HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

HP Insight Management Power Supply Provider Overview 33
Property Name
Property Implementation
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description
Power redundancy has been lost. RedundancySetCaption
Where: RedundancySetCaption represents the
SMX
_PowerRedundancySet.Caption
for the redundancy set that failed
redundancy.
AlertingManagedElement
WBEM Path of SMX
_PowerRedundancySet
instance representing the
redundancy set where redundancy failed.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
20
ProviderName
HP Power
RecommendedActions
Check the power supply configuration and check the
status of the power redundancy. Ensure the system is
being powered adequately. Add or replace power supplies
if necessary.
HP_AlertIndication
Summary
Power redundancy set failed
EventCategory
16
(System Power)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription
Power Redundancy Set has Failed