HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

HP Insight Management WBEM System Temperature Sensor Provider 8
1-3 Provider Indications
Indications Generated
by the Provider
The following tables describe the SMX WBEM System Temperature Sensor Provider
indications that are implemented for HP ProLiant server platforms where available.
1-3-1 HP_AlertIndication: Temperature Sensor Threshold
Exceeded
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication.
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication.
CIM_AlertIndication
Description
A temperature sensor has detected that the
temperature has exceeded the normal operating
range.
<SensorCaption>
Where: <SensorCaption> is the
SMX_NumericSensor.Caption for the sensor that has failed.
AlertingManagedElement
WBEM Path of the SMX_NumericSensor instance representing the
temperature sensor detecting the exceeded threshold.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
1
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Temperature
RecommendedActions
Ensure that the system is adequately ventilated.
Check for proper room temperature and