HP MPIO Full Featured DSM for SAN Virtualization Services Platform 4.01.00 installation and reference guide (5697-0237, January 2010)

NOTE:
After the upgrade, reboot the host and present back all the SVSP devices.
Upgrading HP MPIO SVSP DSM on a clustered system
To upgrade HP MPIO SVSP DSM from a previous version to the current version on a clustered system,
complete the following steps:
NOTE:
On a clustered system, HP MPIO SVSP DSM must be upgraded on one node at a time for all nodes
in the cluster.
1. Complete the pre-installation checklist (Table 2) and the pre-installation procedure, see Preparing
for installation.
2. Using Cluster Administrator:
a. Move all cluster resources owned by the current node to another node in the cluster.
b. Pause the current cluster node.
c. Disable failback for all groups containing resources managed by the current node.
3. Upgrade HP MPIO SVSP DSM on the current node by following steps 26 from the procedure
provided for Upgrading HP MPIO SVSP DSM on a stand-alone system.
4. Using Cluster Administrator, resume the current cluster node.
NOTE:
Repeat steps 24 for all the nodes in a cluster.
5. Using Cluster Administrator:
a. Restore failback for all groups containing resources, as needed.
b. Redistribute cluster resources as desired.
NOTE:
After the upgrade, reboot the host and present back all the SVSP devices.
Migrating HP MPIO SVSP DSM from Windows Server 2003
to Windows Server 2008
To migrate HP MPIO SVSP DSM from Windows Server 2003 to Windows Server 2008, complete
the following steps:
1. Back up all user data.
2. Install or upgrade to HP MPIO SVSP DSM 4.01.00. For more information, see Chapter 1.
Installing the HP MPIO Full Featured DSM for SAN Virtualization Services Platform14