HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

HP Insight Management WBEM Smart Array Provider 107
Property Name
Property Implementation
DeviceOperationalStatusPrevious
Previous OperationStatus values for Storage Volume
DeviceOperationalStatusPrevious[0]:
SMX_SAStorageVolume.OperationalStatus[0]
DeviceOperationalStatusPrevious[1]:
SMX_SAStorageVolume.OperationalStatus[1]
(This index is only populated if there is additional Vendor unique
status available)
1-3-8 SMX_SAStorageVolumeIndication: Logical Drive Status
Changed to Degraded
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 Warning
IndicationTime
Time of indication
CIM_AlertIndication
Description
A logical drive is in a degraded state. Device
is still servicing I/O but redundancy may be
degraded or lost.
AlertingManagedElement
WBEM Path of SMX_SAStorageVolume class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
103
EventTime
Time of the event or time of the indication if event time