Installation and Reference Guide for HP MPIO Full Featured DSM for MSA1000/1500 (Active-Active) Disk Arrays 3.00.00 (AA-RW8AD-TE, March 2008)

Upgrading HP MPIO MSA DSM on cluster congurations
To upgrade HP MPIO MSA DSM from a previous version on each member of a cluster con guration,
complete the st
eps below:
NOTE:
In a cluster conguration, HP MPIO MSA DSM must be upgraded on one node at a time for all the
nodes in the cluster.
1. Complete the pre-installation checklist (Table 2) and the pre-installation procedure.
2. Using Cluster Administr ator:
a. Move all cluster resources owned by the current node to another nod e in the cluster.
b. Pause the current cluster node.
c. Disable failback for all groups c ontaining resources managed by the current node.
3. Upgrade HP MPIO MSA DSM on the current node by following step 2–6 from the procedure
Upgrading HP MPIO MSA DSM on stand-alone systems.
4. Using Cluster Administrator , resume the current cluster node.
NOTE:
Repeat steps 2–4 for all nodes in the cluster.
5. Using Cluster Administrator:
a. Restore failback for all groups containing resources as needed.
b. Redistribute cluster resources as desired.
Migrating from Windows Server 2003 to Windows Ser ver
2008 with HP MPIO MSA DSM
To migrate from Windows Server 2003 to Windows Server 2008 with HP MPIO MSA DSM, complete
the steps b
elow:
1. Back up all user data.
2. Install or Upgrade to HP MPIO MSA DSM 3.00.00, see Chapter 1.
3. Upgrade t
oWindowsServer2008.
4. Double-
click the Batch le (dep ending on your operating system):
•ForWindowsserver2008x86:
<Target_Dir>\x86\Win2k8Upgrade.bat
•ForWind
ows Server 2008 IA64:
<<Target_Dir>\ia64\Win2k8Upgrade.bat
•ForWindowsServer2008x64:
<<Targe
t_Dir>\amd64\Win2k8Upgrade.bat
NOTE:
To upgrade from cluster conguration in Windows Server 2003 to Windows Server 2008, see
h
ttp://support.microsoft.com/kb/935197.
14
Installing the HP MPIO Full Featured D evice Specic Module (DSM) for MSA1000/1500 (Active-Active)
Disk Arrays software