HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

HP Insight Management WBEM Smart Array Provider 119
Property Name
Property Implementation
ProviderVersion
For example: 2.2.0.0
SystemFirmwareVersion
Firmware version of the computer system generating the indication
SystemSerialNumber
Serial number of the computer system generating the indication
SystemProductID
Product ID of the computer system generating the indication
SystemModel
Model name of the computer system generating the indication
SystemGUID
Platform GUID of the computer system generating the indication
SolutionProductModel
Conditional property containing the Solution Name string when running
in a aggregate product environment in the format <aggregate product
family name> v<major>.<minor>.<update>
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note:
When ImpactedDomain is 3 (Enclosure) the properties that follow and
are indicated with an asterisk (*) below will be populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name, if one exists
RackUID *
Rack Unique Identifier, if one exists
SystemVirtualSerialNumber
Conditional property containing the virtual system serial number string
when running in a Virtual Connect environment
SystemVirtualUUID
Conditional property containing the virtual system UUID when running in