HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

HP Insight Management Power Supply Provider Overview 31
Property Name
Property Implementation
Description
A fault tolerant power supply is no longer providing power for a power
redundancy set. RedundancySetCaption
Where: RedundancySetCaption represents the
SMX_PowerRedundancySet.Caption for the redundancy set with
reduced redundancy.
AlertingManagedElement
WBEM Path of SMX_PowerRedundancySet instance representing the
redundancy set with reduced redundancy.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
5
ProviderName
HP Power
RecommendedActions
No action is recommended.
HP_AlertIndication
Summary
Power redundancy reduced
EventCategory
16 (System Power)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription
Power Redundancy has been Reduced
1-3-9 HP_DeviceIndication: Power Supply Redundancy Lost
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
4 (Minor)
CIM_AlertIndication