HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

HP Insight Management WBEM System Temperature Sensor Provider 6
Property Name
Property Implementation
CIM_ManagedElement
Caption
Temperature Sensor Collection
Description
This is a collection of temperature sensors.
GroupStatusDescription.
Where: GroupStatusDescription represents the value of the
GroupStatusDescriptions[0] property.
ElementName
Temperature Sensor Collection
CIM_SystemSpecificCollection
InstanceID
Unique identifier for this sensor collection instance.
HP_GroupSystemSpecificCollection
GroupOperationalStatus[0]
Represents the most severe sensor group operational status:
2 (OK) if temperatures reported by the sensors are within normal
operating rangeor
if temperatures reported by the sensors have exceeded their non-
critical threshold and has set fans to full speed;
6 (Error)
if temperatures reported by the sensors have exceeded their
non-critical threshold and the system is gracefully shutting down.
GroupStatusDescriptions[0]
Temperatures reported by the sensors are operating
within normal operating range if temperatures reported by the
sensors are within normal operating range;
Temperatures reported by the sensors have exceeded
their non-critical threshold and the fans have been
set to full speed
if temperatures reported by the sensors have
exceeded their threshold and has set fans to full speed;
Temperatures reported by the sensors have exceeded
their threshold and the system is gracefully shutting
down
if temperatures reported by the sensors have exceeded their
threshold and the system is gracefully shutting down.