HP MPIO Full Featured DSM for P6x00 family of Disk Arrays 4.04.00 Installation and Reference Guide (757324-001, May 2014)

NOTE:
The P.B.T.L. column shows the device port, bus, target, and LUN.
The RTP column shows the target port information as defined by SCSI-3 specification.
The Controller Port# column shows the controller serial number followed by target port number.
The HBA Slot # is displayed as "0" for iSCSI devices.
hpdsm paths device=1
P.B.T.LRTPHBA
Slot#
StateController StatePath#
3.0.2.3000200084ActiveP8398DXAAQQ013-41
2.0.5.1000200074ActiveP898DXAAQQO101U-22
2.0.6.1000100014ActiveP8398DXAAQQ010-13
3.0.0.1000100014ActiveP8398DXAAQQ010-14
3.0.1.1000200074AvailableP8398DXAAQQ013-35
3.0.2.1000200084AvailableP8398DXAAQQ013-46
4.0.0.1000100013AvailableP8398DXAAQQ010-17
4.0.1.1000200083AvailableP8398DXAAQQ013-48
hpdsm set device policy
Syntax: hpdsm set device=x policy=policy
Syntax: hpdsm set device=all policy=policy
The hpdsm set device policy command sets the load-balancing policy for device x or for
all device, depending on the input parameter specified.
The following example demonstrates the information displayed by the hpdsm set device
policy command.
Example:
hpdsm set device=1 policy=rr
Device Name: HP HSV210
Device Serial No.:600508B400101F6A000070001D950000
Change Load Balance policy (y/n)? y
Load Balance policy changed. Verify by issuing hpdsm devices command.
Example:
hpdsm set device=all policy=rr
Successful for all the devices. Verify by issuing "hpdsm devices" command.
hpdsm set device subset path
Syntax: hpdsm set device=x subset=add/remove path=all
Syntax: hpdsm set device=x subset=add/remove path=y,z
Syntax: hpdsm set device=all subset=add/remove path=all
Syntax: hpdsm set device=all subset=add/remove path=y,z
The hpdsm set device=x subset=add/remove path=y,z command enables or disables
subset setting for device x and adds or removes y,z to or from the subset, as shown in the following
example:
hpdsm set device policy 17