Installation and Reference Guide for HP MPIO Full Featured DSM for MSA1000/1500 (Active-Active) Disk Arrays 3.00.00 (AA-RW8AD-TE, March 2008)
Table 2 Pre-ins talla tion chec klist
Task
Check the contents of the HP MPIO MSA DSM kit and the Fibre Channel hardware to make sure
nothing is missing. If you are missing any component, contact your account repre sentative, or call
the HP Customer Service hotline at (800) 354-9000.
Obtain and review the most current versions of the following documents:
• HP MPIO Full Featured DSM for Windows for MSA1000/1500 (Active-Active) Disk Arrays release
notes
• Installation and configuration information for your system, available at the following web site:
h
ttp://www.hp.com/country/us/eng/prodserv/storage.html
• Supported SAN topologies for HP MPIO MSA DSM, as definedanddescribedinthe
HP StorageWorks SAN design reference guide available at the following web site:
http://h18006.www1.hp.com/products/storageworks/san/documentation.html
CAUTION:
Installing HP MPIO MSA DSM software when the Terminal Server is in execution mode may have
adverse effects on other software products. For detai led information, refer to the Microsoft web site:
h
ttp://support.microsoft.com/default.aspx?scid=kb;en-us;186612.
Installing HP MPIO MSA DSM software
You can install HP MPIO MSA DSM on a stand-alone system or cluster configuration. The procedure that
you follow depends on your current system configuration.
This section describes how to install HP MPIO MSA DSM on the following configurations:
• Installing HP MPIO MSA DSM on stand-alone systems
•InstallingHPMPIOMSADSMonclusterconfigurations
Installing HP MPIO MSA DSM on stand-alone systems
You can install this software prior to attaching the hardware. To install the HP MPIO MSA DSM on
a stand-alone system:
1. Complete the pre-installation checklist (Table 2) and the pre-installation procedure.
2. Ensure that only a single path is connected to the storage devices.
3. Configure the storage sets.
4. Run Launch.exe from the installation location.
5. In the launch window, click HP MPIO Full Featured DSM for MSA1000/1500 (Active-Active) Disk
Arrays.
NOTE:
ForMicrosoftWindowsServer2008–ServerCore(x86andx64),youcanrunLaunch.exe from the
installation location, using the command prompt.
6. Read the information displayed on your screen to complete the installation.
7. Add the redundant pa ths to the storage devices.
12
Installing the HP MPIO Full Featured D evice Specific Module (DSM) for MSA1000/1500 (Active-Active)
Disk Arrays software