HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

Property Name
Property Implementation
Description
Description of this fan module, including ElementName, type and status.
For example:
<ElementName> provides cooling for FanType. <StatusDescription>
Where: <ElementName> represents the value of ElementName, FanType
represents the corresponding string value of the
FanType enumeration
and <
StatusDescription> represents the value of
StatusDescriptions[0].
ElementName
Name of this fan from the name displayed by the MP or iLO and location.
For example:
Fan 1 at CabinetFan=01
CIM_ManagedSystemElement
OperationalStatus[0]
2
(OK) if fan is operating properly;
3 (Degraded) if fan is degraded;
6 (Error) if fan has failed
StatusDescriptions[0]
Description of the status of the fan corresponding to the
OperationalStatus.
For example:
Fan is operating properly if
OperationalStatus[0] is 2 (OK);
Fan is degradedif OperationalStatus[0] is 3 (Degraded)
Fan has failedif OperationalStatus is 6 (Error)
HealthState
5 (OK) if fan is operating properly;
10 (Degraded) if fan is degraded
20 (Major Failure) if fan has failed
Name
Name of this fan module.
For example:
Fan 1 at CabinetFan=01
CIM_PhysicalElement