HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 February 2013 Datasheets

HP Insight Management WBEM System Memory Provider 21
Property Name
Property Implementation
ElementName
Memory Board Slot Location <physical location>.
Refer to “Physical Location” for more information.
CIM_Location
Name
Opaque key of the form: HPQ:SMX_MemoryBoardSlotLocation:
<unique_keys>.
PhysicalPosition
Opaque key.
For example, for memory board, cartridge, or processor number 1:
FF-FF-FF-FF-01-FF-FF-7A
HP_Location
ElementLocationTag
Opaque key.
For example, for memory board, cartridge, or processor number 1:
FF-FF-FF-FF-01-FF-FF-7A
ElementLocationTagDesc
9
(Memory Board) /
13
(Processor Board)
LocationInformation
LocationInformation[0]
text: <x>
Where: <x> is the board/cartridge/processor number
Location information will contain a numeric string representing the unique
location identifier of each object type described by the
corresponding
LocationInfoDesc index.
LocationInfoDesc
Array indices will report as many of the following enumerated values as are
applicable:
5 (Memory Board)
7 (Cabinet)
10 (Cell)
14 (BladeBay)