® Programmable HEPA Air Purifier Model 30225 & 37225 (remote included) Replacement Filter Information MODEL 30225 37225 PRE-FILTER 30901 37901 HEPA FILTER 30940 37940 www.hunterfan.
Table of Contents Safety Instructions .................................................................................................. 3 Introduction ............................................................................................................ 3 Description of Air Filtration System How the Air Purifier Works ..................................................................... 4 Air Purifier Components .........................................................................
SAFETY INSTRUCTIONS IMPORTANT! READ ALL INSTRUCTIONS BEFORE USING THIS AIR PURIFIER. 1. This air purifier is designed for use on a flat level floor and may not work properly on an uneven floor. ALWAYS place the air purifier on a firm level floor. ALWAYS place the air purifier at least six (6) inches away from walls and heat sources such as stoves, radiators, or heaters. 2. Place the air purifier in an area that is out of the reach of children. 3.
Description of Air Filtration System How the QuietFlo HEPA Air Purifier System Works ® As the air is pulled into the purifier, the activated carbon pre-filter absorbs odors and catches large particles. Then, the air travels through the HEPA filter where the smaller particles are collected. Finally, the clean purified air is released back into the room. Dust & Irritants Pollen & Allergens Carbon Pre-Filter Odors Bacteria Pet Hair & Dander True HEPA Filter 99.97% – .3 Microns Fig.
Description of Air Filtration System Display and Control Keys The display and control keys allow for easy operation of the air purifier. ON/OFF: Turns the unit on and off. PROGRAM: Allows you to enter program mode and define user programs. (User programming on pg. 15.) UP/DOWN KEYS (+/-): Adjusts the blower speed and changes values in clock setting and programming modes. DAY/TIME: Used to set the day and time. (Setting day and time on pg. 13.) DISPLAY: Selects the clock, pre-filter, or filter display.
Operation Initial Operation This section provides basic instructions on the use of your air purifier. After following these initial directions, please continue reading this booklet to learn how to operate the more advanced features of your air purifier. Basic Operation of the Air Purifier: 1. Take the air purifier out of the box and remove the clear plastic protective bag. Place the unit on a firm level floor. 2.
Operation Adjusting Day and Time: (For example, Wednesday at 3:45 pm) 1. To set the day or time, press the DAY/TIME key. All display features except the day and time will go blank and the hour will flash. Fig. 7 2. Use the UP/DOWN keys to adjust the hour. Tapping the key will advance the hour by increments of one. Holding down the key will change the hour rapidly. Note the AM/PM indicator as you cycle through a 24 hour period. 3. Press the DAY/TIME key again. Now, the minutes will be flashing.
Operation Remote Operation For your convenience, a remote control is provided with this air purifier. The remote may be used to turn the air purifier on or off and adjust the fan speed. Operating the Air Purifier with the remote: 1. Install two AAA batteries (UM-4 or IEC R03 or equivalent). Refer to the graphics in the battery compartment for proper orientation of the batteries. 2. To use the remote, point it at the air purifier, then press and release the appropriate key.
Operation Display Modes Your air purifier has 3 display modes – Clock Display, Pre-Filter Display, and Filter Display. When the unit is running, the display also provides additional information about the settings of the air purifier. The features for each mode and how to change modes is described below. Clock Display: The default mode of the unit is the Clock Display. In this mode, the day indicator, time, and AM/PM indicator will be lit. If military time has been chosen (See Setting Day and Time, pg.
Operation Manual and Auto Operating Modes Your Hunter Air Purifier has two distinct operating modes – Manual and Auto. The Manual Mode allows you to override the control programs that have been set and to hold the settings until you adjust them. In Manual Mode, the automatic programs are not active. You select whether the unit is on or off and choose the blower speed. In Auto Mode, your air purifier is capable of running 4 separate programs for the weekdays and an additional 4 programs for the weekend.
Operation Override of Auto Mode You can use two different methods to override Auto Mode. If you choose temporary override, the air purifier will run at the temporary setting until the next scheduled program change. Permanent override will remain in effect until you return the unit to auto mode. When in Auto Mode, remote use acts as a temporary override.
Operation Filter Run-Time Counters The pre-filter and filter are critical to the proper operation of the air purifier. To help you know when to change the filters, your Hunter Air Purifier has Filter Run-Time Counters that will monitor the number of hours your filters have been in use. Although the exact life of the filters depends on the environment, the table below gives typical usage times of the filters.
Programming Setting Day and Time Setting the correct day and time allows the programs to work effectively and provides a clock for your reference. Although the instructions for setting the day and time are listed under Initial Operation, they are repeated below for your convenience. Adjusting Day and Time: (For example, Wednesday at 3:45 pm) DAY TIME 1. To set the day or time, press the DAY/TIME key. All display features except the day and time will go blank and the hour will flash. Fig. 19 2.
Programming NOTES: • The clock flashes when the time has not been set. • At any time while you are setting the Day/Time, you can press the PROGRAM key to toggle between AM/PM format and military time format. • To quickly exit the Day/Time setting mode, you can press the DISPLAY key or wait 15 seconds without pressing any keys. • The time displayed will be frozen in Day/Time setting mode; however, the internal clock is still running.
Programming User Programming User programming allows you to set when the air purifier is on and what blower speed to use. You may define up to 4 programs for the weekdays and up to 4 programs for the weekend. Before starting the programming process, first you should determine what times and blower speeds will best fit your needs. Use the charts below to organize and record the programs that you desire. Use a pencil so you can revise your records each time you change the programs.
Programming 41674-01 16
Programming Reviewing Programs You may want to review the programs to confirm that the settings are still acceptable. The following steps show you how to review the programs. To review programs: PROG 1. With the air purifier On, press and hold the PROGRAM key. After 2 seconds, the display will advance through the 4 programs for weekdays and then the 4 programs for the weekend. You must hold the PROGRAM key as the display reviews the programs. 2.
Programming Resetting the Air Purifier In the unusual situation that the unit or the display is exhibiting erratic behavior, you may want to reset the air purifier. Since you will lose all of your programmed settings when the unit is reset, you should consult the Troubleshooting section (pg. 22) of the manual to resolve the problem before using the Reset Feature. When the unit is reset, the clock, day of the week, and programs will default to their factory settings and the unit will turn off.
Air Purifier Maintenance Cleaning Your Air Purifier Proper maintenance of your Hunter Air Purifier will help ensure years of trouble free service. Follow these steps to properly maintain your air purifier: 1. Approximately every 90 days, the outside of the unit should be cleaned with a soft, damp cloth. 2. If needed, the front grill can be removed from the unit and cleaned with soapy water. Simply remove the pre-filter before exposing the grill to water. 3.
Air Purifier Maintenance 6. Install the grill back onto the unit. First, line up the tabs on the bottom of the grill with the openings on the purifier base and then push the top of the grill forward until it is closed. 7. Plug in the air purifier. NOTE: This unit will not operate unless the grill is in the correct position. The display will read “door” if the grill is not attached properly. DISP FILT RST 8.
Air Purifier Maintenance 6. Plug in the unit. NOTE: This unit will not operate unless the grill is in the correct position. The display will read “door” if the grill is not attached properly. DISP FILT RST 7. To reset the filter counter, press the DISPLAY key until the filter counter is displayed. Then, hold the FILTER RESET key for 2 seconds. The filter counter will return to zero and resume counting. Fig.
Troubleshooting Problem Solutions 1. No Display • Confirm that the unit is plugged in. • Check the installation of the front grill. • Reset the air purifier. (See Resetting the Air Purifier on pg. 18.) 2. Display reads “door.” • The front grill is not attached properly. Remove grill from unit and re-attach. (See Initial Operation on pg. 6.) 3. Program number is flashing. • Unit is in temporary program override mode. Refer to Override of Auto Mode on pg. 11. 4. Programs are not running.
Warranty Hunter Fan Company QuietFlo True HEPA Air Purifier 5 YEAR LIMITED WARRANTY ® The Hunter Fan Company makes the following limited warranty to the original residential user or consumer purchaser of the QuietFlo ® True HEPA Air Purifier: If any part of your QuietFlo® True HEPA Air Purifier motor or control panel fails during the first five (5) years from the date of installation due to a defect in material or workmanship, we will provide a replacement Air Purifier free of charge.
Warranty Other Home Comfort Products from Hunter The Care-Free Humidifier ™ Programmable Thermostat To learn more about Hunter Fan Company products, please see our Web page at: www.hunterfan.