriveHasMNPData See HP SAS HBA Profile DriveInterface See HP SAS HBA Profile DrivePlacement See HP SAS HBA Profile DriveRotationalSpeed See HP SAS HBA Profile Description • Unknown (If neither SAS or SATA) • SAS (If disk drive interface is SAS) • SATA (If disk drive interface is SATA) NegotiatedDataWidth 0 NegotiatedSpeed 0 This value indicate
Table 16-5 Class: SMX_SASStorageExtent (CIM_StorageExtent) Property name Property implementation OperationalStatus[0] Operational Status for the disk drive • • • • 0 (Unknown) 2 (OK) 5 (Predictive Failure) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASStorageExtent DeviceID Opaque ID SystemCreationClassName SMX_SASArraySystem SystemName SMX_SAS
Table 16-6 Class: SMX_SASDiskDriveFirmware (CIM_SoftwareIdentity) Property name Property implementation ElementName TargetType value CIM_ManagedSystemElement Name Disk Drive Firmware CIM_LogicalElement Caption Disk Drive Firmware Description Disk Drive Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Disk Drive Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Disk drive vendor string IdentityInfoType [0]CIM:SoftwareFamily [1]HPQ:SoftwareCategory Id
Table 16-7 Class: SMX_SASPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CreationClassName SMX_SASPhysicalPackage Manufacturer Controller vendor string Model Controller model string PartNumber N/A–Not available for this implementation SerialNumber Controller Serial Number Tag HBA Serial number CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) SMX_SASPhysicalPackage 1-1-8 SMX_SASDiskPhysicalPackage SMX_SASDiskPhysicalPackage represents the physical aspects
Table 16-8 Class: SMX_SASDiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation HotSwappable • TRUE—Drive is hot swappable • FALSE—Drive is not hot swappable RemovalConditions • • • • 0 (Unknown) 2 (Not Applicable) 3 (Removable when off) 4 (Removable when on or off) SMX_SASDiskPhysicalPackage 1-1-9 SMX_SASPortController SMX_SASPortController represent the HBA in the host system. There is one instance per HBA.
SMX_SASDAPort represents the front-end port for an HBA in the host system. Direct Attached implies that the array controller is attached to a local bus on the host (for example, PCI).
Table 16-11 Class: SMX_SASFirmware (CIM_SoftwareIdentity) Property name Property implementation CIM_ManagedSystemElement Name HBA Firmware CIM_LogicalElement Caption HBA Firmware Description HBA Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] HBA Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Controller Vendor string IdentityInfoType [0]CIM:SoftwareFamily [1] HPQ:SoftwareCategory IdentityInfoValue [0]HPQ: Set to controller model
Table 16-12 Class: SMX_SASPrimordialPool (CIM_StoragePool) Property name Property implementation RemainingManagedSpace 0 TotalManagedSpace Total raw space available to controller. This is calculated by summing the total space on all raid drives connected to this controller. SMX_SASPrimordialPool SMX_SASPrimordialPoolNoRaid 1-1-13 SMX_SASPrimordialPoolNoRaid represents the total raw storage managed by the array controller that is not assigned to raid volumes.
Table 16-14 Class: SMX_SASStoragePool (CIM_StoragePool) Property name Property implementation ElementName Controller name and location: pool identifier For example, HP 8 INT Port SAS/SATA HBA in Slot 3: Storage Pool CIM_ManagedSystemElement CIM_LogicalElement CIM_StoragePool InstanceID Opaque key PoolID Controller serial number:1 Primordial FALSE RemainingManagedSpace 0 TotalManagedSpace Total raw space managed by this pool SMX_SASStoragePool 1-1-15 SMX_SASStorageSetting SMX_SASStorageSettin
Table 16-15 Class: SMX_SASStorageSetting (CIM_StorageSetting) Property name Property implementation DeltaReservationMin 0 NoSinglePointOfFailure • FALSE—RAID 0 • TRUE—RAID 1 PackageRedundancyGoal • 0 (RAID 0) • 1 (RAID 1) PackageRedundancyMax • 0 (RAID 0) • 1 (RAID 1) PackageRedundancyMin • 0 (RAID 0) • 1 (RAID 1) SMX_SASStorageSetting SMX_SASSCSIProtocolEndpoint 1-1-16 SMX_SASSCSIProtocolEndpoint represents an access point to storage resources.
Table 16-16 Class: SMX_SASSCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation Role 4 (Both Initiator and Target) SMX_SASSCSIProtocolEndpoint 1-1-17 SMX_SASSCSIProtocolController SMX_SASSCSIProtocolController represents a view a SCSI resources on the controller.
Table 16-18 Class: SMX_SASStorageRedundancySet (CIM_StorageRedundancySet) Property name Property implementation CIM_ManagedElement ElementName Storage Redundancy Set CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque key CIM_RedundancySet LoadBalanceAlgorithm 2 (No Load Balancing) MaxNumberSupported 0 MinNumberNeeded 0 RedundancyStatus • 2 (Fully Redundant) • 4 (Redundancy Lost) TypeOfSet[0] 5 (Limited Sparing) CIM_StorageRedundancySet SMX_SASStorageRedundancySet 1-1-19 SMX_SASS
SMX_SASArraySystemLocation 1-1-20 SMX_SASArraySystemLocation represents a location string for the HBA.
Table 16-21 Class: SMX_SASDiskDriveLocation (HP_Location) Property name Property implementation CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag Bay Number or SCSI ID of Disk ElementLocationTagDesc 20 (Bay) or 21 (SCSI ID) SMX_SASDiskDriveLocation 1-1-22 SMX_SASStorageCapabilities SMX_SASStorageCapabilities represents the possible capabilities of a Storage Pool.
Table 16-22 Class: SMX_SASStorageCapabilities (CIM_StorageCapabilities) Property name Property implementation ElementType 5 (Storage Pool) NoSinglePointOfFailure • True—When number of drives > 1 (For example, Pool can be configured for redundancy.) • False—When number of drives = 1 or Pool is NonRAID • True—When number of drives > 1 (For example, NoSinglePointOfFailureDefault Pool can be configured for redundancy.
SMX_SASDriveCage represents the drive cage assembly and back plane within a storage enclosure. There can be multiple instances within a duplexed enclosure.
Table 16-25 Class: SMX_SASEnclosureFirmware (CIM_SoftwareIdentity) Property name Property Implemenation Name Storage Enclosure Firmware CIM_LogicalElement Caption Storage Enclosure Firmware Description Storage Enclosure Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Storage Enclosure Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Enclosure Vendor string IdentityInfoType [0]CIM:SoftwareFamily [1] HPQ:SoftwareCategory IdentityInfoValue [0]HPQ:
Table 16-26 Class: SMX_SASStorageEnclosure (HP_StorageEnclosure) Property name Property implementation PartNumber N/A—Not available in this implementation SerialNumber Enclosure Serial Number N/A is reported if there is no serial number (for example, internal enclosures).
Table 16-27 Class: SMX_SASStorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName SMX_SASStorageEnclosureProcessor Name Opaque Key NameFormat Other CIM_ComputerSystem Dedicated[0] 2 (Other) IdentifyingDescriptions[0] Other Vendor Specific Name OtherDedicatedDescriptions[0] SDE - indicates Stora
SMX_SASSmartDriveCarrierAppFirmware Class 1-1-29 The SMX_SASSmartDriveCarrierAppFirmware class implements the CIM_SoftwareIdentity class and represents the firmware installed on a Smart Drive Carrier. This class is implemented only when the hardware includes Smart Drive Carrier support. The following table lists the properties implemented.
SMX_SASSmartDriveCarrierBootldrFirmware Class 1-1-30 The SMX_SASSmartDriveCarrierBootldrFirmware class implements the CIM_SoftwareIdentity class and represents the firmware installed on a Smart Drive Carrier Bootloader. This class is implemented only when the hardware includes Smart Drive Carrier support. The following table lists the properties implemented.
SMX_SASDriveCageDiskPhysicalPackage (Association) 1-1-31 Table 16-29 Class: SMX_SASDriveCageDiskPhysicalPackage (CIM_Container) 1-1-32 Property name Property implementation GroupComponent SMX_SASDriveCage PartComponent SMX_SASDiskPhysicalPackage SMX_SASStorageEnclosureDriveCage (Association) Table 16-30 Class: SMX_SASStorageEnclosureDriveCage (CIM_Container) Property name Property implementation GroupComponent SMX_SASStorageEnclosure PartComponent SMX_SASDriveCage SMX_SASStorageEnclosureEnc
SMX_SASStorageEnclosureProcessorEnclosureFirmwar e (Association) 1-1-35 Table 16-33 Class: SMX_SASStorageEnclosureProcessorEnclosureFirmware (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent SMX_SASEnclosureFirmware Dependent SMX_SASStorageEnclosureProcessor ElementSoftwareStatus • ElementSoftwareStatus[0]: 2 (Current) • ElementSoftwareStatus[1]: 6 (Installed) SMX_SASStorageEnclosureStorageEnclosureProcessor (Association) 1-1-36 Table 16-34 Class: SMX_SASStorageEncl
Table 16-36 Class: SMX_SASPrimordialPoolStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation ManagedElement SMX_SASPrimordialPool SMX_SASPrimordialPoolNoRaidStorageCapabilities (Association) 1-1-39 Table 16-37 Class: SMX_SASPrimordialPoolNoRaidStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation Capabilities SMX_SASStorageCapabilities ManagedElement SMX_SASPrimordialPoolNoRaid SMX_SASStoragePoolStorageCapabilities (Association) 1-1
Table 16-40 Class: SMX_SASArraySystemPortController (CIM_Logicaldentity) 1-1-43 Property name Property implementation SameElement SMX_SASArraySystem SystemElement SMX_SASPortController SMX_SASArraySystemDiskDrive (Association) Table 16-41 Class: SMX_SASArraySystemDiskDrive (CIM_SystemDevice) 1-1-44 Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASDiskDrive SMX_SASArraySystemStorageVolume (Association) Table 16-42 Class: SMX_SASArraySystemStorageVol
1-1-47 SMX_SASArraySystemPrimordialPool (Association) Table 16-45 Class: SMX_SASArraySystemPrimordialPool (CIM_HostedStoragePool) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASPrimordialPool SMX_SASArraySystemPrimordialPoolNoRaid (Association) 1-1-48 Table 16-46 Class: SMX_SASArraySystemPrimordialPoolNoRaid (CIM_HostedStoragePool) 1-1-49 Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASPrimordialPoolN
Table 16-49 Class: SMX_SASArraySystemArrayController (CIM_ComponentCS) 1-1-52 Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASArrayController SMX_SASProductPhysicalPackage (Association) Table 16-50 Class: SMX_SASProductPhysicalPackage (CIM_ProductPhysicalPackage) 1-1-53 Property name Property implementation GroupComponent SMX_SASProduct PartComponent SMX_SASPhysicalPackage SMX_SASStoragePoolStorageExtent (Association) Table 16-51 Class: SMX_SASSto
Table 16-53 Class: SMX_SASPrimordialPoolNoRaidStorageExtent (CIM_ConcreteComponent) Property name Property implementation PartComponent SMX_SASStorageExtent SMX_SASStorageSpecificCollectionArraySystem (Association) 1-1-56 Table 16-54 Class: SMX_SASStorageSpecificCollectionArraySystem (CIM_MemberOfCollection) Property name Property implementation Collection SMX_SASStorageSpecificCollection Member SMX_SASArraySystem SMX_SASStorageRedundancySetStorageExtent (Association) 1-1-57 Table 16-55 Clas
Table 16-57 Class: SMX_SASSCSIProtocolControllerStorageVolume (CIM_ProtocolControllerForUnit) Property name Property implementation Antecedent SMX_SASSCSIProtocolController Dependent SMX_SASStorageVolume DeviceNumber Device LUN number DeviceAccess 2 (Read Write) SMX_SASFirmwareArraySystem (Association) 1-1-60 Table 16-58 Class: SMX_SASFirmwareArraySystem (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent SMX_SASFirmware Dependent SMX_SASArraySystem ElementSoft
SMX_ SASSmartDrvCarrierAppInstalledFirmwareIdentity (Association) 1-1-63 This class is implemented only when the hardware includes Smart Drive Carrier support. The following table lists the associations implemented for this class.
Table 16-60 Class: SMX_SASDiskPhysicalPackageDiskDrive (CIM_Realizes) 1-1-67 Property name Property implementation Antecedent SMX_SASDiskPhysicalPackage Dependent SMX_SASDiskDrive SMX_SASStoragePoolStorageVolume (Association) Table 16-61 Class: SMX_SASStoragePoolStorageVolume (CIM_AllocatedFromStoragePool) 1-1-68 Property name Property implementation Antecedent SMX_SASStoragePool Dependent SMX_SASStorageVolume SpaceConsumed Bytes consumed by volume SMX_SASPrimordialPoolStoragePool (Associa
Table 16-64 Class: SMX_SASStorageExtentStorageVolume (CIM_BasedOn) 1-1-71 Property name Property implementation Antecedent SMX_SASStorageExtent Dependent SMX_SASStorageVolume SMX_SASDAPortSCSIProtocolEndpoint (Association) Table 16-65 Class: SMX_SASDAPortSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Property implementation Antecedent SMX_SASDAPort Dependent SMX_SASSCSIProtocolEndpoint SMX_SASStorageGroupHostedCollection (Association) 1-1-72 Table 16-66 Class: SMX_SASStora
Table 16-68 Class: SMX_SASPhysicalPackageArraySystemLocation (CIM_PhysicalElementLocation) Property name Property implementation Element SMX_SASPhysicalPackage Physical Location SMX_SASArraySystemLocation SMX_SASDiskPhysicalPackageDiskDriveLocation (Association) 1-1-75 Table 16-69 Class: SMX_SASDiskPhysicalPackageDiskDriveLocation (CIM_PhysicalElementLocation) Property name Property implementation Element SMX_SASDiskPhysicalPackage PhysicalLocation SMX_SASDiskDriveLocation SMX_SASSCSIProtoco
Table 16-71 HP_DeviceIndication: SAS HBA status OK Property name Property implementation Description A SAS/SATA HBA status has changed from non-OK to OK. AlertingManagedElement WBEM Path of controller AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 1 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
Table 16-71 HP_DeviceIndication: SAS HBA status OK Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table 16-72 HP_DeviceIndication: SAS HBA in Error state Property name Property implementation Description A SAS/SATA HBA status has changed to Error. AlertingManagedElement WBEM Path of controller AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 2 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Replace the HBA.
Table 16-72 HP_DeviceIndication: SAS HBA in Error state Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure) the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table 16-73 HP_DeviceIndication: Physical Drive status OK Property name Property implementation Description A physical drive status has changed from non-OK to OK. AlertingManagedElement WBEM Path of disk drive AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 201 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
Table 16-73 HP_DeviceIndication: Physical Drive status OK Property name Property implementation VariableTypes • VariableTypes[0]: 1 (String) • VariableTypes[1]: 4 (uint16) VariableValues • VariableValues[0]: Short Description of failure • VariableValues[1]: HPSA_DiskDrive.DriveInterface In some cases, the property VariableValues can have N/A or “” values.
Table 16-74 HP_DeviceIndication: Physical Drive status ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity Severity For example, 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Error.
Table 16-74 HP_DeviceIndication: Physical Drive status ERROR Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values.
1-2-5 Physical Drive status REBUILDING Table 16-75 HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity Severity For example, 2 (Information) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Rebuilding. Data is now being rebuilt onto this drive from the RAID set.
Table 16-75 HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication Var
Table 16-75 HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation HP_DeviceIndication DeviceModel 1-2-6 Disk Model string Physical Drive status PREDICTIVE FAILURE Table 16-76 HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A physical dri
Table 16-76 HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation OSType • • On ESXi, 39 (VM) • On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: ..
Table 16-76 HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation HWFirmwareVersion Disk firmware version string HWLogicalLocation Disk Location string For example, Bay 3 HWManufacturer Disk Manufacturer string Disk Serial Number HWSerialNumber HP_DeviceIndication DeviceModel Disk Model string Physical Drive status PREDICTIVE FAILURE due to Solid State Drive Wear out 1-2-7 Table 16-77 HP_DeviceIndication: Drive status PREDICTIVE FAILURE due to SSD Wear out P
Table 16-77 HP_DeviceIndication: Drive status PREDICTIVE FAILURE due to SSD Wear out Property name Property implementation Summary Physical drive in predictive failure state due to SSD wear out EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) ProbableCauseDescription Physical Drive Predictive Failure due to Solid state wear out ProviderVersion Provider version generating the indication in the format, ...
Table 16-77 HP_DeviceIndication: Drive status PREDICTIVE FAILURE due to SSD Wear out Property name Property implementation RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Na
Table 16-78 HP_DeviceIndication: Logical Drive status OK Property name Property implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
Table 16-78 HP_DeviceIndication: Logical Drive status OK 1-2-9 Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing
Table 16-79 HP_DeviceIndication: Logical Drive status ERROR Property name Property implementation ProbableCause 86 (Disk Failure) ProbableCauseDescription Logical Drive Status Changed to Error ProviderVersion Provider version generating the indication in the format, ...
Table 16-79 HP_DeviceIndication: Logical Drive status ERROR 1-2-10 Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Table 16-80 HP_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
Enclosure Power Supply status changed to Non Redundant 1-2-11 Table 16-81 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Subsystem status has changed to non-redundant.
Table 16-81 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation OSVersion The operating system version of the computer system generating the indication in the following format: ..
Table 16-81 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation HP_DeviceIndication DeviceModel Enclosure Model string Enclosure Power Supply Status changed to OK (Redundant) 1-2-12 Table 16-82 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime T
Table 16-82 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation OSType • • On ESXi, 39(VM) • On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: ..
Table 16-82 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string Enclosure Power Supply Status changed to Redundant Degraded 1-2-13 Table 16-83 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation CIM_Indica
Table 16-83 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation ProbableCauseDescription Redundant Power Supply Degraded ProviderVersion Provider version generating the indication in the format, ...
Table 16-83 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Table 16-84 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation EventCategory 24 (Primary Storage Cooling) ProbableCause 1 (Other) ProbableCauseDescription Temperature Status Changed to OK NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType • • On ESXi, 39(VM) • On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the ind
Table 16-84 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product envir
Table 16-85 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.
Table 16-85 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table 16-86 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation Description A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs.
Table 16-86 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values.
Table 16-87 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status has changed from a non-OK state to OK.
Table 16-87 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values
Table 16-88 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there might be a problem with one or more of the fans.
Table 16-88 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indicat
1-2-19 Enclosure Fan Status change to Failure Table 16-89 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan Status changed to Failure.
Table 16-89 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation OSVersion The operating system version of the computer system generating the indication in the format: ..
Table 16-89 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation HP_DeviceIndication DeviceModel Enclosure Model string
1 HP Insight Manager WBEM Smart Component Installer Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Smart Component Installer implements and extends CIM classes described in this document to support installation of HP SmartComponents. This provider supports the InstallFromURI() method with the http URI scheme to retrieve and install HP Smart Components. Profile Name Organization Version DMTF Software Update Profile (DSP 1025) DMTF 1.0.
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
Property Name Property Implementation Description “HP Smart Component Installer” ElementName “HP Smart Component Installer” CIM_ManagedSystemElement Status Same as OperationalStatus[0].
1-2-1-1 Implemented Methods for SMX_SCInstallationService Class Method Name Method Implementation Must be root to request this method. Unless specified, the matching value in the InstallOptionValues[]for each InstallOptions[] is NULL or an empty string. Must set either install or discovery option.
used to track the status of the Job and retrieve detailed status and discovery results. Return Values: 0 : Successful 1 : Not Supported 4 : Failed 6: Target In Use – an Smart Component execution is already in progress 4096: Request initiated, Job Created 1-2-2 SMX_SCInstallationServiceCapabilities Class The SMX_SCInstallationServiceCapabilities class implements the HP_SoftwareInstallationServiceCapabilities class to model the installation service capabilities.
Property Name Property Implementation SupportedExtendedResourceTypes 12: HP Smart Component CanAddToCollection False 2: Defer Reset –Smart Component not setting reboot 3: Force Install – Smart Component force 4: Install – Smart Component default execution 6: Repair – Smart Component –e or rewrite. This value instructs the firmware to be re-installed if the version of firmware to be deployed is the same as or newer than what is already installed.
Property Name Property Implementation cause data corruption and/or data loss. 32773: Smart Component estimated execution time. SupportedURISchemes[] 5: http SMX_SCInstallationServiceCapabilities 1-2-3 SMX_SCInstallerHostedService Class The SMX_SCInstallerHostedService class implements the CIM_HostedService class and associates instances of SMX_ComputerSystem and SMX_SCInstallationService. There is only one instance of SMX_SCInstallerHostedService instantiated on a server.
Property Name Property Implementation Capability References SMX_SCInstallationServiceCapabilities ManagedElement References SMX_SCInstallationService 2: Default Characteristics[] 3: Current SMX_SCInstallerElementCapabilities 1-2-5 SMX_SCInstallerConcreteJob Class The SMX_SCInstallerConcreteJob class implements the HP_InstallerConcreteJob class to model an execution of the Smart Component installation service.
Property Name Property Implementation executed CIM_ManagedSystemElement CIM_LogicalElement Status Same as OperationalStatus[0]. OperationalStatus 2 (OK) StatusDescriptions StatusDescriptions[0] will contain OK CIM_Job PercentComplete 0-100 – proper calculation of percent complete requires client to use the SmartComponent estimated execution time install option. DeleteOnCompletion True StartTime The time the job started.
Property Name Property Implementation CIM_ConcreteJob State of the Job.
1 : Not Supported 4 : Failed Get the discovery data from the last execution of the Smart Component. Method parameters: DiscoveryData[]: array of strings containing the contents of the discovery output file from the SmartComponent GetDiscoveryData Return Values: 0 : Successful 1 : Not Supported 4 : Failed Request to abort or kill the active SmartComponent installation. Only valid if the download is in progress, not the actual execution of the SmartComponent.
1-2-6 SMX_SCInstallerOwningJobElement Class The SMX_SCInstallerOwningJobElement class implements the CIM_OwningJobElement class and associates instances of SMX_SCInstallerConcreteJob and SMX_SCInstallationService. The following table lists the properties implemented.
1 HP Insight Management WBEM System Temperature Sensor Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Management System Temperature Sensor provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Sensor Profile HP WBEM TC 1.2.
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace. Schema Supported by the Provider This provider supports the following classes: • SMX_NumericSensor • SMX_SensorCollection • SMX_SystemSensor • SMX_HostedSensorCollection • SMX_MemberOfSensorCollection The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation NumericSensorType.StatusDescription” Where: ” is the name displayed by the MP or iLO represents the number of the temperature sensor instance, NumericSensorType represents the value of NumericSensorTypeand StatusDescription represents the value of StatusDescriptions[0]. “Temperature Sensor ” ElementName Where: is the name displayed by the MP or iLO.
Property Name Name Property Implementation Temperature Sensor n where n represents the number of the temperature sensor instance(s). CIM_LogicalDevice CreationClassName SMX_NumericSensor DeviceID Unique identifier for this temperature sensor instance. SystemCreationClassName HP_ComputerSystem.CreationClassName SystemName HP_ComputerSystem.
Property Name Property Implementation RateUnits 0 (None) UnitModifier 0 SupportedThresholds[0] = 1 (UpperThresholdNotCritical) if the system will set fans to full speed if the threshold is crossed; SupportedThresholds[0] = 3 (UpperThresholdCritical) set if SupportedThresholds the system will gracefully attempt to shutdown the system if the threshold is crossed; SupportedThresholds[0] = 5 (UpperThresholdFatal) if the system will immediately power down the system if the threshold is crossed.
Property Name Property Implementation CIM_ManagedElement Caption Temperature Sensor Collection This is a collection of temperature sensors. GroupStatusDescription. Description Where: GroupStatusDescription represents the value of the GroupStatusDescriptions[0] property. ElementName Temperature Sensor Collection CIM_SystemSpecificCollection Unique identifier for this sensor collection instance.
1-2-3 SMX_MemberOfSensorCollection Class The SMX_MemberOfSensorCollection class implements the HP_MemberOfSensorCollection class and is used to represent an association between the SMX_NumericSensor and SMX_SensorCollection classes. The following table lists the properties implemented.
1-3 Provider Indications Indications Generated by the Provider The following tables describe the SMX WBEM System Temperature Sensor Provider indications that are implemented for HP ProLiant server platforms where available. HP_AlertIndication: Temperature Sensor Threshold Exceeded 1-3-1 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication. PerceivedSeverity 5 (Major) IndicationTime Time of indication.
Property Name Property Implementation internal/external airflow. Add or repair fans and air baffling if necessary. SystemName HP_ComputerSystem.Name SystemCreationClassName HP_ComputerSystem.CreationClassName HP_AlertIndication Summary Temperature threshold exceeded detected EventCategory 23 (System Cooling) ProbableCause 51 (Temperature Unacceptable) ProbableCauseDescription Temperature Threshold Exceeded Detected ProviderVersion For example: 2.2.0.
Property Name Property Implementation aggregate product environment in the format v..
Property Name Property Implementation Conditional property containing the virtual system UUID when running in a Virtual Connect environment. SystemVirtualUUID HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded 1-3-2 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication. PerceivedSeverity 2 (Information) IndicationTime Time of indication.
Property Name Property Implementation RecommendedActions No action is recommended. SystemName HP_ComputerSystem.Name SystemCreationClassName HP_ComputerSystem.CreationClassName HP_AlertIndication Summary Threshold exceeded condition recovery EventCategory 23 (System Cooling) ProbableCause 52 (Threshold Crossed) ProbableCauseDescription Threshold Exceeded Condition has Recovered ProviderVersion For example: 2.2.0.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties indicated with (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name, if one exists. RackUID * Rack Unique Identifier, if one exists.
1 HP Insight Management WBEM Smart Array Provider The HP Insight Management Web-Based Enterprise Management (WBEM) Management Smart Array provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider only supports internal storage and direct attached external storage, such as MSA 60/70.
Provider Insight Management WBEM support. 1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
Schema Supported by the Provider This provider supports the following classes: • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • SMX_SAArraySystem SMX_SAArrayController SMX_SAStorageVolume SMX_SADiskDrive SMX_SAStorageExtent SMX_SADiskDriveFirmware SMX_SAPhysicalPackage SMX_SAArrayControllerPhysicalPackage SMX_SADiskPhysicalPackage SMX_SAStorageEnclosure SMX_SAStorageEnclosureProcessor SMX_SAPortController SMX_SADAPort SMX_SAFirmware SMX_SAEnclosureFirmware SMX_SAPrimordialPool
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • SMX_SAArraySystemRedundancySet (Association) SMX_SAStorageVolumeStorageSetting (Association) SMX_SAPrimordialPoolStorageCapabilities (Association) SMX_SAStoragePoolStorageCapabilities (Association) SMX_SAArraySystemStorageEnclosureProcessor (Association) SMX_SAArraySystemSCSIProtocolController (Association) SMX_SAArraySystemPortController (Association) SMX_SAArraySystemDiskDrive (Association) SMX_SAArraySystemStorageV
• • • • • • • • • • • • • • • • • • SMX_SADiskPhysicalPackageDiskDriveLocation (Association) SMX_SASCSIProtocolEndpointSCSIProtocolController (Association) SMX_SAStorageEnclosureEnclosureLocation (Association) SMX_SATSASSCSIProtocolEndpoint SMX_SAISASSCSIProtocolEndpoint SMX_SATSASPort SMX_SAISASPort SMX_SAISASPortISASSCSIProtocolEndPoint (Association) SMX_SAArraySystemISASSCSIProtocolEndPoint (Association) SMX_SAArraySystemISASPort (Association) SMX_SAPortControllerISASPort (Association) SMX_SAArraySystem
Property Name Property Implementation Controller/Storage System name and . Refer to “Physical Location” for more information. ElementName For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller. CIM_ManagedSystemElement Overall status of the Array System and attached devices. This is calculated per the algorithm described in the HP Smart Array Profile.
Property Name Property Implementation Array status is unknown CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName SMX_SAArraySystem Controller Serial Number EMBEDDED- will be reported if there is no Serial Number for device is local Name For example: embedded on motherboard.
Property Name Property Implementation CIM_ComputerSystem Dedicated[0]: 3 (Storage) Dedicated Dedicated[1]: 15 (Block Server) IdentifyingDescriptions Other Vendor Specific Name Controller Serial Number EMBEDDED- will be reported if there is no Serial Number for device is local OtherIdentifyingInfo For example: embedded on motherboard. PCISLOT- will be reported if there is no Serial Number for device is local. For example: a PCI occupies slot.
Property Name Property Implementation Controller name and . Refer to “Physical Location” for more information. ElementName For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller. CIM_ManagedSystemElement Status for Array Controller.
Property Name Property Implementation Number and the controller is in a PCI slot Where: is the number of PCI slot.
Property Name Property Implementation CacheStatus See HP Smart Array Profile CacheWritePercent See HP Smart Array Profile ControllerStatus See HP Smart Array Profile ExpandPriority See HP Smart Array Profile NumberOfPorts See HP Smart Array Profile RebuildPriority See HP Smart Array Profile NumberOfInternalPorts See HP Smart Array Profile NumberofExternalPorts See HP Smart Array Profile IsSplitCacheSupported See HP Smart Array Profile SplitReadSize See HP Smart Array Profile SplitWrite
Property Name Property Implementation CIM_ManagedElement Logical drive number with raid Description ElementName For example: Logical Volume 1 (RAID 1+0) CIM_ManagedSystemElement Name VPD Pg83 identifier for the volume.
Property Name DeltaReservation Property Implementation 0 This will indicate extended status for the volume. ExtentStatus[0] 2 (None) 11 (Rebuild – Volume is currently rebuilding data) IsBasedOnUnderlyingRedundancy False True – RAID 1 or above NoSinglePointOfFailure False – RAID 0 NumberOfBlocks Total Number of blocks on the volume.
Property Name Property Implementation StripeSize See HP Smart Array Profile Identify() See HP Smart Array Profile See HP Smart Array Profile LogicalVolumeType See HP Smart Array Profile RelatedLUN See HP Smart Array Profile CacheVolumeCacheState 1-2-4 SMX_SADiskDrive Class The SMX_SADiskDrive class implements the HPSA_DiskDrive class and represents the hard drives connected to Smart Array controllers. The following table lists the properties implemented.
Property Name Property Implementation CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SADiskDrive DeviceID Opaque value SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.
Property Name Property Implementation NegotiatedDataWidth See HP Smart Array Profile NegotiatedSpeed See HP Smart Array Profile Identify() See HP Smart Array Profile SSDTotalPowerOnHours See HP Smart Array Profile SSDPercentageEnduranceUsed See HP Smart Array Profile SSDLifeRemaining See HP Smart Array Profile SSDWearStatus See HP Smart Array Profile SmartDriveCarrierAuthStatus See HP Smart Array Profile OtherSmartDriveCarrierAuthStatus See HP Smart Array Profile 1-2-5 SMX_SAStorageExte
Property Name Property Implementation Operational Status for the disk drive 0 (Unknown) OperationalStatus[0] 2 (OK) 5 (Predictive Failure) 6 (Error) OperationalStatus[1] Drive extended status per HP Smart Array Profile CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SAStorageExtent DeviceID Opaque ID SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAA
Property Name Property Implementation This will indicate extended status for the disk drive Possible values: ExtentStatus[0] 2 (None) 11 (Rebuild – disk drive is currently rebuilding data) NumberOfBlocks Total number of blocks on disk drive Primordial Set to True TotalPowerOnHours Total service hours reported disk drive HPSA_StorageExtent 1-2-6 SMX_SADiskDriveFirmware Class The SMX_SADiskDriveFirmware class implements the HPSA_DiskDriveFirmware class and represents the firmware installed on a disk
Property Name Property Implementation CIM_SoftwareIdentity ClassificationDescriptions[0] Disk Drive Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Disk drive vendor string [0]CIM:SoftwareFamily IdentityInfoType [1]HPQ:SoftwareCategory [0]HPQ: IdentityInfoValue [1]Storage Device VersionString Drive firmware as reported from SCSI identify command HPSA_DiskDriveFirmware 1-2-7 SMX_SAPhysicalPackage Class The SMX_SAPhysicalPackage class implements the H
CIM_ManagedSystemElement See Serial number implementation Name CIM_PhysicalElement CreationClassName SMX_SAPhysicalPackage Manufacturer Controller vendor string Model Controller model string PartNumber N/A – Not Available for this implementation SerialNumber Controller Serial number for HBA’s Tag Opaque Key Version N/A – Not Available for this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) HPSA_PhysicalPackage 1-2-8 SMX_SAArrayControllerPhysicalPackage Class The
Controller name and . Refer to “Physical Location” for more information. ElementName For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller.
The following table lists the properties implemented.
Property Name Property Implementation 3 (Removable when off) 4 (Removable when on or off) HPSA_ DiskPhysicalPackage 1-2-10 SMX_SAStorageEnclosure Class The SMX_SAStorageEnclosure class implements the HPSA_StorageEnclosureclass and represents the physical chassis for an internal or externally attached enclosure.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Port: Box: ElementName Where: is the port and is the box number. CIM_ManagedSystemElement Port: Box: Name Where: is the port and is the box number.
Property Name Property Implementation N/A – Not Available in this implementation Version CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) CIM_PhysicalFrame CIM_Chassis HP_StorageEnclosure See HP Storage Enclosure Profile Location HPSA_StorageEnclosure 1-2-11 SMX_SAStorageEnclosureProcessor Class The SMX_SAStorageEnclosureProcessor class represents the management processor within a Storage Enclosure.
Property Name Property Implementation Operational status for enclosure and associated power supplies, fans and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile. Index values are populated as follows.
Property Name Property Implementation Name Opaque Key NameFormat Other CIM_ComputerSystem Dedicated[0] 2 (Other) IdentifyingDescriptions[0] Other Vendor Specific Name OtherDedicatedDescriptions[0] SDE - indicates Storage Device Enclosure Port Number:BoxNumber enclosure is attached to. OtherIdentifyingInfo[0] For example: 1E:1 HPSA_StorageEnclosureProcessor 1-2-12 SMX_SAPortController Class The SMX_SAPortController class represents the HBA in the host system. There is one instance per HBA.
Property Name Property Implementation CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SAPortController DeviceID Controller serial number SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.
Property Name Property Implementation CIM_ManagedElement Controller name and . Refer to “Physical Location” for more information. ElementName For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller.
Property Name SystemName Property Implementation SMX_SAArraySystem.Name CIM_LogicalPort UsageRestriction 2 (Front-End Only) CIM_DAPort HPSA_DAPort 1-2-14 SMX_SAFirmware Class The SMX_SAFirmware class implements the HPSA_Firmware class and represents the firmware installed on a Smart Array controller. The following table lists the properties implemented.
Property Name Property Implementation InstanceID Opaque key Manufacturer Controller Vendor string [0]CIM:SoftwareFamily IdentityInfoType [1]HPQ:SoftwareCategory [0]HPQ: IdentityInfoValue [1]Storage Controller VersionString Controller firmware version string TargetTypes Controller Model HPSA_Firmware 1-2-15 SMX_SASmartDriveCarrierAppFirmware Class The SMX_SASmartDriveCarrierAppFirmware class implements the CIM_SoftwareIdentity class and represents the firmware installed on a S
Property Name Description Property Implementation Smart Drive Carrier Application Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Smart Drive Carrier Application Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Controller Vendor string [0]CIM:SoftwareFamily IdentityInfoType [1]HPQ:SoftwareCategory [0]HPQ: IdentityInfoValue [1]Storage Device VersionString Controller firmware version string SMX_SASmartDriveCarrierAppFirmware 1-2-16 SMX_ SAS
Property Name Name Property Implementation Smart Drive Carrier Bootloader Firmware CIM_LogicalElement Caption Smart Drive Carrier Bootloader Firmware Description Smart Drive Carrier Bootloader Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Smart Drive Carrier Bootloader Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Controller Vendor string [0]CIM:SoftwareFamily IdentityInfoType [1]HPQ:SoftwareCategory [0]HPQ: IdentityInfoValue [1]Sto
Property Name Property Implementation CIM_LogicalElement Caption License Key value Description “The license details of Smart Array Controller” CIM_SoftwareIdentity InstanceID Opaque key SMX_ SALicense Name License Key value VersionString License Key Version OperationalStatus Status of License key.
Property Name Property Implementation 5 – Site License 1-2-18 SMX_SAEnclosureFirmware Class The SMX_SAEnclosureFirmware class implements the HPSA_EnclosureFirmware class and represents the firmware installed on a Smart Array Enclosure. The following table lists the properties implemented.
Property Name Property Implementation [1]HPQ:SoftwareCategory [0]HPQ: IdentityInfoValue [1]StorageDevice VersionString Enclosure firmware string TargetTypes Enclosure model HPSA_EnclosureFirmware 1-2-19 SMX_SAPrimordialPool Class The SMX_SAPrimordialPool class implements the HPSA_PrimordialPool class and represents the total raw storage managed by the array controller. There is one instance per array system. The following table lists the properties implemented.
Property Name Property Implementation InstanceID Opaque key PoolID Controller serial number Primordial Always set to TRUE RemainingManagedSpace Remaining raw space on controller. This is calculated by summing the remaining space on all drives attached to the controller. TotalManagedSpace Total raw space available to controller. This is calculated by summing the total space on all drives connected to this controller.
Property Name Property Implementation CIM_StoragePool InstanceID Opaque key Controller serial number: where n is the array number PoolID as supplied from API.
Property Name Property Implementation BadTargetErrors See HP Smart Array Profile DRQTimeouts See HP Smart Array Profile ECCRecoveredReadErrors See HP Smart Array Profile Disk location ElementName For example: Port: 1E Box 1 Bay: 5 FailedReadRecovers See HP Smart Array Profile FailedWriteRecovers See HP Smart Array Profile FormatErrors See HP Smart Array Profile HardReadErrors See HP Smart Array Profile HardwareErrors See HP Smart Array Profile HardWriteErrors See HP Smart Array Profile
Property Name Property Implementation SeekErrors See HP Smart Array Profile ServiceHours See HP Smart Array Profile SpinUpErrors See HP Smart Array Profile RetryRecoveredReadErrors See HP Smart Array Profile RetryRecoveredWriteErrors See HP Smart Array Profile 1-2-22 SMX_SAStorageSetting Class The SMX_SAStorageSetting class implements the HPSA_StorageSetting class and represents the current raid configuration for a storage volume. There is one instance per storage volume.
Property Name ChangeableType Property Implementation 0 (Not Changeable) 1 (RAID 0, RAID 4, RAID 5, RAID 6, RAID 50, RAID 60) DataRedundancyGoal 2 (RAID 1, RAID 1+0, RAID 5+1) 1 (RAID 0, RAID 4, RAID 5, RAID 6, RAID 50, RAID 60) DataRedundancyMax 2 (RAID 1, RAID 1+0, RAID 5+1) 1 (RAID 0, RAID 4, RAID 5, RAID 6, RAID 50, RAID 60) DataRedundancyMin 2 (RAID 1, RAID 1+0, RAID 5+1) DeltaReservationGoal 0 DeltaReservationMax 0 DeltaReservationMin 0 False – RAID 0 NoSinglePointOfFailure True – RAID 1+0, RAI
Property Name Property Implementation HPSA_StorageSetting 1-2-23 SMX_SADriveCage Class The SMX_SADriveCage class implements the HPSA_DriveCage class and represents the drive cage assembly and back plane within a storage enclosure. There may be multiple instances within a duplexed enclosure.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Port ElementName Where: is the name of the port this drive cage is connected.
Property Name Property Implementation DriveBays See HP Smart Array profile DuplexLocation See HP Smart Array profile HPSA_DriveCage 1-2-24 SMX_SASCSIProtocolEndpoint Class The SMX_SASCSIProtocolEndpoint class implements the HPSA_SCSIProtocolEndpoint class and represents an access point to storage resources. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Controller name and .
Property Name Property Implementation CreationClassName SMX_SASCSIProtocolEndpoint Name HBA Serial Number SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.
Property Name Property Implementation CIM_ManagedElement Controller name and . Refer to “Physical Location” for more information. ElementName For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller.
Property Name SystemName Property Implementation SMX_SAArraySystem.Name CIM_ProtocolController MaxUnitsControlled 32 CIM_ SCSIProtocolController HPSA_ SCSIProtocolController 1-2-26 SMX_SAStorageRedundancySet Class The SMX_SAStorageRedundancySet class implements the HPSA_StorageRedundancySet class and represents disk sparing aspect of a RAID configuration. There is an instance for every logical drive that has spare drives configured. The following table lists the properties implemented.
Property Name Property Implementation 2 (Fully Redundant) RedundancyStatus 4 (Redundancy Lost) 5 (Limited Sparing) TypeOfSet[0] CIM_StorageRedundancySet HPSA_StorageRedundancySet 1-2-27 SMX_SAStorageSpecificCollection Class The SMX_SAStorageSpecificCollection class implements the HPSA_StorageSpecificCollection class and represents a collection of smart array controllers that have been grouped together to report consolidated status. The following table lists the properties implemented.
Property Name Property Implementation how this is calculated and status example. GroupStatusDescriptions[0] Description of GroupOperationStatus HPSA_ StorageSpecificCollection 1-2-28 SMX_SADriveCageLocation Class The SMX_SADriveCageLocation class implements the HPSA_DriveCageLocation class and represents a location string for the drive cage. The following table lists the properties implemented.
Property Name Property Implementation HBA Port identifier For example: J3 LocationInformation[0] For example: 2I For example: 1E LocationInfoDesc[0] Port HPSA_DriveCageLocation 1-2-29 SMX_SAArraySystemLocation Class The SMX_SAArraySystemLocation class implements the HPSA_ArraySystemLocation class and represents a location string for the array system. The following table lists the properties implemented.
Property Name Property Implementation ElementLocationTag PCI Slot Number – when ‘Adapter’ is specified in ElementLocationTagDesc 23 (Adapter) – for internal HBA’s ElementLocationTagDesc Array of text values representing the location components that describe this Ethernet Controller Physical location. LocationInformation[0] LocationInfoDesc[0] per LocationInfornation[0]. Refer to the LocationInfoDescription array to determine what type of location information is represented.
Property Name Property Implementation Controller name, Drive Type and Disk Location ElementName For example: Smart Array E500 Physical Drive - Port: 1E Box 1 Bay: 5 CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag Bay Number of Disk Drive - When ‘Bay’ is specified in ElementLocationTagDesc.
Property Name Property Implementation CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location For Internal HBA’s: PCI Slot Number ElementLocationTag For example: 3 – for adapter in PCI Slot 3 For example: 0 – for Embedded adapter ElementLocationTagDesc 23 (Adapter) – for Internal HBA’s Array of text values representing the location components that describe this Ethernet Controller Physical location. LocationInformation[0] LocationInfoDesc[0] per LocationInfornation[0].
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement For Primodial Pools: Controller name and . Refer to “Physical Location” for more information. For example: “Smart Array in Slot=3” for internal ElementName For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller.
Property Name Property Implementation DeltaReservationMax 0 DeltaReservationMin 0 ElementType 5 (Storage Pool) True - When number of drives > 1 (For example: Pool can be configured for redundancy) NoSinglePointOfFailure False – When number of drives <= 1 True - When number of drives > 1 NoSinglePointOfFailureDefault (For example: Pool can be configured for redundancy) False – When number of drives <= 1 0 (When number of drives <= 1) PackageRedundancyDefault 1 (When number of drives = 2 or 3) 2
Property Name Property Implementation CIM_ManagedElement Controller name and . Refer to “Physical Location” for more information. ElementName For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller. CIM_Product IdentifyingNumber Opaque key Name String representing the Marketing name. Vendor HP Version Firmware version of HBA or Storage System.
Property Name Property Implementation Enclosure location Caption Port: Box: Where: is the port and is the box number. Enclosure location Description Port: Box: Where: is the port and is the box number.
1-2-36 SMX_SAPrimordialPoolStorageCapabilities (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Capabilities SMX_SAStorageCapabilities ManagedElement SMX_SAPrimordialPool 1-2-37 SMX_SAStoragePoolStorageCapabilities (Association) The following table lists the associations implemented for this class.
GroupComponent SMX_SAArraySystem PartComponent SMX_SASCSIProtocolController 1-2-40 SMX_SAArraySystemPortController (Association) The following table lists the associations implemented for this class. Property Name Property Implementation SameElement SMX_SAArraySystem SystemElement SMX_SAPortController 1-2-41 SMX_SAArraySystemDiskDrive (Association) The following table lists the associations implemented for this class.
Property Name Property Implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SAStorageExtent 1-2-44 SMX_SAArraySystemDAPort (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SADAPort 1-2-45 SMX_SAArraySystemPrimordialPool (Association) The following table lists the associations implemented for this class.
1-2-47 SMX_SAComputerSystemArraySystem (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent HP_ComputerSystem PartComponent SMX_SAArraySystem 1-2-48 SMX_SAArraySystemArrayController (Association) The following table lists the associations implemented for this class.
GroupComponent SMX_SAProduct PartComponent SMX_SAPhysicalPackage 1-2-51 SMX_SAStorageEnclosureDriveCage (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAStorageEnclosure PartComponent SMX_SADriveCage SMX_SAPhysicalPackageArrayControllerPhysicalPackage (Association) 1-2-52 The following table lists the associations implemented for this class.
1-2-54 SMX_SADriveCageDiskPhysicalPackage (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SADriveCage PartComponent SMX_SADiskPhysicalPackage 1-2-55 SMX_SAStoragePoolStorageExtent (Association) The following table lists the associations implemented for this class.
Property Name Property Implementation Collection SMX_SAStorageRedundancySet Member SMX_SAStorageExtent 1-2-58 SMX_SAArraySystemFirmware (Association) The following table lists the associations implemented for this class. Property Name Property Implementation InstalledSoftware SMX_SAFirmware System SMX_SAArraySystem SMX_SASCSIProtocolControllerStorageVolume (Association) 1-2-59 The following table lists the associations implemented for this class.
Antecedent SMX_SAFirmware Dependent SMX_SAArraySystem ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus ElementSoftwareStatus[1]: 6 (Installed) SMX_SAStorageEnclosureProcessorEnclosureFirmware (Association) 1-2-61 The following table lists the associations implemented for this class.
ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus ElementSoftwareStatus[1]: 6 (Installed) 1-2-63 SMX_SAArrayControllerLicense (Association) This class is implemented only when the hardware includes License support. The following table lists the associations implemented for this class.
The following table lists the associations implemented for this class. Property Name Property Implementation System HPSA_ArraySystem InstalledSoftware HPSA_SmartDriveCarrierAppFirmware SMX_ SASmartDrvCarrierBootldrElementFirmwareIdentity (Association) 1-2-66 This class is implemented only when the hardware includes Smart Drive Carrier support. The following table lists the associations implemented for this class.
1-2-68 SMX_SADiskDriveStorageExtent (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SADiskDrive Dependent SMX_SAStorageExtent 1-2-69 SMX_SADiskPhysicalPackageDiskDrive (Association) The following table lists the associations implemented for this class.
Antecedent SMX_SAPrimordialPool Dependent SMX_SAStoragePool SpaceConsumed Bytes consumed by storage pool 1-2-72 SMX_SASpareExtentStorageExtent (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SAStorageExtent Dependent SMX_SAStorageExtent 1-2-73 SMX_SASpareExtentStorageRedundancySet (Association) The following table lists the associations implemented for this class.
1-2-75 SMX_SADAPortSCSIProtocolEndpoint (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SADAPort Dependent SMX_SASCSIProtocolEndpoint 1-2-76 SMX_SAStorageGroupHostedCollection (Association) The following table lists the associations implemented for this class.
Property Name Property Implementation Antecedent SMX_SAArrayControllerPhysicalPackage Dependent SMX_SAArrayController 1-2-79 SMX_SADiskDriveMediaAccessStatData (Association) The following table lists the associations implemented for this class.
1-2-82 SMX_SADriveCageDriveCageLocation (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Element SMX_SADriveCage PhysicalLocation SMX_SADriveCageLocation SMX_SADiskPhysicalPackageDiskDriveLocation (Association) 1-2-83 The following table lists the associations implemented for this class.
Property Name Property Implementation Element SMX_SAStorageEnclosure PhysicalLocation SMX_SAStorageEnclosureLocation 1-2-86 SMX_SATSASSCSIProtocolEndpoint SMX_SATSASSCSIProtocolEndpoint implements the HPSA_SATSASSCSIProtocolEndPoint class and represents each port on SAS Drive. The following table lists the associations implemented for this class.
Property Name Property Implementation SystemCreationClassName SMX ArraySystem SystemName The property value of HPSA_ArraySystem.
Property Name Property Implementation CIM_ManagedElement Protocol Endpoint for Where: is the value populated in the ElementName property of the instance of SMX_SATSASPort associated to this instance via the association SMX_SATSASPortTSASSCSIPE Caption Protocol Endpoint for ElementName Where: is the value populated in the ElementName property of the instance of SMX_SATSASPort associated to this instance via the association SMX_SATSASPortTSASSCSIPE CIM_ManagedSystemElement The sa
Property Name Property Implementation CIM_ManagedElement Port Caption Where: is a unique index across all ports on a single drive Port ElementName Where: is a unique index across all ports on a single drive CIM_ManagedSystemElement 2 (OK) OperationalStatus For multi-path supported firmware implementations, the status of the port is OK, and the status of the path is the only element that can be detected.
Property Name Property Implementation CIM_LogicalPort UsageRestriction 4 (Not restricted) PortType 94 (SAS) CIM_SASPort PermanentAddress 1-2-89 Not supported SMX_SAISASPort The following table lists the associations implemented for this class.
Property Name Property Implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) RequestedState 12 (Not Applicable) CIM_LogicalDevice SystemnCreationClassName SMX ArraySystem SystemName The property value of HPSA_ArraySystem.name CreationClassName SMX_SAISASPort SMX SAPortController.DeviceIDport # DeviceID Where: SMX_SAPortController.
1-2-90 SMX_SAISASPortISASSCSIProtocolEndpoint (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SAISASPort Dependent SMX_SAISASSCSIProtocolEndpoint SMX_SAArraySystemISASSCSIProtocolEndPoint (Association) 1-2-91 The following table lists the associations implemented for this class.
Antecedent SMX_SAPortController Dependent SMX_SAISASPort SMX_SAArraySystemTSASSCSIProtocolEndpoint (Association) 1-2-94 The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SAArraySystem Dependent SMX_SATSASSCSIProtocolEndpoint 1-2-95 SMX_SATSASPortTSASSCSIProtocolEndpoint (Association) The following table lists the associations implemented for this class.
SMX_SADiskDriveTSASSCSIProtocolEndpoint (Association) 1-2-97 The following table lists the associations implemented for this class. Property Name Property Implementation AvailableSAP SMX_SATSASSCSIProtocolEndpoint ManagedElement SMX_SADiskDrive 1-2-98 SMX_SASCSIInitiatorTargetLogicalUnitPath The following table lists the associations implemented for this class.
SameElement 1-2-100 SMX_SAPortController SMX_ SACacheVolumeStorageVolume (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SAStorageVolume Dependent SMX_SAStorageVolume 1-3 Provider Indications Indications Generated by the Provider 1-3-1 The following tables describe the SMX WBEM Smart Array Provider indications that are implemented for HP ProLiant server platforms where available.
Property Name Property Implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 201 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
Property Name Property Implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication SolutionProductModel Conditional property containing the Solution Nam
Property Name Property Implementation running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Physical Disk firmware version string Physical Disk Location string HWLogicalLocation For example: Port:1E Box: 1 Bay 5 HWPhysicalLocation Physical Location of the Failed Drive (Bay Number) HWSerialNumber Physical Disk Serial Number HP_DeviceIndication DeviceModel Physical Disk Model string Controller Location DeviceControllerLogicalLocation For example: SmartArray 642 in Slot
HP_DeviceIndication: Physical Drive Status Changed to ERROR 1-3-2 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication Severity PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Error.
Property Name Property Implementation Summary Physical drive status Error EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) ProbableCauseDescription Physical Drive Status Changed to Error NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation String (1) VariableTypes[] uint16 (4) FailureDescription – short description of the failure VariableValues[] Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription – last failure reason string from the drive. HPSA_DiskDrive.
Property Name Property Implementation AlertingManagedElement WBEM Path of SMX_SADiskDrive class AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 203 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array ( RecommendedActions No action is recommended.
Property Name ProviderVersion Property Implementation For example: 2.2.0.
Property Name Property Implementation Conditional property containing the virtual system UUID when running in a Virtual Connect environment SystemVirtualUUID HP_HardwareIndication HWFirmwareVersion Physical Disk firmware version string Physical Disk Location string HWLogicalLocation For example: Port:1E Box: 1 Bay 5 HWPhysicalLocation Physical Location of the Failed Drive (Bay Number) HWSerialNumber Physical Disk Serial Number FailureDescription VariableNames[] DriveInterface LastFailureDescript
HP_DeviceIndication: Physical Drive Status Changed to PREDICTIVE FAILURE 1-3-4 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Predictive Failure.
Property Name Property Implementation EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) ProbableCauseDescription Physical Drive Status Changed to Predictive Failure. NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation String (1) VariableTypes[] uint16 (4) FailureDescription – short description of the failure VariableValues[] Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription – last failure reason string from the drive. HPSA_DiskDrive.
Property Name Property Implementation AlertingManagedElement WBEM Path of SMX_SADiskDrive class AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 206 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array ( RecommendedActions Replace drive immediately to avoid loss of data.
Property Name Property Implementation .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Property Name Property Implementation Controller Location DeviceControllerLogicalLocation For example: SmartArray 642 in Slot 2 HPSA_StorageVolumeIndication : Logical Drive Status Changed to OK 1-3-6 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A logical drive status has changed from a non-OK state to OK.
Property Name Property Implementation RecommendedActions No action is recommended.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name VariableValues[] Property Implementation FailureDescription short description of the failure HP_DeviceIndication HPSA_StorageVolumeIndication Current OperationalStatus values for Storage Volume DeviceOperationalStatus[0]: SMX_SAStorageVolume.OperationalStatus[0] DeviceOperationalStatus DeviceOperationalStatus[1]: SMX_SAStorageVolume.
Property Name IndicationTime Property Implementation Time of indication CIM_AlertIndication Description A logical drive status has changed to Error. AlertingManagedElement WBEM Path of SMX_SAStorageVolume class AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 102 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check for failed or removed physical drives.
Property Name Property Implementation OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Property Name Property Implementation Previous OperationStatus values for Storage Volume DeviceOperationalStatusPrevious[0]: SMX_SAStorageVolume.OperationalStatus[0] DeviceOperationalStatusPrevious DeviceOperationalStatusPrevious[1]: SMX_SAStorageVolume.
Property Name Property Implementation unknown ProviderName HP Smart Array RecommendedActions Check status of physical drives. Degraded status may be caused by failed or missing physical drives, or a data recovery operation on one or more physical drives.
Property Name Property Implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow a
Property Name Property Implementation Logical drive number & RAID Level. HWLogicalLocation For example: LogicalDrive 1 (RAID 1+0). VariableNames[] FailureDescription VariableTypes[] String (1) VariableValues[] FailureDescription short description of the failure HP_DeviceIndication SMX_SAStorageVolumeIndication Current OperationStatus values for Storage Volume DeviceOperationalStatus[0]: SMX_SAStorageVolume.
1-3-9 HP_DeviceIndication: Controller Status Changed to OK Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller status has changed from nonOK to OK. AlertingManagedElement WBEM Path to SMX_SAArrayController class.
Property Name Property Implementation ProbableCause 1 (Other) ProbableCauseDescription Array Controller Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation RackName * Rack name, if one exists RackUID * Rack Unique Identifier, if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product e
Property Name Property Implementation FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation ProviderName HP Smart Array ( RecommendedActions Check controller status and run diagnostics.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name HWSerialNumber Property Implementation Array Controller Serial Number FailureDescription VariableNames[] CacheSizeTotal CacheSerialNumber String (1) VariableTypes[] uint32 (5) FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation from non-OK to OK. AlertingManagedElement WBEM Path to SMX_SAArrayController class. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 6 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
Property Name Property Implementation ProviderVersion For example: 2.2.0.
Property Name Property Implementation a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string Array Controller Location string HWLogicalLocation For example: Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer HWSerialNumber Array Controller Serial Number FailureDescription VariableNames[] CacheSizeTotal CacheSerialNumber String (1) VariableTypes[] uint32 (5) FailureDescription – short description of the failure Variable
HP_DeviceIndication: Controller Battery Status Changed to not fully charged 1-3-12 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller Battery status has changed to Not Fully Charged. AlertingManagedElement WBEM Path to SMX_SAArrayController class.
Property Name Property Implementation EventCategory 6 (Primary Storage) ProbableCause 99 (low battery) ProbableCauseDescription Controller Battery Status Changed to Not Fully Charged NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation ProviderName HP Smart Array RecommendedActions Check battery connection and replace if necessary.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name HWSerialNumber Property Implementation Array Controller Serial Number FailureDescription VariableNames[] CacheSizeTotal CacheSerialNumber String (1) VariableTypes[] uint32 (5) FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation AlertingManagedElement WBEM Path to SMX_SAArrayController class. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 9 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
Property Name Property Implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication SystemVirtualUUID Conditional property containing the virtual system
Property Name Property Implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller Cache status has changed to Temporarily Disabled. This may be caused by a rebuild or configuration change. Normal operation will return after background operations have completed. AlertingManagedElement WBEM Path to SMX_SAArrayController class.
Property Name Property Implementation ProbableCause 35 (Performance Degraded) ProbableCauseDescription Array Controller Cache Status Changed to Temporarily Disabled NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation RackName * Rack name, if one exists RackUID * Rack Unique Identifier, if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product e
Property Name Property Implementation FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check the cache controller error code and run diagnostics.
Property Name Property Implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.
Property Name Property Implementation Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer HWSerialNumber Array Controller Serial Number FailureDescription VariableNames[] CacheSizeTotal CacheSerialNumber String (1) VariableTypes[] uint32 (5) FailureDescription – short description of the failure VariableValues[] CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name IndicationTime Property Implementation Time of indication CIM_AlertIndication Description A Storage Enclosure Power Subsystem status has changed to non-redundant. AlertingManagedElement WBEM Path of SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 301 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check status of all enclosure power supplies.
Property Name Property Implementation OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Property Name Property Implementation AlertingManagedElement WBEM Path of SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 302 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
Property Name Property Implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication SolutionProductModel Conditional property containing the Solution Nam
Property Name Property Implementation HP_HardwareIndication Enclosure Location string HWLogicalLocation For example: Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string HP_DeviceIndication: Enclosure Power Supply Status changed to Redundant Degraded 1-3-19 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indicati
Property Name Property Implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check status of all enclosure power supplies. Ensure that power supplies have not failed. Add or replace power supplies as necessary.
Property Name Property Implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Property Name Property Implementation Enclosure Location string HWLogicalLocation For example: Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string HP_DeviceIndication: Enclosure Temperature sensor Status changed to OK 1-3-20 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description
Property Name Property Implementation ProviderName HP Smart Array ( RecommendedActions No action is recommended.
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name DeviceModel Property Implementation Enclosure Model string HP_DeviceIndication: Enclosure Temperature sensor Status Changed to Warning 1-3-21 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status changed to Warning Condition.
Property Name Property Implementation SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Temperature sensor status Warning Condition EventCategory 24 (Primary Storage Cooling) ProbableCause 51 (Temperature Unacceptable) ProbableCauseDescription Temperature Status Changed to Warning Condition NetworkAddresses Contains a list of all the IP addresses of the computer
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name DeviceModel Property Implementation Enclosure Model string HP_DeviceIndication: Enclosure Temperature sensor Status Changed to Critical 1-3-22 Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status has changed to Critical.
Property Name Property Implementation SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Temperature sensor status Critical EventCategory 24 (Primary Storage Cooling) ProbableCause 51 (Temperature Unacceptable ) ProbableCauseDescription Temperature Status Changed to Critical NetworkAddresses Contains a list of all the IP addresses of the computer system generatin
Property Name Property Implementation 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems ImpactedDomain Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name DeviceModel 1-3-23 Property Implementation Enclosure Model string HP_DeviceIndication: Enclosure Fan Status Changed to OK Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status has changed from a nonOK state to OK.
Property Name Property Implementation HP_AlertIndication Summary Fan status OK EventCategory 24 (Primary Storage Cooling) ProbableCause 1 (Other) ProbableCauseDescription Fan Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there may a problem with one or more of the fans.
Property Name Property Implementation EventCategory 24 (Primary Storage Cooling) ProbableCause 94 (Fan failure) ProbableCauseDescription Fan Degraded NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation.
Property Name Property Implementation ProbableCauseDescription Fan Failure NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation RackUID * Rack Unique Identifier, if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format
Property Name Property Implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Smart Array View Class Data Sheet 1. Overview The HP Smart Array View Class data sheet describes host based Smart Array HBA’s and the attached devices. Note that current View Class implementation does not support externally attached Smart Array based MSA devices (e.g. MSA500, MSA20). 2. Class Implementations 2.1 HPVC_SAController HPVC_SAController represents the Smart Array HBA. There will be one instance per HBA.
Property Name Property Implementation CIM_ComputerSystem VMware_Controller HPVC_SAController 2.2 HPVC_SAControllerFirmware HPVC_SAControllerFirmware represents Smart Array controller firmware. There will be one instance per HBA. Table 2 – Class: HPVC_SAControllerFirmware Property Name Property Implementation CIM_ManagedElement ElementName Smart Array Controller X Note: VMware Virtual Infrastructure client requires controller name string X matches “vmwControllerX” reported in HPVC_SAControllerName.
Property Name Property Implementation CIM_ LogicalElement CIM_EnabledLogicalElement CIM_LogicalDevice CreationClassName HPVC_SABattery DeviceID Battery on HPSA X SystemCreationClassName SMX_ComputerSystem SystemName Server host name CIM_Battery BatteryStatus 1(Other) 2(Unknown) 3(Fully Charged) 4(Low) 5(Critical) 6(Charging) 7(Charging and High) 8(Charging and Low) 9(Charging and Critical) 10(Undefined) 11(Partially Charged) 12(Learning) 13(Overcharged) VMware_Battery HPVC_SABattery 2.
Property Name Property Implementation CIM_ManagedSystemElement Name Serial number HealthState 0 (Unknown) 5 (OK) 10 (Degraded/Warning) 15 (Minor Failure) 20 (Major Failure) 25 (Critical Failure) 30 (Non-recoverable Error) CIM_LogicalElement Caption Disk Y on HPSA X CIM_EnabledLogicalElement CIM_LogicalDevice CreationClassName HPVC_SAStorageExtent DeviceID HPVC_SAStorageExtent-- e.g.
Property Name ElementName Property Implementation Logical Volume Y on HPSA X : RAID level : Capacity : Associated Physical Disks : Detailed Status Associated Physical Disks reports a list of physical disks that are associated with this logical volume. Physical disk’s index should match the one reported in HPVC_StorageExtentElement Name. Detailed Status shows detailed volume status information when this logical volume is degraded or failed.
1 HP Insight Manager WBEM System Fan Provider Overview The HP Insight Management Web-Based Enterprise Management (WBEM) System Fan provider implements and extends CIM classes described in this document to model the base server. These classes provide computational information and capabilities and serve as an aggregation point to associate one or more elements that make up a base server, such as: Fans, PowerSupplies, Processor and Memory (Volatile and/or NonVolatile Storage).
1-2 Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
Unless otherwise noted, all of the property implementation values given are for HP ProLiant and HP Integrity (cellular and non-cellular) systems. The location related properties and implementation values are determined based on the server type so they may differ. 1-2-1 SMX_Fan Class The SMX_Fan class is used to model fans on servers. Fan numbers for existing instances do not change when other fans are added and removed. The following table lists the properties implemented.
Property Name Property Implementation Description of the status of the fan corresponding to the OperationalStatus.
Property Name Property Implementation CIM_Fan True – if fan supports variable speed VariableSpeed False – if fan does not support variable speed or is unknown HP_Fan FanType Enumeration describing the type of fan. Please refer to the Managed Object Format. CurrentSpeed Speed of the fan in CurrentSpeedUnits CurrentSpeedUnits Enumeration describing the units for CurrentSpeed. Please refer to the Managed Object Format.
Property Name Property Implementation HP_GroupSystemSpecificCollection Represents the most severe cooling redundancy status and non-fault tolerant fan operational status: 0 (Unknown) – if fan collection status is unknown; 2 (OK) – if fans are operating properly; 3 (Degraded) – if no SMX_Fan.OperationalStatus[0] for all non-fault tolerant fans report 6 (Error) and SMX_FanRedundancySet.
CIM_ManagedElement Short description of this redundancy set, for example: Cooling Caption Redundancy Set Where: represents the number of the redundancy set instance. Description of this redundancy set For example: Description Cooling Redundancy Set is collection of fault tolerant fans that provide redundant cooling Where: represents the number of the redundancy set instance. User printable name for this cooling redundancy set.
0 (Unknown) – if the redundancy status is unknown; 2 (Fully Redundant) – if all fans in the set are operating properly and enough to achieve redundancy; 3 (Degraded Redundancy) – if there are at least enough fans for the RedundancyStatus redundancy set to provide cooling, but fans have failed; 4 (Redundancy Lost) – if there are not enough fans required to achieve redundancy, but enough for the redundancy set to provide cooling; 5 (Overall Failure) – if there are not enough fans operating properly for the
SMX_MemberOfFanCollection Class 1-2-6 The SMX_MemberOfFanCollection class is used to represent an association between the HP_Fan and HP_FanCollection classes. The following table lists the properties implemented. Property Name Property Implementation Collection References HP_FanCollection Member References HP_Fan 1-2-7 SMX_HostedFanCollection Class The SMX_HostedFanCollection class is used to represent an association between HP_FanCollection and the computer system that contains this collection.
The following table lists the properties implemented. Property Name Property Implementation GroupComponent References HP_ComputerSystem PartComponent References HP_Fan 1-2-9 SMX_FanLocation Class The SMX_FanLocation class is used to model fan locations on servers. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Short description of this fan location, including the name displayed by the MP or iLO.
Property Name Property Implementation Location string based on ElementLocationTagDesc.
Property Name Property Implementation Description of this fan module, including ElementName, type and status. For example: provides cooling for FanType. Description Where: represents the value of ElementName, FanType represents the corresponding string value of the FanType enumeration and represents the value of StatusDescriptions[0]. Name of this fan from the name displayed by the MP or iLO and location.
Property Name Property Implementation CreationClassName SMX_FanModule Tag Unique identifier for this fan instance. CIM_PhysicalPackage 0 (Unknown) RemovalConditions 3 (Removable when off) 4 (Removable when on or off) PackageType 1-2-12 7 (Fan) SMX_SystemPhysicalFan Class The SMX_SystemPhysicalFan class implements the HP_SystemPhysicalFan class and association the HP_ComputerSystemChassis instance with HP_FanModule. The following table lists the properties implemented.
1-2-14 SMX_FanSlot Class The SMX_FanSlot class is used to model physical fan slots on servers. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Short description of this fan slot, to include the number and location. Caption For example: Fan 1 at CabinetFan=01 Description of the fan slot. Description For example: Fan 1 at CabinetFan=01 Name of the fan slot.
Property Name Property Implementation CIM_PhysicalPackage ConnectorLayout 6 (Slot) Number Where: represents the number of the fan slot. 1-2-15 SMX_SystemFanSlot Class The SMX_SystemFanSlot class implements the HP_FanSlot class and association the HP_ComputerSystemChassis instance with HP_FanSlot. The following table lists the properties implemented.
Property Name Property Implementation CIM_ManagedElement Short description of the fan speed sensor from the name displayed by the MP or iLO and the location. Caption For example: Fan speed sensor for Fan 1 at CabinetFan=01 Description of the fan speed sensor including name displayed by the MP or iLO, the location, and status. Description For example: Fan 1 detects fan speed. Located at CabinetFan=01. Fan speed sensor is operating properly.
Property Name Property Implementation SystemCreationClassName HP_ComputerSystem.CreationClassName SystemName HP_ComputerSystem.
GroupComponent References HP_ComputerSystem PartComponent References SMX_FanSpeedSensor 1-2-19 SMX_AssociatedFanSensor SMX_AssociatedFanSensor is used to represent an association between HP_Fan and the SMX_FanSpeedSensor that is reporting the speed of the fan.
Property Name Property Implementation Provider Version in the format VV.UU.FF. ProviderVersion NetworkAddresses For example: 01.05.00 Contains a list of all the IP addresses of the computer system generating the indication. On ESX, 39 (VM) OSType On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: major.minor.build SystemFirmwareVersion Array of firmware versions of the computer system generating the indication.
Property Name Property Implementation BladeName HP_ComputerSystem.Name BladeBay HP_BladeCSLocation.LocationInformation[0] The following indications are implemented for Proliant server platforms where available. System Fan indications are described below. 1-3-2 HP_DeviceIndication: Fan Removed Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication A fan has been removed Description Where: is the fan number that was removed.
Property Name Property Implementation EventCategory 23 (System Cooling) ProbableCause 1 (Other) ProbableCauseDescription Fan Removed 1-3-3 HP_DeviceIndication: Fan Inserted Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication A fan has been inserted. Description Where: is the SMX_Fan.Caption for the fan that has been inserted. AlertingManagedElement WBEM Path of SMX_Fan instance representing the inserted fan.
Property Name Property Implementation ProbableCauseDescription Fan inserted 1-3-4 HP_DeviceIndication: Fan Failed Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication A fan has failed. Description Where: is the SMX_Fan.Caption for the fan that has failed. AlertingManagedElement WBEM Path of SMX_Fan instance representing the failed fan.
1-3-5 HP_DeviceIndication: Fan Repaired Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication A fan has been repaired. The fan is now operating properly. Description Where: is the SMX_Fan.Caption for the fan that has been repaired. AlertingManagedElement WBEM Path of SMX_Fan instance representing the failed fan.
Property Name Property Implementation CIM_Indication PerceivedSeverity 4 (Minor) CIM_AlertIndication A fan has degraded. Description Where: is the SMX_Fan.Caption for the fan that has degraded. AlertingManagedElement WBEM Path of SMX_Fan instance representing the degraded fan. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 9 ProviderName HP Cooling RecommendedActions Check the degraded fan and replace if necessary.
Property Name Property Implementation CIM_AlertIndication A fault tolerant fan is no longer providing cooling for a cooling redundancy set. ) Description Where: represents the SMX_FanRedundancySet.Caption for the redundancy set with reduced redundancy. AlertingManagedElement WBEM Path of SMX_FanRedundancySet instance representing the redundancy set with reduced redundancy.
Property Name Property Implementation CIM_AlertIndication Cooling redundancy has been lost. ) Description Where: represents the SMX_FanRedundancySet.Caption for the redundancy set that lost redundancy. AlertingManagedElement WBEM Path of SMX_FanRedundancySet instance representing the redundancy set where redundancy was lost.
Property Name Property Implementation CIM_AlertIndication Cooling redundancy for the system has been restored. (RedundancySetCaption) Description Where: RedundancySetCaption is SMX_FanRedundancySet.Caption of the cooling redundancy set with restored redundancy. AlertingManagedElement WBEM Path of SMX_FanRedundancySet instance representing the cooling redundancy set with restored redundancy.
Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Cooling redundancy for the system has failed. (RedundancySetCaption) Description Where: RedundancySetCaption is SMX_FanRedundancySet.Caption of the cooling redundancy set with failed redundancy. AlertingManagedElement WBEM Path of SMX_FanRedundancySet instance representing the cooling redundancy set with failed redundancy.
1 HP Insight Management WBEM System Memory Provider The HP Insight Management Web-Based Enterprise Management (WBEM) System Memory provider implements the HP Memory Profile and HP Memory Physical Asset Profile to represent system memory on HP servers. Description This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Memory Profile HP WBEM TC 1.0 HP Memory Physical Asset Profile HP WBEM TC 2.1.0 HP Location Profile HP WBEM TC 1.2.
Configuring the Provider 1-2 This provider does not accept specific configuration adjustments beyond standard HP Insight Management WBEM support. Using the Provider Namespaces Supported by the Provider This provider returns instances in the root/hpq namespace.
• SMX_HostedMemoryRedundancySet • SMX_SystemMemoryModuleSlot • SMX_SystemMemoryBoardSlot • SMX_MemoryModuleOnBoard The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name Property Implementation Enumerator indicating the logical system memory operational status. The status represents the ‘worst-of’ algorithm for all OperationalStatus[0] values reported by physical memory modules in SMX_MemoryModule instances.
Property Name RequestedState Property Implementation 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_Memory DeviceID HPQ:SMX_Memory:000 SystemCreationClassName Same value as SMX_ComputerSystem.CreationClassName property SystemName Same value as SMX_ComputerSystem.
1-2-2 SMX_SystemMemory Class The SMX_SystemMemory class represents an association between SMX_Memory and the computer system that contains the memory. There is one instance of this class. The following table lists the properties implemented.
Property Name Property Implementation Enumerator indicating the memory module operational status. OperationalStatus[0] contains overall memory module status OperationalStatus OperationalStatus[1] contains detailed memory module status (as needed) For details, see “Properties for Memory Module Status”.
Property Name Property Implementation Name of the organization that produced the memory module. Manufacturer For example: HP This property is conditional; it is populated if the data is available. Part number of the memory module. PartNumber This property is conditional; it is populated if the data is available. Manufacturer allocated serial number of the memory module. SerialNumber This property is conditional; it is populated if the data is available.
Property Name MaxMemorySpeed Property Implementation The maximum speed in MHz of PhysicalMemory Enumerator indicating the type of memory module. MemoryType Refer to MOF file for details. PositionInRow Position of memory module in a row. This property is conditional; it is populated if the data is available Enumerator indicating the form factor of the memory module. FormFactor Refer to MOF file for details.
Property Name Property Implementation Enumerator indicating the type of technology of memory module. Technology Refer to MOF file for details. MinimumVoltage This value specifies the minimum voltage needed for the memory module to operate in milivolts.
1-2-4 SMX_MemoryBoard Class The SMX_MemoryBoard class represents a physical memory board on HP servers. There is an instance of this class for each memory module present in the system; empty memory module sockets are not instantiated. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Physical Memory . Caption Refer to “Physical Location” for more information.
Property Name Property Implementation CIM_PhysicalElement CreationClassName SMX_MemoryBoard Tag Opaque key of the form: HPQ:SMX_MemoryBoard: Physical Memory . Description Refer to “Physical Location” for more information. Physical Memory . ElementName Refer to “Physical Location” for more information.
Property Name Property Implementation Indicates the locked state of the memory board: 1 (Not-Applicable), non-AMP systems only Locked 2 (Unlocked) 3 (Locked) NumberOfSockets Number of memory module sockets on this board AvailableMemory Size of memory for this board seen by the operating system in MB TotalMemory Total size of memory for this board in MB 1-2-4-1 Properties for Memory Board Status OperationalStatus[0] OperationalStatus[1] StatusDescriptions[0] StatusDescriptions[1] Condition 0 (Un
OperationalStatus[0] OperationalStatus[1] StatusDescriptions[0] StatusDescriptions[1] Condition on the board. 1-2-5 SMX_RealizesMemoryModule Class The SMX_RealizesMemoryModule class represents an association between SMX_MemoryModule and SMX_Memory. The following table lists the properties implemented.
Property Name Property Implementation CIM_ManagedSystemElement OperationalStatus OperationalStatus[0] = 2 (OK) StatusDescriptions StatusDescriptions[0] = Memory module slot status:OK HealthState 5 (OK) Memory Module . Name Refer to “Physical Location” for more information. CIM_PhysicalElement CreationClassName SMX_MemoryModuleSlot Tag Opaque key of the form: HPQ:SMX_MemoryModuleSlot: Memory Module .
Property Name Property Implementation Note: Not unique on HP Cellular servers. SMX_MemoryModuleSlot 1-2-7 SMX_MemoryBoardSlot Class The SMX_MemoryBoardSlot class represents memory board slots on HP servers. There is an instance of this class for each memory board slot in the system (whether the slot is occupied or not). The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Memory Board Slot .
Property Name Property Implementation Memory Board Slot . ElementName Refer to “Physical Location” for more information. CIM_PhysicalConnector ConnectorLayout 1 (Other) Memory Board Slot . ConnectorDescription Refer to “Physical Location” for more information. CIM_Slot The board/cartridge number where the memory board is located. Number Note: Not unique on HP Cellular servers.
1-2-9 SMX_MemoryBoardInSlot Class The SMX_MemoryBoardInSlot class represents the association between an SMX_MemoryBoard and the SMX_MemoryBoardSlot where it resides. The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Memory Module Socket Location . Caption Refer to “Physical Location” for more information. Memory Module Socket Location . Description Refer to “Physical Location” for more information. Memory Module Socket Location . ElementName Refer to “Physical Location” for more information.
Property Name Property Implementation corresponding LocationInfoDesc index. Array indices will report as many of the following enumerated values as are applicable: 4 (Socket) 5 (Memory Board) LocationInfoDesc 7 (Cabinet) 10 (Cell) 14 (BladeBay) 15 (ProcessorBoard) SMX_MemoryModuleSlotLocation 1-2-12 SMX_MemoryBoardSlotLocation Class The SMX_MemoryBoardSlotLocation class extends the CIM_Location class and represents memory board slot locations on HP servers.
Property Name Property Implementation Memory Board Slot Location . ElementName Refer to “Physical Location” for more information. CIM_Location Name Opaque key of the form: HPQ:SMX_MemoryBoardSlotLocation: . Opaque key. PhysicalPosition For example, for memory board, cartridge, or processor number 1: FF-FF-FF-FF-01-FF-FF-7A HP_Location Opaque key.
Property Name Property Implementation 15 (ProcessorBoard) SMX_MemoryBoardSlotLocation 1-2-13 SMX_MemoryModuleSlotElementLocation Class The SMX_MemoryModuleSlotElementLocation class extends the CIM_ElementLocation class and is used to associate a memory module slot (SMX_MemoryModuleSlot) with its corresponding location (SMX_MemoryModuleSlotLocation). There is an instance of this class for each memory module slot in the system (whether the slot is occupied or not).
Property Name Property Implementation CIM_ElementLocation HP_ElementLocation SMX_MemoryBoardSlotElementLocation Element References SMX_MemoryBoardSlot PhysicalLocation References SMX_MemoryBoardSlotLocation 1-2-15 SMX_SystemMemoryModule Class The SMX_SystemMemoryModule class represents an association between SMX_MemoryModule and SMX_ComputerSystemChassis. There is an instance of this class for each memory module slot on the chassis system board (whether the slot is occupied or not).
CIM_Container HP_SystemMemoryBoard SMX_SystemMemoryBoard GroupComponent References SMX_ComputerSystemChassis PartComponent References SMX_MemoryBoard 1-2-17 SMX_MemoryRedundancySet Class The SMX_MemoryRedundancySet class represents memory board redundancy on HP servers supporting Advanced Memory Protection (AMP). There is one instance of this class on systems supporting AMP. This class is not instantiated on non-AMP systems. The following table lists the properties implemented.
Property Name Property Implementation Represents the type of redundancy currently in operation for the Advanced Memory Protection system. This property corresponds functionally to the property CurrentConfiguration.
Property Name Property Implementation subsystem in MHz AvailableMemory The size of the memory as seen by the operating system in MB TotalMemory Total size of memory as seen by the operating system and memory used for Advanced Memory Protection configurations in MB The current operating mode of the Advanced Memory Protection system. The value in this property corresponds to the value populated in the property TypeOfSet[0].
Property Name Property Implementation An array containing Advanced Memory Protection configurations supported on this system (the CurrentConfiguration and TargetConfiguration properties will contain one of these values). Each indexed position in the array contains one supported configuration. Possible values are: ConfigurationsAvailable Advanced ECC Online Spare Mirrored RAID Lockstep 1-2-18 SMX_MemoryCollection Class The SMX_MemoryCollection class represents physical memory collections on HP servers.
Property Name Property Implementation Enumerator indicating the group operational status of the memory collection. The status is determined as follows: • If an instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined from the property SMX_MemoryRedundancySet.RedundancyStatus. GroupOperationalStatus • If no instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined by the ‘worstof’ algorithm for physical memory boards and memory modules.
- 2 (OK) 0 (Unknown) 0 (Unknown) - 3 (Degraded) 2 (OK) 3 (Degraded) - 3 (Degraded) 3 (Degraded) 3 (Degraded) - 3 (Degraded) 0 (Unknown) 3 (Degraded) - 0 (Unknown) 2 (OK) 0 (Unknown) - 0 (Unknown) 3 (Degraded) 3 (Degraded) - 0 (Unknown) 0 (Unknown) 0 (Unknown) 1-2-19 SMX_HostedMemoryCollection Class The SMX_HostedMemoryCollection class represents an association between SMX_MemoryCollection and the computer system that contains this collection.
1-2-20 SMX_MemberOfMemoryCollection Class The SMX_MemberOfMemoryCollection class represents an association between SMX_MemoryCollection and SMX_MemoryModule or SMX_MemoryBoard. The following table lists the properties implemented.
1-2-22 SMX_HostedMemoryRedundancySet Class The SMX_HostedMemoryRedundancySet class represents an association between SMX_MemoryRedundancySet and the computer system that contains this redundancy set. The following table lists the properties implemented.
1-2-24 SMX_SystemMemoryBoardSlot Class The SMX_SystemMemoryBoardSlot class represents an association between SMX_MemoryBoardSlot and SMX_ComputerSystemChassis. There is an instance of this class for each memory board slot in the chassis (whether the slot is occupied or not). The following table lists the properties implemented.
1-3 Provider Indications Indications Generated by the Provider Generates WBEM indications described in the following sections. Note: 1-3-1 These Indications only apply to Proliant Server.
Property Name Property Implementation OSVersion The operating system version of the computer system generating the indication in the following format: ..
SMX_MemoryIndication: Memory Module Predictive Failure 1-3-2 Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication A memory module has failed or is predicted to fail. Description (MemoryModuleCaption) where MemoryModuleCaption is the SMX_MemoryModule.
1-3-3 SMX_MemoryIndication: Memory Board Error Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication A memory board has an error. (MemoryBoardCaption) Description Where: MemoryBoardCaption is the SMX_MemoryBoard.Caption for the failing memory board.
Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description The Advanced Memory Protection (AMP) system is operating with degraded redundancy. The targeted configuration has degraded or is operating with memory modules that have failed or predicted to fail. (TargetConfiguration/CurrentConfiguration) Where: TargetConfiguration is SMX_MemoryRedundancySet.TargetConfiguration.
SMX_MemoryIndication: Memory Recovered from Degraded Redundancy 1-3-5 Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description The Advanced Memory Protection(AMP) system is operating normally in the targeted configuration. If redundancy was previously degraded, redundancy has been restored. (TargetConfiguration) Where: TargetConfiguration is SMX_MemoryRedundancySet.TargetConfiguration.
1-4 Physical Location Memory Physical Location is a string representing the physical location of a Memory device, such as DIMM, slot, socket, board, or extender. This string should represent the physical location of the device with which an end-user can uniquely locate the device. Most of these strings will be represented in customer documentation, silkscreen labels, or hood tags. The following table lists the properties implemented.