HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

Table 16-79 HP_DeviceIndication: Logical Drive status ERROR
Property name
Property implementation
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
1-2-10 Logical Drive status Degraded
Table 16-80 HP_DeviceIndication: Logical Drive is in a degraded state
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description A logical drive is in a degraded state. Device is still
servicing I/O, but redundancy may be degraded or
lost.
AlertingManagedElement
WBEM Path of Storage Volume
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
103
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions Check status of physical drives. Degraded status may
be caused by failed or missing physical drives, or a
data recovery operation on one or more physical
drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Logical drive degraded state
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription
Logical Drive State Changed to Degraded