HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

HP Insight Manager WBEM Base Server Provider Overview 28
Property Name
Property Implementation
ProbableCause
111 (Timeout)
ProbableCauseDescription ASR reboot occurred
1-3-6 HP_DeviceIndication: Thermal Reboot Occurred
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description
The system has rebooted from thernal shutdownevent.
AlertType
5 (Device Alert)
EventID 2
ProviderName
HP Recovery
RecommendedActions Replace any failed or removed fans. Insure the air
flow into, out of, and within the system chassis is
not obstructed.
HP_AlertIndication
Summary
Thermal reboot occurred
EventCategory
23 (System Cooling)
ProbableCause
51 (Temperature Unacceptable)
ProbableCauseDescription
Thermal reboot occurred