P00121_-_HP_Smart_Array_Profile

38 Version 1.3.001
Table 21 - HP Smart Array profile: HPSA_StorageVolume.Accelerator
Value
ValueMap
0
Unknown
1
Enabled
2
Disabled
7.4.3 HPSA_StorageVolume.StripeSize
Value indicates the current stripe size in Bytes for the Logical Volume. Note that this may not have a
value for some configurations (e.g. RAID 0 with a single drive, RAID 1 with only two drives).
7.4.4 HPSA_StorageVolume.PercentComplete
During a rebuild or expand operation, this will indicate progress as a percentage value. Note this value
shall only be populated when a rebuild or expand operation is being performed on this logical volume.
7.4.5 HPSA_StorageVolume.FaultTolerance
Enumeration to indicate which type of raid is currently configured for a logical volume. Supported values
are:
Table 22 - HP Smart Array profile: HPSA_StorageVolume.FaultTolerance
Value
ValueMap
0
Unknown
1
RAID 0
2
RAID 1
3
RAID 1+0
4
RAID 4
5
RAID 5
6
RAID 51
7
RAID 6
8
RAID 50
9
RAID 60
7.4.6 HPSA_StorageVolume.OperationalStatus
OperationalStatus values have been extended to add Smart Array specific values for Logical Volume
status.
The extended values shall be populated in OperationalStatus[1] and the equivalent DMTF defined status
will be populated in OperationalStatus[0] as specified in Table 23. Note these extended values will more
accurately define the storage volume‟s status when in a degraded state.
Table 23 - HP Smart Array profile: HPSA_StorageVolume.OperationalStatus Extended values
Value
ValueMap
OperationalStatus[0]
0x8000
Physical Drive improperly connected
Degraded (3)
0x8001
Expanding
Degraded (3)
0x8002
Overheated
Degraded (3)
0x8003
Overheating
Degraded (3)
0x8004
Interim Recovery
Degraded (3)
0x8005
Not Configured
Degraded (3)
0x8006
Not Yet Available
Degraded (3)
0x8007
Queued For Expansion
Degraded (3)
0x8008
Ready For Recovery
Degraded (3)