HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

HP Insight Management Power Supply Provider Overview 7
Property Name
Property Implementation
GroupStatusDescriptions[0]
Unknown status for power supplies - if
GroupOperationalStatus[0] is 0 (Unknown);
Power supplies are operating properly if
GroupOperationalStatus[0] is 2 (OK);
Power supplies are degraded if GroupOperationalStatus[0] is 3
(Degraded);
Power supplies have failed if GroupOperationalStatus[0] is 6
(Error)
1-2-3 SMX_PowerRedundancySet Class
The SMX_PowerRedundancySet class is used to model power supply redundancy sets on servers.
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
Caption
Short description of this redundancy set.
For example:
Power Redundancy Set <n>
Where:
<n> represents the number of the redundancy set instance.
Description
Description of this redundancy set
For example:
Power Redundancy Set <n> is collection of fault tolerant power supplies
that provide redundant power
Where: <
n> represents the number of the redundancy set instance.
ElementName
User printable name for this power redundancy set.
For example:
Power Redundancy Set <n>
Where: <
n> represents the number of the redundancy set instance.