P00121_-_HP_Smart_Array_Profile

Version 1.3.001 23
6.6 Disk Sparing
HPSA_StorageExtent
HPSA_StorageExtent
HPSA_StorageExtent
HPSA_StoragePool
Concrete Pool
ConcreteComponent
HPSA_StorageRedundancySet
MemberOfCollection
HPSA_StorageExtent
Spare
IsSpare
StorageExtent
StorageRedundancySetStoragePool
Figure 8 HP Smart Array profile: Disk Sparing Class Diagram
The Disk Sparing profile is used to model spare drives for raid sets. All the drives (HPSA_StorageExtent
instances) in a raid shall be associated to an instance of HPSA_StorageRedundancySet via
CIM_MemberOfCollection. Any spare drives (HPSA_StorageExtent) shall be associated to the same
Storage Redundancy Set via the CIM_IsSpare association.
For Smart Array, any raid set may have more than one spare drive and any drive configured as a spare
can be a spare to more than one Storage Redundancy Collection.
When a spare drive is “in use”, the HPSA_StorageExtent will be associated to the failed drive(s) via
CIM_Spared association.
See Section 9.6 for specific use cases.