P00121_-_HP_Smart_Array_Profile

52 Version 1.3.001
Figure 20 shows an MSA20 external storage system with three SATA drives configured in a RAID 5
configuration. Note in this case the MSA20 does not support controller redundancy so the
HPSA_RedundancySet instance is not modeled.
9.4 Single Pool Multiple Storage Volume
HPSA_ArraySystem:01
SystemDevice
HPSA_StorageVolume:002
Name = VPD pg83
(RAID 1 logical volume)
HPSA_ArrayController:123
ComponentCS
HPSA_PrimordialPool:00
Promordial = “True”
HPSA_StoragePool:01
Promordial = “False” (Concrete)
HPSA_DiskDrive:004
HPSA_DiskDrive:005
SystemDevice
HPSA_StorageExtent:004
HPSA_StorageExtent:005
BasedOn
MediaPresent
MediaPresent
AllocatedFromStoragePool
AllocatedFromStoragePool
HostedStoragePool
HPSA_StorageSetting:002
DataRedundandy = 2
PackageRedundancy = 1
ElementSettingData
ConcreteComponent
HPSA_StorageVolume:004
Name = VPD pg83
(RAID 0 logical volume)
HPSA_StorageSetting:004
DataRedundandy = 1
PackageRedundancy = 0
BasedOn
ElementSettingData
AllocatedFromStoragePool
HostedStoragePool
Figure 21 - HP Smart Array profile: Multiple Storage Volumes