HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

HP Insight Manager WBEM Base Server Provider Overview 29
1-3-7 HP_DeviceIndication: Fan Failure Reboot Occurred
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description The system has rebooted from fan failure shutdown
event.
AlertType
5 (Device Alert)
EventID
3
ProviderName HP Recovery
RecommendedActions
Replace any failed or removed fans.
HP_AlertIndication
Summary
Fan failure reboot occurred
EventCategory
23 (System Cooling)
ProbableCause
94 (Fan Failure)
ProbableCauseDescription
Fan failure reboot occurred
1-3-8 HP_DeviceIndication: VRM Failure Reboot Occurred
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication