HP VMware vSphere 5.1 Customized Image Release Notes for September 2012

4 Important notes and recommendations
The drivers and firmware recipe information for enabling hp VirtualConnect support can be
found at the following links: http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA3-3148ENW.pdf
and http://h20000.www2.hp.com/bc/docs/support/SupportManual/c02610285/
c02610285.pdf. The drivers and firmware recipe information for HP ProLiant servers and options
can be found at the following link: http://vibsdepot.hp.com/hpq/recipes.
AMS and Active Health Installation
AMS and Active Health is shipped as part of the HP Custom Image, the HP ESXi Offline Bundle
and the new Agentless Management Service Offline Bundle. The HP Custom Image and the HP
ESXi Offline Bundle also include the HP Insight Management WBEM Providers. The AMS Offline
Bundle only includes the providers required to support online firmware update and SmartArray,
DIMM Status and iLO reporting in vCenter. Customers can manage their ProLiant servers using
Agentless Management without installing the AMS Offline Bundle. Only customers who intend to
manage their ProLiant servers using only Agentless Management and do not need the full set of
HP Insight Management WBEM Providers installed should install the AMS Offline Bundle. See the
Deploying and updating vSphere 5.0 on Proliant servers white paper for more information.
If the customer has ESXi 5.1 and is currently using HP Insight Management WBEM Providers for
ESXi and requires Agentless Management and does not need the full set of providers installed,
they need to perform the following step:
Install the AMS Offline Bundle to replace the HP ESXi Offline Bundle
If the customer has ESXi 5.1 and is currently using Agentless Management and does not have the
full providers installed and wants to move to using HP Insight Management WBEM Providers for
ESXi, they need to perform the following step:
Install the HP ESXi Offline Bundle to replace the AMS Offline Bundle
Missing SNMP traps on HP SIM
This issue, where HP SIM was not receiving the SNMP traps sent by ESXi WBEM Provider has
been fixed in the versions of the HP WBEM provider mentioned below.
HP WBEM Providers for VMware ESXi 5.0 version 02.10.70.
HP ESXi Offline Bundle for VMware ESXi 5.0 version 1.2.
System Memory required for installing ESXi 5.1 Customized Image
VMware ESXi will not install on an HP Gen8 server with 2 GB or less system memory. Although
VMware’s stated minimum installation requirement is 2 GB of system memory, HP’s Gen8 platforms
do not expose enough of the 2 GB of system memory to the operating system, causing the installation
to fail. This issue is resolved by populating the system with more than 2 GB of memory.
sfcb-CIMXML-Pro coredump found during sfcb service shutdown
An intermittent sfcb-CIMXML-Pro core dump is found during SFCB service stop and reboot. This
issue is observed on HP customized ESXi 5.0U1 and ESXi 5.1 images which includes the HP WBEM
Providers. The core dump is found only if this option is enabled using the command /sbin/vsish
-e set /userworld/global/coreDumpEnabled 1 after the system reboot. But an error
message (sfcb-CIMXML-Processor[6210]: Semop failed rc -1, error Invalid
argument) will be seen in then /var/log/syslog.log. This does not impact the working of
HP WBEM providers and can be ignored.
Read cache disabled on Intel C204 Chipset platforms (B120i with PCI ID 8086 1C04 1590 006C)
SAS WWIDs for b120i controllers will be non-unique
7