HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

HP Insight Management Power Supply Provider Overview 20
Property Name
Property Implementation
PossibleStates
Array may contain the following value:
PossibleStates[0] = “Normal”
CIM_NumericSensor
CurrentReading
Current reading of the power meter
BaseUnits
7 (Watts)
RateUnits
0 (None)
UnitModifier
0
1-2-18 SMX_SystemPowerMeter
SMX_SystemPowerMeter class and associates the HP_ComputerSystem instance with HP_PowerMeter.
Property Name
Property Implementation
GroupComponent
References HP_ComputerSystem
PartComponent
References HP_PowerMeter
1-2-19 SMX_AssociatedPowerMeter
The SMX_AssociatedPowerMeter class associates the HP_PowerSupply instance with HP_PowerMeter
instance.
Property Name
Property Implementation
Dependent
References SMX_PowerSupply
Antecedent
References SMX_PowerMeter
1-2-20 SMX_PowerControllerFirmware
SMX_PowerControllerFirmware is used to model power controller firmware on Servers. Not all systems
support reporting power controller firmware.