P00121_-_HP_Smart_Array_Profile

Version 1.3.001 31
HPSA_ArrayController.OperationalStatus
OperationalStatus[0] will be used to indicates the overall health of the controller. Values for
index [0] will be calculated as follows.
Table 3 - HP Smart Array profile: HPSA_ArrayController.OperationalStatus[0]
OperationalStatus[0]
Reason for Status
Error
If the controller status is ERROR or
If the Cache Status is Permanently Disabled or
If the Battery is failed
Degraded
If none Failed conditions are met and
If the Cache Status is Temporarily Disabled or
If the Battery is not fully charged or
If the Capacitor charge is low or
If the capacitor is not attached or
If the capacitor-based cache module backup
operation failed or
If the capacitor-based cache module restore
operation failed or
If the capacitor-based cache module hardware failed
or
If the Capacitor failed to charge or
If the cache is not configured
OK
If none of the Failed and none of the Degraded
conditions are met
HPSA_ArrayController.ADGSupported
Value indicates whether this controller supports Advanced Data Guard Raid level.
Table 4 - HP Smart Array profile: HPSA_ArrayController.ADGSupported
Value
ValueMap
0
Unknown
1
Yes
2
No
3
N/A
HPSA_ArrayController.RebuildPriority
Value indicates the current controller rebuild priority.
Table 5 - HP Smart Array profile: HPSA_ArrayController.RebuildPriority
Value
ValueMap
0
Unknown
1
Low
2
Medium
3
High
4
N/A